Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY › from 2021.07
RM38G0E _57 Power Source / Network _100627 POWER DISTRIBUTION _0468585 INTEGRATION RELAY A

POWER DISTRIBUTION  INTEGRATION RELAY  INSTALLATION  


CAUTION / NOTICE / HINT

COMPONENTS (INSTALLATION)
E465045N01
6.448,0.208 6.771,0.208 false 6.51,0.51 6.76,0.51 false 0.573,0.854 0.917,0.854 false 1.438,1.375 1.635,1.375 false 6.26,0.031 6.542,0.385 0.281,0.354 18 false 3 6.313,0.365 6.594,0.719 0.281,0.354 18 false 4 1.927,1.135 2.208,1.49 0.281,0.354 18 false 1 0.375,0.708 0.656,1.063 0.281,0.354 18 false 2

Procedure Part Name Code
Z101186

Z101188

Z101187

1 SEMICONDUCTOR POWER INTEGRATION ECU 82644 (Click here) - -
2 NO. 1 RELAY BLOCK COVER 82661 - - -
3 CABLE TO NEGATIVE BATTERY TERMINAL - - - -
4 INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL - - - (Click here)

CAUTION / NOTICE / HINT

HINT:
·

Use the same procedure for RHD and LHD vehicles.

·

The procedure listed below is for LHD vehicles.



PROCEDURE

Hide 82644 1.INSTALL SEMICONDUCTOR POWER INTEGRATION ECU

a.
E465160C01
0.427,0.063 0.708,0.417 0.281,0.354 18 false i 2.677,1.115 2.885,1.479 0.208,0.365 18 true ii 4.25,0.104 4.479,0.469 0.229,0.365 18 true iii
V113147

Install in this Direction - -


i.

Attach the claw to connect the lever connector.

NOTICE:

Be sure to connect the lever connector securely.



ii.

Connect the connector.


iii.

Attach the claw to install the semiconductor power integration ECU as shown in the illustration.



Hide 82661 2.INSTALL NO. 1 RELAY BLOCK COVER

Hide 3.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Hide 4. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART