MALFUNCTION DESCRIPTION
These DTCs are stored when the motor temperature sensor output is abnormal. The cause of this malfunction may be one of the following:
Internal motor temperature sensor malfunction
Open or short in motor temperature sensor
The connectors are not connected properly
Foreign matter or water on the connector terminals
Open or short in wire harness
If any of these DTCs are stored, the motor temperature sensor is malfunctioning and the self-protection function may not operate. Therefore under certain high load driving condition, the temperature of the motor (MG2) becomes high. If the self-protection function does not operate, the motor (MG2) may malfunction and cause the vehicle to enter fail-safe mode.
Refer to the description for DTC P0A2A11.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P0A2A1C | Drive Motor "A" Temperature Sensor Voltage Out of Range | After a long soak, the value of the motor (MG2) temperature sensor is different from the value of the other temperature sensors.
(2 trip detection logic) |
·
Wire harness or connector ·
FCV with motor transaxle assembly (Motor temperature sensor) ·
EV control ECU |
Master Warning:
Comes on |
EV | A |
| P0A2A1F | Drive Motor "A" Temperature Sensor Circuit Intermittent | Sudden change in motor temperature sensor output or hunting:
Unusual sudden change in motor temperature sensor output occurs and offset condition continues for a certain period of time, or unusual change in motor temperature sensor output occurs repeatedly. (1 trip detection logic) |
·
Wire harness or connector ·
FCV with motor transaxle assembly (Motor temperature sensor) ·
EV control ECU |
Master Warning:
Comes on |
EV | A |
| DTC No. | Data List |
|---|---|
| P0A2A1C
P0A2A1F |
·
Motor Temperature ·
FC Air Compressor Motor Temperature |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off.
Leave the vehicle as is for 5 minutes or more and then check the values of the Data List items "FC Air Compressor Motor Temperature", "Motor Temperature" and "Inverter Coolant Temperature".
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON and wait for 5 seconds or more.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to DTC P0A2A11.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A2A1C or P0A2A1F is output and DTCs other than the DTCs in the table below are output | A |
| Only P0A2A1C or P0A2A1F is output | B |
| Relevant DTC | |
|---|---|
| P0A2A11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
| P0A2A15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Pre-procedure1
Disconnect the G14*1 or A14*2 EV control ECU connector.
*1: for LHD
*2: for RHD
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Rear view of wire harness connector
(to EV Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G14)Location & Routingewd_type=routing;type=c;code=G14 Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECUewd_type=component;type=c;code=G14;pinno=21,31 |
||
| G14-21 (MMT) - G14-31 (MMTG) | Ignition switch off | 0.3 to 2100 kΩ |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A14)Location & Routingewd_type=routing;type=c;code=A14 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=21,31 |
||
| A14-21 (MMT) - A14-31 (MMTG) | Ignition switch off | 0.3 to 2100 kΩ |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the G14*1 or A14*2 EV Control ECU connector.
*1: for LHD
*2: for RHD
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Pre-procedure1
Disconnect the GG2 No. 3 floor wire connector.
Disconnect the G14*1 or A14*2 EV control ECU.
*1: for LHD
*2: for RHD
Procedure1
Measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *a | Front view of wire harness connector
(No. 3 Floor Wire Connector) |
*b | Rear view of wire harness connector
(to EV Control ECU) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(GG2,G14)Location & Routingewd_type=routing;type=w,c;code=GG2,G14 Click Connector(GG2)Body>Floor Wire / No. 3 Floor Wire>No. 3 Floor Wire and Floor Wireewd_type=component;type=w;code=GG2;pinno=13,14 Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECUewd_type=component;type=c;code=G14;pinno=21,31 |
||
| GG2-13 (MMT) - G14-21 (MMT) | Ignition switch off | Below 1 Ω |
| GG2-14 (MMTG) - G14-31 (MMTG) | Ignition switch off | Below 1 Ω |
| GG2-13 (MMT) or G14-21 (MMT) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| GG2-14 (MMTG) or G14-31 (MMTG) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(GG2,A14)Location & Routingewd_type=routing;type=w,c;code=GG2,A14 Click Connector(GG2)Body>Floor Wire / No. 3 Floor Wire>No. 3 Floor Wire and Floor Wireewd_type=component;type=w;code=GG2;pinno=13,14 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=21,31 |
||
| GG2-13 (MMT) - A14-21 (MMT) | Ignition switch off | Below 1 Ω |
| GG2-14 (MMTG) - A14-31 (MMTG) | Ignition switch off | Below 1 Ω |
| GG2-13 (MMT) or A14-21 (MMT) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| GG2-14 (MMTG) or A14-31 (MMTG) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the G14*1 or A14*2 EV control ECU.
