After replacing the exhaust manifold converter sub-assembly (DPF catalyst), clear the thermal deterioration data stored in the ECM.
Click hereEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>INITIALIZATION
Connect the GTS to the DLC3.
Start the engine and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Catalytic Converter.
Take a snapshot of the following Data List items.
A snapshot can be used to compare vehicle data from the time of the malfunction to normal data and is very useful for troubleshooting. The data in the list below is that of a normal vehicle, but as the data varies between individual vehicles, this data should only be used for reference.
Check the Data List at idling and at 4000 rpm with no load after the engine is warmed up.
| Proceed to |
|---|
| NEXT |
NEXT
Check Catalyst Differential Press in the snapshot taken in procedure 1 when the engine was running at 4000 rpm with no load.
| Result | Proceed to |
|---|---|
| Catalyst Differential Press is more than 0.56 | A |
| Except above | B |
A
B
Replace the front exhaust pipe assembly (DPF catalytic converter).
Click hereEngine / Hybrid System>1VD-FTV (INTAKE / EXHAUST)>EXHAUST PIPE (for 5 Door)>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Catalyst Record Clear.
| Tester Display |
|---|
| Catalyst Record Clear |
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs.
Turn the ignition switch off and wait for 30 seconds or more.
Turn the ignition switch to ON and wait for 10 seconds or more.
Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher.
Maintain the maximum possible engine speed under no load for 10 seconds to blow out all soot from the inside of the exhaust pipe.
If only a low engine speed is continuously maintained, soot may accumulate at the end of the catalyst.
When soot accumulates at the end of the catalyst, it may not be possible to perform PM forced regeneration control normally.
Enter the following menus: Powertrain / Engine and ECT/ Active Test / Activate the DPF Rejuvenate (PM)
Perform the Active Test.
| Tester Display |
|---|
| Activate the DPF Rejuvenate (PM) |
Be careful of the exhaust pipes and surrounding areas, as they become extremely hot when performing PM forced regeneration.
After 10 minutes has passed with the engine coolant temperature at 80°C (176°F) or higher during PM regeneration, check the value of Exhaust Temperature B1S3.
PM forced regeneration takes 15 to 40 minutes to finish.
The time it takes to complete PM forced regeneration changes depending on "PM Accumulation Ratio" and the vehicle operating conditions.
If the value of "Catalyst Differential Press" increases too much during the PM forced regeneration, the failsafe function activates and PM forced regeneration is stopped.
Perform PM forced regeneration control until the display on the multi-information display turns off.
If actions such as depressing the accelerator pedal or clutch pedal, etc. are performed during PM forced regeneration, PM forced regeneration stops. If PM forced regeneration stops, it is necessary to perform it again.
PM forced regeneration control is not complete until the display on the combination meter turns off.
| Result | Proceed to |
| Exhaust Temperature Sensor B1S3 does not reach 500°C (932°F)* | A |
| Exhaust Temperature Sensor B1S3 reaches 500°C (932°F) or higher | B |
*: If the Exhaust Temperature Sensor B1S3 is not 500°C (932°F) or more, the exhaust fuel addition fuel injector may be blocked.
B
A
Click hereEngine / Hybrid System>1VD-FTV (EMISSION CONTROL)>EXHAUST FUEL ADDITION INJECTOR (for DPF)>REMOVAL