Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0463852 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P260031  Motor/Generator Coolant Pump "A" Control Circuit No Signal  


DESCRIPTION

The EV control ECU detects drive motor temperature based on signals from the drive motor temperature sensor and activates the OIL PMP MTR relay and oil pump with motor assembly.

The EV control ECU monitors NOPM signals from the oil pump driver and detects malfunctions.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P260031 Motor/Generator Coolant Pump "A" Control Circuit No Signal When the OIL PMP MTR relay is on, the NOPM pulse signal is not output.
(2 trip detection logic)
·

FCV with motor transaxle assembly

·

Oil pump with motor assembly

·

OIL PMP MTR relay

·

OIL PMP fuse

·

EV control ECU

·

Wire harness or connector


Master Warning:
Comes on
EV A

Related Data List
DTC No. Data List
P260031
·

Target Motor/Generator Cooling Oil Pump Motor Duty

·

Motor/Generator Cooling Oil Pump Motor Revolution

·

Motor/Generator Cooling Oil Pump Motor Power Relay Request



HINT:

The oil pump with motor assembly cannot be activated only with the OIL PMP MTR relay on. It is activated after receiving the command signals (OPM1) from the EV control ECU.


CONFIRMATION DRIVING PATTERN

HINT:

After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Enter the following menus: Powertrain / EV / Active Test / Control the Motor/Generator Cooling Oil Pump.

3.

According to the display on the GTS, perform the Active Test and set the duty to 90%.

HINT:

The Active Test cannot be performed if the duty ratio is set to 50% or lower or 95% or higher, or if the ambient temperature is -11°C (12.2°F) or lower.


4.

According to the display on the GTS, read the Data List and check that the value of "Motor/Generator Cooling Oil Pump Motor Revolution" is between 450 rpm and 7000 rpm.

5.

Enter the following menus: Powertrain / EV / Utility / All Readiness.

6.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




WIRING DIAGRAM

for LHD:
A466199E03
1.417,1.708 2.375,1.917 0.958,0.208 10 false OIL PMP MTR 1.406,1.344 1.656,1.604 0.25,0.26 10 false 2 2.115,0.938 2.365,1.198 0.25,0.26 10 false 5 1.396,0.948 1.646,1.208 0.25,0.26 10 false 3 2.104,1.344 2.521,1.729 0.417,0.385 10 false 1 0.781,0.927 1.031,1.188 0.25,0.26 10 false 1 1.031,0.927 1.281,1.188 0.25,0.26 10 false 2 0.688,1.208 1.417,1.469 0.729,0.26 10 false OIL PMP 3.302,2.063 3.719,2.448 0.417,0.385 10 false 1 3.271,0.948 3.688,1.333 0.417,0.385 10 false 4 3.49,1.042 3.906,1.427 0.417,0.385 10 false L 3.5,2.219 3.917,2.604 0.417,0.385 10 false OPG 4.271,0.958 4.802,1.333 0.531,0.375 10 false NOPM 4.302,2.094 4.833,2.469 0.531,0.375 10 false OPM1 4.792,0.958 5.042,1.219 0.25,0.26 10 false 2 4.781,2.094 5.031,2.354 0.25,0.26 10 false 3 3.333,2.625 3.75,3.01 0.417,0.385 10 false G155 3.333,2.781 5.281,3.063 1.948,0.281 10 false Oil Pump with Motor Assembly 5.219,4.01 5.594,4.26 0.375,0.25 10 false A17 5.198,3.479 5.573,3.729 0.375,0.25 10 false G14 5.198,2.188 5.573,2.438 0.375,0.25 10 false G14 5.208,1.042 5.583,1.292 0.375,0.25 10 false G14 5.25,0.823 5.604,1.156 0.354,0.333 10 false 10 5.313,3.802 5.667,4.135 0.354,0.333 10 false 4 5.302,3.25 5.656,3.583 0.354,0.333 10 false 9 5.26,1.969 5.615,2.302 0.354,0.333 10 false 15 5.573,0.948 6.104,1.323 0.531,0.375 10 false NOPM 5.563,2.083 6.094,2.458 0.531,0.375 10 false OPM1 5.563,3.396 6.094,3.771 0.531,0.375 10 false OPM2 5.573,4.01 6.104,4.385 0.531,0.375 10 false E1 5.75,4.458 6.875,4.719 1.125,0.26 10 false EV Control ECU 0.083,2.833 1.615,3.073 1.531,0.24 10 false From Auxiliary Battery