*1: for LHD
*2: for RHD
Reconnect the GG2 No. 3 floor wire connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Pre-procedure1
Disconnect the GG2 No. 3 floor wire connector.
Disconnect the G154 motor temperature sensor connector.
Procedure1
| *a | Front view of wire harness connector
(to Motor Temperature Sensor) |
| *b | Front view of wire harness connector
(No. 3 Floor Wire Connector) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(GG2,G154)Location & Routingewd_type=routing;type=w,c;code=GG2,G154 Click Connector(GG2)Body>Floor Wire / No. 3 Floor Wire>No. 3 Floor Wire and Floor Wireewd_type=component;type=w;code=GG2;pinno=13,14 Click Connector(G154)Body>Floor Wire / No. 3 Floor Wire>FCV Transaxle with Motor Assemblyewd_type=component;type=c;code=G154;pinno=14,2 |
||
| GG2-13 (MMT) - G154-14 (MMT) | Ignition switch off | Below 1 Ω |
| GG2-14 (MMTG) - G154-2 (MMTG) | Ignition switch off | Below 1 Ω |
| GG2-13 (MMT) or G154-14 (MMT) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| GG2-14 (MMTG) or G154-2 (MMTG) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the G154 motor temperature sensor connector.
Reconnect the GG2 No. 3 floor wire connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Disconnect the AG2 No. 2 floor wire connector.
Disconnect the A14 EV control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(AG2,A14)Location & Routingewd_type=routing;type=w,c;code=AG2,A14 Click Connector(AG2)Instrument Panel>Front Compartment Main Wire>Front Compartment Main Wire and Floor Wireewd_type=component;type=w;code=AG2;pinno=21,2 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=21,31 |
||
| AG2-21 (MMT) - A14-21 (MMT) | Ignition switch off | Below 1 Ω |
| AG2-2 (MMTG) - A14-31 (MMTG) | Ignition switch off | Below 1 Ω |
| AG2-21 (MMT) or A14-21 (MMT) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| AG2-2 (MMTG) or A14-31 (MMTG) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Reconnect the A14 EV control ECU.
Reconnect the AG2 No. 2 floor wire connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Disconnect the AG2 No. 2 floor wire connector.
Disconnect the GG2 No. 3 floor wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(AG2,GG2)Location & Routingewd_type=routing;type=w,w;code=AG2,GG2 Click Connector(AG2)Instrument Panel>Front Compartment Main Wire>Front Compartment Main Wire and Floor Wireewd_type=component;type=w;code=AG2;pinno=21,2 Click Connector(GG2)Body>Floor Wire / No. 3 Floor Wire>No. 3 Floor Wire and Floor Wireewd_type=component;type=w;code=GG2;pinno=13,14 |
||
| AG2-21 (MMT) - GG2-13 (MMT) | Ignition switch off | Below 1 Ω |
| AG2-2 (MMTG) - GG2-14(MMTG) | Ignition switch off | Below 1 Ω |
| AG2-21 (MMT) or GG2-13 (MMT) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| AG2-2 (MMTG) or GG2-14 (MMTG) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Reconnect the GG2 No. 3 floor wire connector.
Reconnect the AG2 No. 2 floor wire connector.
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Pre-procedure1
| *A | for LHD |
| *B | for RHD |
Disconnect the AG2 No. 2 floor wire connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(AG2,GG2)Location & Routingewd_type=routing;type=w,w;code=AG2,GG2 Click Connector(AG2)Instrument Panel>Front Compartment Main Wire>Front Compartment Main Wire and Floor Wireewd_type=component;type=w;code=AG2;pinno=21 Click Connector(GG2)Body>Floor Wire / No. 3 Floor Wire>No. 3 Floor Wire and Floor Wireewd_type=component;type=w;code=GG2;pinno=2 |
||
| AG2-21 (MMT) - GG2-2 (MMTG) | Ignition switch off | 0.3 to 2100 kΩ |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the AG2 No. 2 floor wire connector.
OK
NG
Pre-procedure1
Disconnect the GG2 No. 3 floor wire connector.
Procedure1
| *a | Front view of wire harness connector
(No. 3 Floor Wire Connector) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(GG2)Location & Routingewd_type=routing;type=w;code=GG2 Click Connector(GG2)Body>Floor Wire / No. 3 Floor Wire>No. 3 Floor Wire and Floor Wireewd_type=component;type=w;code=GG2;pinno=13,14 |
||
| GG2-13 (MMT) - GG2-14 (MMTG) | Ignition switch off | 0.3 to 2100 kΩ |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the GG2 No. 3 floor wire connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Proceed to |
|---|
| OK |
| NG |
OK
NG