Home › Engine / Hybrid System › 1GR-FE (ENGINE CONTROL) › SFI SYSTEM › 2014.08–2016.08
RM25T0E _51 Engine / Hybrid System _029758 1GR-FE ENGINE CONTROL _0135343 SFI SYSTEM J

1GR-FE ENGINE CONTROL  SFI SYSTEM  Fuel Pump Control Circuit  


DESCRIPTION

When the engine is cranked, an STA signal is sent to the ECM from ignition switch terminal ST1. When the STA and NE signals are received by the ECM, Tr1 inside the ECM turns on and current flows through the coil of the circuit opening relay. As a result, the relay switches on and the fuel pump operates with power from the fuel pump relay. While the NE signal is being sent (while the engine is running), the fuel pump continues to operate since Tr1 in the ECM continues to stay on (the circuit opening relay is on). The speed of the fuel pump is regulated at two speeds (high and low) according to the state of the engine (cranking, light load or heavy load). When Tr2 inside the ECM is off, the fuel pump operates at high speed. When Tr2 turns on during idling or light loads, current flows to the fuel pump through the fuel pump resistor and the fuel pump operates at low speed.

In the case that the vehicle is equipped with a sub fuel tank, when the STA signal and NE signal are input to the ECM, Tr1 turns on and current flows through the coil of the circuit opening relay. As a result, the relay switches on, power is supplied to the fuel pump via the fuel pump relay and pump select relay, and the fuel pump operates.

When the fuel tank select switch is off, the contact inside the pump select relay connects the power supply to the main fuel pump and the main fuel pump operates.

When the fuel tank select switch is on, the contact inside the pump select relay connects the power supply to the sub fuel pump and the sub fuel pump operates.

WIRING DIAGRAM

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.PERFORM ACTIVE TEST USING GTS (OPERATE CIRCUIT OPENING RELAY)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump / Speed.

Powertrain > Engine and ECT > Active Test
Tester Display
Control the Fuel Pump / Speed
50004 234 5

e.

Check the relay operation while operating it using the GTS.

Standard:

Operating noise can be heard from the relay.



Result:
Proceed to
OK
NG



OK

2.INSPECT RELAY (FUEL PMP)

NG

7.CHECK ECM POWER SOURCE CIRCUIT
2.INSPECT RELAY (FUEL PMP)

Result:
Proceed to
OK
NG



OK

3.INSPECT TERMINAL VOLTAGE (FUEL PMP RELAY TERMINAL)

NG

3.INSPECT TERMINAL VOLTAGE (FUEL PMP RELAY TERMINAL)
A288659C01
1.438,0.469 1.729,0.646 0.292,0.177 10 false *1 0.531,1.323 0.823,1.5 0.292,0.177 10 false *2
*1 Engine Room R/B Assembly
*2 FUEL PMP


a.

Remove the FUEL PMP relay from the Engine Room Relay Block Assembly.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
FUEL PMP relay terminal 1 - Body ground Cranking 11 to 14 V
FUEL PMP relay terminal 3 - Body ground Cranking 11 to 14 V



Result:
Proceed to
OK
NG



OK

4.INSPECT FUEL PUMP RESISTOR

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (C/OPN RELAY - FUEL PMP RELAY, EFI MAIN RELAY)

4.INSPECT FUEL PUMP RESISTOR

Inspect fuel pump resistor.

Click hereEngine / Hybrid System>1GR-FE (FUEL)>FUEL PUMP RESISTOR>INSPECTION

Result:
Result Proceed to
OK (w/o Fuel Sub Tank) A
OK (w/ Fuel Sub Tank) B
NG C



A

5.INSPECT FUEL PUMP

B

10.INSPECT FUEL PUMP (MAIN AND SUB)

C

5.INSPECT FUEL PUMP

b.

Result:
Proceed to
OK
NG



OK

6.CHECK HARNESS AND CONNECTOR (FUEL PMP RELAY - FUEL PUMP RESISTOR - FUEL PUMP)

NG

6.CHECK HARNESS AND CONNECTOR (FUEL PMP RELAY - FUEL PUMP RESISTOR - FUEL PUMP)
a.

Remove the FUEL PMP relay from the Engine Room Relay Block Assembly.


b.

Disconnect the fuel pump resistor connector.


c.

