77871A 1.REMOVE UREA PUMP
35000 2.REMOVE AUTOMATIC TRANSMISSION ASSEMBLY
77840D 3.DISCONNECT NO. 2 UREA TUBE WITH HEATER ASSEMBLY
|
|
Detach the lock claw by lifting up the cover.
Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the No. 2 urea tube with heater assembly.
If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.
Be sure to disconnect the urea tube connector by hand.
Check for foreign matter in the urea pump and around the urea tube with heater connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the No. 2 urea tube with heater assembly and urea tube with heater connector.
Put the urea pump and urea tube with heater connector ends in plastic bags to prevent damage and foreign matter contamination.
Disconnect the connector from the urea tube with heater assembly.
77862A 4.DISCONNECT NO. 2 UREA TANK BRACKET
77910 5.DISCONNECT UREA TANK FILLER PIPE ASSEMBLY
|
|
Detach the clamp and disconnect the the urea tank filler pipe from the urea tank sub-assembly.
Detach the claw of the retainer of the urea tube connector, pull up the retainer and disconnect the urea tube connector from the urea tank sub-assembly.
If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tube connector.
Be sure to disconnect the urea tube connector by hand.
Check for foreign matter in the urea tank sub-assembly and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tube connector.
Put the urea tank sub-assembly and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.
Detach the claw of the retainer of the urea tube connector, pull up the retainer and disconnect the urea tube connector from the urea tank sub-assembly.
If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the urea tube connector.
Be sure to disconnect the urea tube connector by hand.
Check for foreign matter in the urea tank sub-assembly and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tube connector.
Put the urea tank sub-assembly and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.
82161 6.DISCONNECT FLOOR WIRE
77801A 7.REMOVE UREA TANK SUB-ASSEMBLY
77840A 8.REMOVE UREA TUBE WITH HEATER ASSEMBLY
77885 9.REMOVE UREA TANK HARNESS
77852 10.REMOVE NO. 2 UREA TANK PROTECTOR
77862A 11.REMOVE NO. 2 UREA TANK BRACKET