The mass air flow (MAF) meter uses a platinum hot wire. The mass air flow meter consists of a platinum hot wire, a temperature sensor and a control circuit installed in a plastic housing. The mass air flow meter hot wire and temperature sensor (located in the intake air by-pass of the housing) detect changes in the intake air temperature.
The hot wire is maintained at the predetermined temperature by controlling the current flow through the hot wire. This current flow is then used as the output voltage of the mass air flow meter.
The circuit is constructed so that the platinum hot wire and temperature sensor provide a bridge circuit, with the power transistor controlled so that the potential of A and B remains equal to maintain the predetermined temperature.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0100 | Mass or Volume Air Flow Circuit | Open or short in mass air flow meter circuit for more than 3 seconds with engine speed at 4000 rpm or less (1 trip detection logic) |
·
Open or short in mass air flow (MAF) meter circuit
·
Mass air flow meter
·
ECM |
Comes on | DTC stored |
| P0102 | Mass or Volume Air Flow Circuit Low Input | Open in mass air flow meter circuit for more than 3 seconds with engine speed at 4000 rpm or less (1 trip detection logic) |
·
Open or short in mass air flow (MAF) meter circuit
·
Mass air flow meter
·
ECM |
Comes on | DTC stored |
| P0103 | Mass or Volume Air Flow Circuit High Input | Short in mass air flow meter circuit for more than 3 seconds with engine speed at 4000 rpm or less (1 trip detection logic) |
·
Open or short in mass air flow (MAF) meter circuit
·
Mass air flow meter
·
ECM |
Comes on | DTC stored |
After confirming DTC P0100, P0102 or P0103, check the mass air flow ratio in the "Powertrain / Engine and ECT / Data List / MAF" menu using the GTS.
| Air Flow Value (gm/sec.) | Malfunction |
|---|---|
| Approximately 0.0 |
·
Open in mass air flow meter power source circuit
·
Open or short in VG circuit |
| 174.0 or more | Open in EVG circuit |
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o EGR System)>REGISTRATION) and initialization (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o EGR System)>INITIALIZATION).
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Connect the GTS to the DLC3.
Start the engine and turn the GTS ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.
| Tester Display |
|---|
| MAF |
Read the value.
| Result | Proceed to |
|---|---|
| 0.0 | A |
| 174.0 or more | B |
| Between 1 and 173.0* | C |
*: The value should change when the throttle valve is opened or closed.
A
B
C
| *a | Front view of wire harness connector (to Mass Air Flow Meter) |
Disconnect the mass air flow meter connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C41-1 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector (to Mass Air Flow Meter) |
| *b | Front view of wire harness connector (to ECM) |
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C41-3 (VG) - C39-72 (VG) | Always | Below 1 Ω |
| C41-2 (E2G) - C39-118 (EVG) | Always | Below 1 Ω |
| C41-3 (VG) or C39-72 (VG) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
| OK |
| NG |
OK
NG
Inspect the mass air flow meter.
Click hereEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>MASS AIR FLOW METER(w/o DPF)>ON-VEHICLE INSPECTION
| Proceed to |
| OK |
| NG |
OK
NG
Disconnect the mass air flow meter connector.
Remove the MAIN relay from the engine room R/B assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C41-1 (+B) - MAIN relay terminal 3 | Always | Below 1 Ω |
| C41-1 (+B) or MAIN relay terminal 3 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
| OK |
| NG |
OK
Click hereEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o EGR System)>ECM Power Source Circuit
NG
| *a | Front view of wire harness connector (to Mass Air Flow Meter) |
Disconnect the mass air flow meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C41-2 (E2G) - Body ground | Ignition switch ON | Below 1 Ω |
| Proceed to |
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector (to Mass Air Flow Meter) |
| *b | Front view of wire harness connector (to ECM) |
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C41-3 (VG) - C39-72 (VG) | Always | Below 1 Ω |
| C41-2 (E2G) - C39-118 (EVG) | Always | Below 1 Ω |
| C41-3 (VG) or C39-72 (VG) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
| OK |
| NG |
OK
NG