Disconnect the fuel pump connector.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for 90L Tank
Tester Connection Condition Specified Condition
FUEL PMP relay terminal 5 - A17-1 Always Below 1 Ω
A17-2 - T3-1 Always Below 1 Ω
FUEL PMP relay terminal 4 - T3-1 Always Below 1 Ω
T3-2 - Body ground Always Below 1 Ω
FUEL PMP relay terminal 5 or A17-1 - Body ground Always 10 kΩ or higher
A17-2 or T3-1 - Body ground Always 10 kΩ or higher
FUEL PMP relay terminal 4 or T3-1 - Body ground Always 10 kΩ or higher


for 130 L Tank
Tester Connection Condition Specified Condition
FUEL PMP relay terminal 5 - A17-1 Always Below 1 Ω
A17-2 - T8-1 Always Below 1 Ω
FUEL PMP relay terminal 4 - T8-1 Always Below 1 Ω
T8-6 - Body ground Always Below 1 Ω
FUEL PMP relay terminal 5 or A17-1 - Body ground Always 10 kΩ or higher
A17-2 or T8-1 - Body ground Always 10 kΩ or higher
FUEL PMP relay terminal 4 or T8-1 - Body ground Always 10 kΩ or higher


Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK ECM POWER SOURCE CIRCUIT

Result:
Proceed to
OK
NG



OK

8.INSPECT RELAY (C/OPN)

NG

REPAIR OR REPLACE ECM POWER SOURCE CIRCUIT

8.INSPECT RELAY (C/OPN)

Result:
Proceed to
OK
NG



OK

9.CHECK HARNESS AND CONNECTOR (C/OPN RELAY - IGNITION SWITCH ASSEMBLY, ECM)

NG

REPLACE RELAY (C/OPN)

9.CHECK HARNESS AND CONNECTOR (C/OPN RELAY - IGNITION SWITCH ASSEMBLY, ECM)
a.

Disconnect the ECM connector.


b.

Remove the C/OPN relay from the Engine Room Relay Block Assembly.


c.

Disconnect the ignition switch assembly connector.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for LHD
Tester Connection Condition Specified Condition
L21-6 (IG2) - C/OPN relay terminal 1 Always Below 1 Ω
C/OPN relay terminal 2 - I84-7 (FC) Always Below 1 Ω
L21-6 (IG2) or C/OPN relay terminal 1 - Body ground Always 10 kΩ or higher
C/OPN relay terminal 2 or I84-7 (FC) - Body ground Always 10 kΩ or higher

for RHD
Tester Connection Condition Specified Condition
L21-6 (IG2) - C/OPN relay terminal 1 Always Below 1 Ω
C/OPN relay terminal 2 - A29-7 (FC) Always Below 1 Ω
L21-6 (IG2) or C/OPN relay terminal 1 - Body ground Always 10 kΩ or higher
C/OPN relay terminal 2 or A29-7 (FC) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.INSPECT FUEL PUMP (MAIN AND SUB)
a.

Remove the sub fuel pump and main fuel pump.

Click hereEngine / Hybrid System>1GR-FE (FUEL)>FUEL PUMP>REMOVAL


b.

Inspect the sub fuel pump and main fuel pump.

Click hereEngine / Hybrid System>1GR-FE (FUEL)>FUEL PUMP>INSPECTION


Result:
Proceed to
OK
NG



OK

11.CHECK HARNESS AND CONNECTOR (FUEL PMP RELAY - FUEL PUMP RESISTOR - PMP SELECT RELAY)

NG

11.CHECK HARNESS AND CONNECTOR (FUEL PMP RELAY - FUEL PUMP RESISTOR - PMP SELECT RELAY)
a.

Remove the FUEL PMP relay from the Engine Room Relay Block Assembly.


b.

Disconnect the fuel pump resistor connector.


c.

Remove the PMP SELECT relay from the Engine Room Relay Block Assembly.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
FUEL PMP relay terminal 5 - A17-1 Always Below 1 Ω
A17-2 - PMP SELECT relay terminal 3 Always Below 1 Ω
FUEL PMP relay terminal 4 - PMP SELECT relay terminal 3 Always Below 1 Ω
FUEL PMP relay terminal 5 or A17-1 - Body ground Always 10 kΩ or higher
A17-2 or PMP SELECT relay terminal 3 - Body ground Always 10 kΩ or higher
FUEL PMP relay terminal 4 or PMP SELECT relay terminal 3 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

12.INSPECT RELAY (PMP SELECT)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

12.INSPECT RELAY (PMP SELECT)

Result:
Proceed to
OK
NG



OK

13.CHECK PMP SELECT RELAY OPERATION

NG

REPLACE RELAY (PMP SELECT)

13.CHECK PMP SELECT RELAY OPERATION
a.

Turn the ignition switch to ON.


b.

Check whether operating sounds can be heard when the fuel tank select switch is pressed.

OK:

Operating sounds can be heard from relay.



Result:
Proceed to
OK
NG



OK

14.CHECK HARNESS AND CONNECTOR (PMP SELECT RELAY - FUEL PUMP)

NG

19.INSPECT FUEL TANK SELECT SWITCH
14.CHECK HARNESS AND CONNECTOR (PMP SELECT RELAY - FUEL PUMP)
a.

Remove the PMP SELECT relay from the Engine Room Relay Block Assembly.


b.

Disconnect the sub fuel pump and main fuel pump connectors.


c.

Disconnect the fuel tank solenoid return valve connector.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
PMP SELECT relay terminal 4 - C31-1 Always Below 1 Ω
PMP SELECT relay terminal 5 - X2-1 Always Below 1 Ω
C31-2 - Body ground Always Below 1 Ω
X2-2 - Body ground Always Below 1 Ω
PMP SELECT relay terminal 4 or C31-1 - Body ground Always 10 kΩ or higher
PMP SELECT relay terminal 5 or X2-1 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

15.INSPECT FUEL TANK SOLENOID RETURN VALVE

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

15.INSPECT FUEL TANK SOLENOID RETURN VALVE
a.

Result:
Proceed to
OK
NG



OK

16.CHECK HARNESS AND CONNECTOR (PMP SELECT RELAY - FUEL TANK SOLENOID RETURN VALVE)

NG

16.CHECK HARNESS AND CONNECTOR (PMP SELECT RELAY - FUEL TANK SOLENOID RETURN VALVE)
a.

Disconnect the fuel tank solenoid return valve connector.


b.

Remove the PMP SELECT relay from the Engine Room Relay Block Assembly.


c.

Disconnect the sub fuel pump connectors.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
PMP SELECT relay terminal 5 - W11-1 Always Below 1 Ω
W11-2 - Body ground Always Below 1 Ω
PMP SELECT relay terminal 5 or W11-1 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

17.INSPECT RELAY (SUB PMP)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

17.INSPECT RELAY (SUB PMP)

Result:
Proceed to
OK
NG



OK

18.CHECK HARNESS AND CONNECTOR (SUB PMP RELAY - IGNITION SWITCH ASSEMBLY, FUEL PUMP (SUB), EFI MAIN RELAY)

NG

18.CHECK HARNESS AND CONNECTOR (SUB PMP RELAY - IGNITION SWITCH ASSEMBLY, FUEL PUMP (SUB), EFI MAIN RELAY)
a.

Remove the SUB PMP relay from the Engine Room Relay Block Assembly.


b.

Disconnect the ignition switch assembly connector.


c.

Disconnect the sub fuel pump connector.


d.

Remove the EFI MAIN relay from the Engine Room Relay Block Assembly.


e.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
SUB PMP relay terminal 1 - L21-3 (ST1) Always Below 1 Ω
SUB PMP relay terminal 5 - X2-1 Always Below 1 Ω
SUB PMP relay terminal 3 - EFI MAIN relay terminal 3 Always Below 1 Ω
SUB PMP relay terminal 2 - Body ground Always Below 1 Ω
SUB PMP relay terminal 1 or L21-3 (ST1) - Body ground Always 10 kΩ or higher
SUB PMP relay terminal 5 or X2-1 - Body ground Always 10 kΩ or higher
SUB PMP relay terminal 3 or EFI MAIN relay terminal 3 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

19.INSPECT FUEL TANK SELECT SWITCH

Result:
Proceed to
OK
NG



OK

20.CHECK HARNESS AND CONNECTOR (PMP SELECT RELAY - FUEL TANK SELECT SWITCH ASSEMBLY, IGNITION SWITCH)

NG

REPLACE FUEL TANK SELECT SWITCH

20.CHECK HARNESS AND CONNECTOR (PMP SELECT RELAY - FUEL TANK SELECT SWITCH ASSEMBLY, IGNITION SWITCH)
a.

Remove the PMP SELECT relay from the Engine Room Relay Block Assembly.


b.

Disconnect the fuel tank select switch connector.


c.

Disconnect the ignition switch assembly connector.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
PMP SELECT relay 1 - L21-6 (IG2) Always Below 1 Ω
PMP SELECT relay 2 - L8-3 Always Below 1 Ω
L8-4 - Body ground Always Below 1 Ω
PMP SELECT relay 1 or L21-6 (IG2) - Body ground Always 10 kΩ or higher
PMP SELECT relay 2 or L8-3 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR