The EV control ECU monitors the voltage of the HV battery. The EV control ECU stops compressor control and stores this DTC when the monitored voltage is outside the specified range.
This DTC will be stored as a history DTC. Compressor control may not resume unless the ignition switch is turned off.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B1471 | A/C Inverter High Voltage Power Resource System Malfunction | Diagnosis condition:
Ignition switch ON (READY) Malfunction status:
Open or short in A/C inverter high voltage power resource system Detection time:
None |
·
CAN communication system ·
Hybrid control system ·
No. 1 EV battery pack wire ·
Compressor with motor assembly |
Memorized | Air Conditioner | B |
After removing the EV battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
After removing the EV battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Inspect the fuses for circuits related to this system before performing the following procedure.
After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
The hybrid control system and air conditioning system output DTCs separately. Perform troubleshooting for the hybrid control system first if DTCs from these systems are output simultaneously.
Using the GTS, check if the CAN communication system is functioning normally.
| Result | Proceed to |
|---|---|
| CAN communication system DTCs are not output | A |
| CAN communication system DTCs are output | B |
A
B
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
Check if hybrid control system DTCs are output.
EV control system DTCs are not output.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
A
B
Be sure to wear insulated gloves.
Pre-procedure1
Remove the No. 1 EV battery pack wire.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(b3,b4)Location & Routingewd_type=routing;type=c,c;code=b3,b4 Click Connector(b3)Engine Compartment>FC Cooling Water Pump Cable>Compressor with Motor Assemblyewd_type=component;type=c;code=b3;pinno=2,1 Click Connector(b4)Engine Compartment>FC Cooling Water Pump Cable>FC Converter Assemblyewd_type=component;type=c;code=b4;pinno=2,1 |
||
| b3-2 (P) - b4-2 (P) | Always | Below 1 Ω |
| b3-1 (N) - b4-1 (N) | Always | Below 1 Ω |
| b3-2 (P) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG