Home › Power Source / Network › F33A-FTV (BATTERY / CHARGING) › CHARGING SYSTEM › from 2021.07
RM38G0E _57 Power Source / Network _106328 F33A-FTV BATTERY / CHARGING _0489033 CHARGING SYSTEM C

F33A-FTV BATTERY / CHARGING  CHARGING SYSTEM  P062049  Generator Control Circuit Internal Electronic Failure  


DESCRIPTION

The alternator performs self-diagnosis of its internal circuits to detect malfunctions (open or short circuits).

The ECM receives the result via LIN communication and stores a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Note
P062049 Generator Control Circuit Internal Electronic Failure All of the following conditions are met (1 trip detection logic):
·

Ignition switch ON.

·

Except during engine cranking.

·

Battery voltage is 10.5 V or higher.

·

No malfunction in the LIN communication system.

·

Open or short in EXC circuit, or abnormal waveform for PH circuit.


Generator assembly Charge warning is displayed SAE: P0620

WIRING DIAGRAM

A485854E02
3.135,1.688 3.594,1.885 0.458,0.198 10 false B39 3.146,1.833 4.344,2.219 1.198,0.385 10 false Battery State Sensor Assembly 6.125,3.229 6.583,3.427 0.458,0.198 10 false ECM 4.24,4.792 5.135,5.021 0.896,0.229 10 false IC Regulator 4.01,5.771 5.438,5.99 1.427,0.219 10 false Generator Assembly 1.344,0.896 2.302,1.094 0.958,0.198 10 false BATT-S NO. 1 2.365,2.99 2.76,3.177 0.396,0.188 10 false ALT 3.188,0.74 3.5,0.938 0.313,0.198 10 false +B 3.198,1.438 3.813,1.635 0.615,0.198 10 false RBAT 3.875,1.042 4.333,1.24 0.458,0.198 10 false LIN 5.823,1.063 6.281,1.26 0.458,0.198 10 false LIN 5.833,2.229 6.146,2.427 0.313,0.198 10 false E1 4.729,3.75 5.188,3.948 0.458,0.198 10 false LIN 4.51,4.021 4.969,4.219 0.458,0.198 10 false LIN 3.469,3.74 3.625,3.938 0.156,0.198 10 false B 3.854,4.01 4.01,4.208 0.156,0.198 10 false B 3.854,4.604 4.115,4.802 0.26,0.198 10 false PH 3.854,5.188 4.271,5.365 0.417,0.177 10 false EXC 3.844,5.406 4.25,5.583 0.406,0.177 10 false GND 3.292,3.479 3.906,3.677 0.615,0.198 10 false C57 4.49,3.49 4.948,3.688 0.458,0.198 10 false C53 3.667,3.49 3.823,3.688 0.156,0.198 10 false 1 4.844,3.5 5,3.698 0.156,0.198 10 false 2 3,0.615 3.156,0.813 0.156,0.198 10 false 3 3.01,1.313 3.167,1.51 0.156,0.198 10 false 1 4.208,0.865 4.365,1.063 0.156,0.198 10 false 2 5.469,1.052 6.083,1.25 0.615,0.198 10 false B70 5.469,2.219 6.083,2.417 0.615,0.198 10 false B70 5.5,0.813 5.813,1.01 0.313,0.198 10 false 13 5.5,1.969 5.813,2.167 0.313,0.198 10 false 10 0.719,4.49 1.302,4.917 0.583,0.427 10 false Battery 0.698,6.427 2.375,6.625 1.677,0.198 10 false : LIN Communication Line 1.323,1.635 2.281,1.833 0.958,0.198 10 false BATT-S NO. 2 0.229,0.083 2.354,0.385 2.125,0.302 10 false w/ Stop and Start System:

A485855E02
0.583,3.99 1.219,4.354 0.635,0.365 10 false Battery 2.594,0.833 3.208,1.031 0.615,0.198 10 false ALT 3.469,2.635 4.083,2.833 0.615,0.198 10 false B 4.875,2.646 5.49,2.844 0.615,0.198 10 false LIN 3.646,2.396 4.26,2.594 0.615,0.198 10 false 1 4.99,2.385 5.604,2.583 0.615,0.198 10 false 2 4.313,3.615 5.406,3.833 1.094,0.219 10 false IC Regulator 4.094,4.677 5.74,4.917 1.646,0.24 10 false Generator Assembly 1.063,5.385 2.927,5.615 1.865,0.229 10 false : LIN Communication Line 4.615,2.375 5.229,2.573 0.615,0.198 10 false C53 5.948,0.677 6.563,0.875 0.615,0.198 10 false LIN 5.563,0.667 6.177,0.865 0.615,0.198 10 false B70 5.583,1.542 6.198,1.74 0.615,0.198 10 false B70 5.938,1.563 6.552,1.76 0.615,0.198 10 false E1 6.177,2.135 6.729,2.448 0.552,0.313 10 false ECM 5.594,0.427 6.208,0.625 0.615,0.198 10 false 13 5.615,1.313 6.229,1.51 0.615,0.198 10 false 10 3.833,3.542 4.448,3.74 0.615,0.198 10 false PH 3.833,4.083 4.448,4.281 0.615,0.198 10 false EXC 3.833,4.344 4.448,4.542 0.615,0.198 10 false GND 3.813,2.906 4.427,3.104 0.615,0.198 10 false B 4.635,2.896 5.25,3.094 0.615,0.198 10 false LIN 3.26,2.385 3.875,2.583 0.615,0.198 10 false C57 0.115,0.125 2.688,0.365 2.573,0.24 10 false w/o Stop and Start System: 0.792,1.281 1.802,1.51 1.01,0.229 10 false MAIN R/B 0.969,0.802 1.583,1 0.615,0.198 10 false *1 0.49,1.229 1.104,1.427 0.615,0.198 10 false *2 1.615,1.219 2.229,1.417 0.615,0.198 10 false *2 0.708,4.677 1.875,4.948 1.167,0.271 10 false *1: for LHD 0.708,5 1.875,5.271 1.167,0.271 10 false *2: for RHD

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.