If a malfunction is detected in the power supply circuit, the No. 2 skid control ECU (brake actuator assembly) power source voltage drops, or there is insufficient voltage to operate the main relay, the No. 2 skid control ECU (brake actuator assembly) will store a DTC.
If the auxiliary battery voltage is temporarily low, this DTC may be stored.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority | Note |
|---|---|---|---|---|---|---|
| C123D14 | IG2 Circuit Short to Ground or Open | When communication with the EV control ECU is normal or the vehicle speed exceeds 10 km/h, no voltage (below 3.0 V and either PT1 is on or PT2 is on) is applied to the IG2 terminal and the power source voltage (exceeding 9.5 V) is applied to the IG1 terminal continuously for 4 seconds or more. | ·
Open or short in IG2 circuit ·
Improperly connected connector, deformation or corrosion of terminals ·
No. 2 skid control ECU (brake actuator assembly) |
Brake/EPB | A | Output ECU: No. 2 skid control ECU (brake actuator assembly) |
| Vehicle Condition | |||||
|---|---|---|---|---|---|
| Pattern 1 | Pattern 2 | Pattern 3 | Pattern 4 | ||
| Diagnosis Condition | When communication with the EV control ECU is normal | ○ | ○ | - | - |
| The vehicle speed is exceeds 10 km/h (6 mph) | - | - | ○ | ○ | |
| Malfunction Status | No voltage (below 3.0 V and either PT1 is on) is applied to the IG2 terminal and the power source voltage (exceeding 9.5 V) is applied to the IG1 terminal continuously | ○ | - | ○ | ○ |
| No voltage (below 3.0 V and either PT2 is on) is applied to the IG2 terminal and the power source voltage (exceeding 9.5 V) is applied to the IG1 terminal continuously | - | ○ | - | ○ | |
| Detection Time | 4 seconds or more. | 4 seconds or more. | 4 seconds or more. | 4 seconds or more. | |
| Number of Trips | 1 trip | 1 trip | 1 trip | 1 trip | |
DTC will be output when conditions for either of the patterns in the table above are met.
Refer to DTC C137BA2.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM>C137BA2
Inspect the fuses for circuits related to this system before performing the following procedure.
Before performing troubleshooting, make sure to confirm that the auxiliary battery voltage is normal.
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
After replacing the No. 2 skid control ECU (brake actuator assembly), perform "Calibration".
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM>UTILITY
Procedure1
Make sure that there is no looseness at the locking part and the connecting part of the connector.
The connector is securely connected.
Pre-procedure1
Disconnect the A6 No. 2 skid control ECU (brake actuator assembly) connector.
Procedure2
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Pre-procedure2
Turn the ignition switch to ON.
Procedure3
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A6)Location & Routingewd_type=routing;type=c;code=A6 |
||
| A6-15 (IG2) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
for LHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for RHD)>REMOVAL
NG