| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 1 | NO. 2 NITROGEN OXIDES SENSOR | 89463D | ( ) |
- | - |
| 2 | NO. 1 SENSOR BRACKET | 89439D | - | - | - |
|
N*m (kgf*cm, ft.*lbf): Specified torque | * | For use with SST |
| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 3 | WIRING HARNESS CLAMP BRACKET | 82715W | |||
| 4 | NO. 1 NITROGEN OXIDES SENSOR | 89463C | - | - | |
| 5 | NO. 3 EXHAUST MANIFOLD HEAT INSULATOR | 17169 | - | - | - |
| 6 | INTAKE PIPE INSULATOR | 17117A | - | - | - |
|
N*m (kgf*cm, ft.*lbf): Specified torque | ● | Non-reusable part |
| * | For use with SST | - | - |
Do not reuse the sensor which has been dropped or taken on a strong impact.
Do not pull and twist the sensor wire strongly.
89463D 1.INSTALL NO. 2 NITROGEN OXIDES SENSOR
| *a | Torque Wrench Fulcrum Length | - | - |
Temporarily put the No. 2 nitrogen oxides sensor on the frame.
Temporarily tighten the No. 2 nitrogen oxides sensor probe.
Install the No. 2 nitrogen oxides sensor with the 2 nuts.
Tighten the No. 2 nitrogen oxides sensor probe.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 49.2 N*m (502 kgf*cm, 36 ft.*lbf)
Clamp the sensor wire and the connect the No. 2 nitrogen oxides sensor connector.
89439D 2.INSTALL NO. 1 SENSOR BRACKET
82715W 3.INSTALL WIRING HARNESS CLAMP BRACKET
89463C 4.INSTALL NO. 1 NITROGEN OXIDES SENSOR
| *a | Fulcrum length | - | - |
Temporarily tighten the No. 1 nitrogen oxides sensor probe to the front No. 2 exhaust pipe sub-assembly.
Install the No. 1 nitrogen oxides sensor with the 2 bolts.
Clamp the No. 1 nitrogen oxides sensor wire to the bracket.
Tighten the No. 1 nitrogen oxides sensor.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 49.2 N*m (502 kgf*cm, 36 ft.*lbf)
Connect the No. 1 nitrogen oxides sensor connector.
17169 5.INSTALL NO. 3 EXHAUST MANIFOLD HEAT INSULATOR
17117A 6.INSTALL INTAKE PIPE INSULATOR