Auxiliary battery power is supplied to the BATT terminal of the shift control ECU. Back-up power is supplied even the ignition switch turned off.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1761A2 | Gear Shift Control Module "A" System Voltage Low | With auxiliary battery voltage 10 V or higher, BATT terminal voltage (ECU recognition value) is below 1 V continuously for 3 seconds or more
(1 trip detection logic) |
·
Shift control ECU ·
Wire harness or connector |
·
Master Warning -
Comes on ·
Multi-information Display Error Message -
Displayed |
EV | A |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the All Readiness check procedure.
Click hereDrivetrain>Q710 (HYBRID TRANSMISSION / TRANSAXLE)>ELECTRONIC SHIFT LEVER SYSTEM>UTILITY
Turn the ignition switch to ON and wait for 5 seconds or more.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
The vehicle is equipped with a shift control supply. Therefore, ensure there is no power being supplied to the vehicle when disconnecting or reconnecting the connector of the shift control ECU and when removing or installing the shift control ECU.
Click hereDrivetrain>Q710 (HYBRID TRANSMISSION / TRANSAXLE)>ELECTRONIC SHIFT LEVER SYSTEM>PRECAUTION
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Check the connector connections and contact pressure of the relevant terminals for the shift control ECU connectors.
The connectors are connected securely and there are no contact pressure problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the D93 shift control ECU connector.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D93)Location & Routingewd_type=routing;type=c;code=D93 Click Connector(D93)Instrument Panel>Instrument Panel Wire>Shift Control ECUewd_type=component;type=c;code=D93;pinno=1 |
||
| D93-1 (BATT) - Body ground | Ignition switch off | 8 to 15.4 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the D93 shift control ECU connector.
OK
NG
Pre-procedure1
Disconnect the D93 shift control ECU connector.
Remove the P CON MAIN fuse from the luggage room relay block.
| *1 | Luggage Room Relay Block | *2 | P CON MAIN Fuse |
| *a | Front view of wire harness connector
(to Shift Control ECU) |
- | - |
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D93)Location & Routingewd_type=routing;type=c;code=D93 Click Connector(D93)Instrument Panel>Instrument Panel Wire>Shift Control ECUewd_type=component;type=c;code=D93;pinno=1 |
||
| P CON MAIN fuse terminal 2 - D93-1 (BATT) | Always | Below 1 Ω |
| P CON MAIN fuse terminal 2 or D93-1 (BATT) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the D93 shift control ECU connector.
Install the P CON MAIN fuse.
OK
NG
Pre-procedure1
| *1 | Luggage Room Relay Block |
| *2 | P CON MAIN Fuse |
Remove the P CON MAIN fuse from the luggage room relay block.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the cable from the positive (+) auxiliary battery terminal.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| P CON MAIN fuse terminal 1 - Auxiliary battery positive (+) cable | Always | Below 1 Ω |
| P CON MAIN fuse terminal 1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Connect the cable to the positive (+) auxiliary battery terminal.
Connect the cable to the negative (-) auxiliary battery terminal.
Install the P CON MAIN fuse.
OK
NG
Charge the auxiliary battery.
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
Turn the ignition switch to ON.
Procedure1
Check for DTCs and freeze frame data and then write them down.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off.
NEXT
Pre-procedure1
Turn the ignition switch to ON.
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off.
Leave the vehicle as is for 60 seconds or more.
Do not connect the GTS.
Do not depress the brake pedal.
Do not open/close any of the doors.
NEXT
Pre-procedure1
Turn the ignition switch to ON and wait for 5 seconds or more.
Procedure1
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P1761A2 is not output | A |
| P1761A2 is output | B |
Post-procedure1
Turn the ignition switch off.
A
B