for RHD:
A466199E04
1.417,1.708 2.375,1.917 0.958,0.208 10 false OIL PMP MTR 1.406,1.344 1.656,1.604 0.25,0.26 10 false 2 2.115,0.938 2.365,1.198 0.25,0.26 10 false 5 1.396,0.948 1.646,1.208 0.25,0.26 10 false 3 2.104,1.344 2.521,1.729 0.417,0.385 10 false 1 0.781,0.927 1.031,1.188 0.25,0.26 10 false 1 1.031,0.927 1.281,1.188 0.25,0.26 10 false 2 0.688,1.208 1.417,1.469 0.729,0.26 10 false OIL PMP 3.281,2.063 3.698,2.448 0.417,0.385 10 false 1 3.271,0.948 3.688,1.333 0.417,0.385 10 false 4 3.479,1.042 3.896,1.427 0.417,0.385 10 false L 3.469,2.198 3.885,2.583 0.417,0.385 10 false OPG 4.26,0.948 4.792,1.323 0.531,0.375 10 false NOPM 4.302,2.073 4.833,2.448 0.531,0.375 10 false OPM1 4.792,0.958 5.042,1.219 0.25,0.26 10 false 2 4.781,2.094 5.031,2.354 0.25,0.26 10 false 3 3.333,2.646 3.75,3.031 0.417,0.385 10 false G155 3.323,2.802 5.271,3.083 1.948,0.281 10 false Oil Pump with Motor Assembly 5.208,4 5.583,4.25 0.375,0.25 10 false A17 5.208,3.469 5.583,3.719 0.375,0.25 10 false A14 5.198,2.198 5.573,2.448 0.375,0.25 10 false A14 5.208,1.042 5.583,1.292 0.375,0.25 10 false A14 5.25,0.833 5.604,1.167 0.354,0.333 10 false 10 5.302,3.802 5.656,4.135 0.354,0.333 10 false 4 5.292,3.25 5.646,3.583 0.354,0.333 10 false 9 5.25,1.979 5.604,2.313 0.354,0.333 10 false 15 5.573,0.938 6.104,1.313 0.531,0.375 10 false NOPM 5.583,2.073 6.115,2.448 0.531,0.375 10 false OPM1 5.573,3.375 6.104,3.75 0.531,0.375 10 false OPM2 5.604,4.021 6.135,4.396 0.531,0.375 10 false E1 5.75,4.458 6.875,4.719 1.125,0.26 10 false EV Control ECU 0.083,2.844 1.615,3.083 1.531,0.24 10 false From Auxiliary Battery

PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (OIL PUMP WITH MOTOR ASSEMBLY)
a.
A480833

Check the connector connections and contact pressure of the relevant terminals for the oil pump with motor assembly connector.

HINT:

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE


OK:

The connector is connected securely and there are no contact problems.



Result:
Proceed to
OK
NG



OK

2.CHECK CONNECTOR CONNECTION CONDITION (EV CONTROL ECU CONNECTOR)

NG

CONNECT SECURELY

2.CHECK CONNECTOR CONNECTION CONDITION (EV CONTROL ECU CONNECTOR)

OK

3.CHECK FUSE (OIL PMP)

NG

CONNECT SECURELY

3.CHECK FUSE (OIL PMP)

Pre-procedure1

a.

Remove the OIL PMP fuse from the luggage room relay block.


Procedure1

a.
A481441C02
1.229,2.938 1.615,2.323 true 0.115,0.104 0.427,0.302 0.313,0.198 10 false *1 1.083,2.958 1.365,3.146 0.281,0.188 10 false *2
*1 Luggage Room Relay Block
*2 OIL PMP Fuse


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
OIL PMP fuse Always Below 1 Ω


Result:
Proceed to
OK
NG



Post-procedure1

a.

Install the OIL PMP fuse to the luggage room relay block.



OK

4.INSPECT OIL PMP MTR RELAY

NG

REPLACE FUSE (OIL PMP)

4.INSPECT OIL PMP MTR RELAY

Pre-procedure1

a.
A481442C01
2.51,2.844 2.313,2.229 true 0.115,0.083 0.427,0.281 0.313,0.198 10 false *1 2.49,2.896 2.802,3.094 0.313,0.198 10 false *2
*1 Luggage Room Relay Block
*2 OIL PMP MTR Relay


Remove the OIL PMP fuse from the luggage room relay block.


Procedure1

a.
A188757E18
1.906,0.302 2.094,0.302 2.094,0.302 2.146,0.563 false 3.031,0.302 2.813,0.302 2.813,0.302 2.708,0.563 false 2.646,1.115 3.104,1.115 false 2.646,1.604 3.104,1.604 false 0.365,0.771 0.521,0.969 0.156,0.198 10 3 1.813,0.24 1.969,0.406 0.156,0.167 10 1 1.302,1.292 1.458,1.49 0.156,0.198 10 2 0.354,1.302 0.51,1.469 0.156,0.167 10 1 3.094,0.24 3.25,0.438 0.156,0.198 10 2 1.302,0.76 1.458,0.958 0.156,0.198 10 5 3.177,1.031 3.333,1.229 0.156,0.198 10 5 3.177,1.521 3.333,1.719 0.156,0.198 10 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω


Result:
Proceed to
OK
NG



Post-procedure1

a.

Install the OIL PMP MTR relay.



OK

5.CHECK HARNESS AND CONNECTOR (LUGGAGE ROOM RELAY BLOCK)

NG

REPLACE OIL PMP MTR RELAY

5.CHECK HARNESS AND CONNECTOR (LUGGAGE ROOM RELAY BLOCK)

Pre-procedure1

a.

Remove the OIL PMP fuse from the luggage room relay block.


b.

Remove the OIL PMP MTR relay from the luggage room relay block.


Procedure1

a.
A481443C02
0.177,0.146 0.49,0.344 0.313,0.198 10 false *1 0.75,2.656 1.063,2.854 0.313,0.198 10 false *2 1.74,2.615 2.052,2.813 0.313,0.198 10 false *3
*1 Luggage Room Relay Block
*2 OIL PMP Fuse
*3 OIL PMP MTR Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (OIL PMP fuse) - 3 (OIL PMP MTR relay holder) Ignition switch off Below 1 Ω
2 (OIL PMP fuse) or 3 (OIL PMP MTR relay holder) - Body ground and other terminals Ignition switch off 10 kΩ or higher


NOTICE:

Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.


Result:
Proceed to
OK
NG



Post-procedure1

a.

Install the OIL PMP MTR relay.


b.

Install the OIL PMP fuse.



OK

6.CHECK HARNESS AND CONNECTOR (OIL PMP MTR RELAY - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (OIL PMP MTR RELAY - BODY GROUND)

Pre-procedure1

a.

Remove the OIL PMP MTR relay from the luggage room relay block.


Procedure1

a.
A481448C02
0.104,0.094 0.417,0.25 0.313,0.156 10 false *1 1.75,2.74 2.063,2.896 0.313,0.156 10 false *2
*1 Luggage Room Relay Block
*2 OIL PMP MTR Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (OIL PMP MTR relay holder) - Body ground Ignition switch off Below 1 Ω


NOTICE:

Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.


Result:
Proceed to
OK
NG



Post-procedure1

a.

Install the OIL PMP MTR relay.



OK

7.CHECK HARNESS AND CONNECTOR (OIL PUMP WITH MOTOR ASSEMBLY - OIL PMP MTR RELAY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (OIL PUMP WITH MOTOR ASSEMBLY - OIL PMP MTR RELAY)

Pre-procedure1

a.
A480833

Disconnect the G155 oil pump with motor assembly connector.


b.

Remove the OIL PMP MTR relay from the luggage room relay block.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

A481444C01
1.563,0.646 2.052,1.031 0.49,0.385 2.042,1.417 2.229,1.875 true 3.594,0.188 3.906,0.344 0.313,0.156 10 false *1 5.385,2.104 5.698,2.26 0.313,0.156 10 false *2 0.344,0.188 0.656,0.344 0.313,0.156 10 false *a 1.656,0.781 2.115,0.979 0.458,0.198 10 false G155 2.208,1.958 2.365,2.156 0.156,0.198 10 false L
*1 Luggage Room Relay Block *2 OIL PMP MTR Relay
*a Front view of wire harness connector
(to Oil Pump with Motor Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G155)Location & Routing

Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assembly

G155-4 (L) - 5 (OIL PMP MTR relay holder) Ignition switch off Below 1 Ω
G155-4 (L) or 5 (OIL PMP MTR relay holder) - Body ground and other terminals Ignition switch off 10 kΩ or higher


NOTICE:

Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.


Result:
Proceed to
OK
NG



Post-procedure1

a.

Install the OIL PMP MTR relay.


b.

Reconnect the G155 oil pump with motor assembly connector.



OK

8.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - OIL PMP MTR RELAY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - OIL PMP MTR RELAY)

Pre-procedure1

a.

Disconnect the G14*1 or A14*2 EV control ECU connector.

*1: for LHD

*2: for RHD


b.

Remove the OIL PMP MTR relay from the luggage room relay block.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

A481446C05
0.51,0.115 0.948,0.438 0.438,0.323 0.51,0.5 0.948,0.823 0.438,0.323 1.125,2.417 0.906,2.01 true 1.125,2.438 1.74,2.635 0.615,0.198 10 false OPM2 3.729,0.115 4.042,0.271 0.313,0.156 10 false *1 5.479,2.094 5.792,2.25 0.313,0.156 10 false *2 0.188,0.188 0.5,0.344 0.313,0.156 10 false *a 0.604,0.198 1.063,0.396 0.458,0.198 10 false G14 0.615,0.594 1.073,0.792 0.458,0.198 10 false A14 1,0.604 1.458,0.802 0.458,0.198 10 false *B 1,0.208 1.458,0.406 0.458,0.198 10 false *A
*A for LHD *B for RHD
*1 Luggage Room Relay Block *2 OIL PMP MTR Relay
*a Rear view of wire harness connector
(to EV Control ECU)
- -


Standard Resistance (Check for Open):
for LHD:
Tester Connection Condition Specified Condition

Click Location & Routing(G14)Location & Routing

Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECU

G14-9 (OPM2) - 1 (OIL PMP MTR relay holder) Ignition switch off Below 1 Ω
G14-9 (OPM2) or 1 (OIL PMP MTR relay holder) - Body ground and other terminals Ignition switch off 10 kΩ or higher

for RHD:
Tester Connection Condition Specified Condition

Click Location & Routing(A14)Location & Routing

Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECU

A14-9 (OPM2) - 1 (OIL PMP MTR relay holder) Ignition switch off Below 1 Ω
A14-9 (OPM2) or 1 (OIL PMP MTR relay holder) - Body ground and other terminals Ignition switch off 10 kΩ or higher


NOTICE:

Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.


Result:
Proceed to
OK
NG



Post-procedure1

a.

Install the OIL PMP MTR relay.


b.

Reconnect the G14*1 or A14*2 EV control ECU connector.

*1: for LHD

*2: for RHD



OK

9.CHECK HARNESS AND CONNECTOR (OIL PUMP WITH MOTOR ASSEMBLY - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.CHECK HARNESS AND CONNECTOR (OIL PUMP WITH MOTOR ASSEMBLY - BODY GROUND)

Pre-procedure1

a.
A480833

Disconnect the G155 oil pump with motor assembly connector.


Procedure1

a.
A459452C07
1.479,0.313 1.938,0.688 0.458,0.375 1.198,1.667 1.406,1.167 true 0.219,0.104 0.51,0.344 0.292,0.24 10 false *a 1.552,0.438 1.969,0.719 0.417,0.281 10 false G155 1.083,1.719 1.427,1.958 0.344,0.24 10 false OPG
*a Front view of wire harness connector
(to Oil Pump with Motor Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G155)Location & Routing

Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assembly

G155-1 (OPG) - Body ground Ignition switch off Below 1 Ω


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the G155 oil pump with motor assembly connector.



OK

10.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - OIL PUMP WITH MOTOR ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - OIL PUMP WITH MOTOR ASSEMBLY)

Pre-procedure1

a.

Disconnect the G14*1 or A14*2 EV control ECU connector.

*1: for LHD

*2: for RHD


b.
A480833

Disconnect the G155 oil pump with motor assembly connector.


Procedure1

a.
A481447C06
0.885,1.729 1.323,2.083 0.438,0.354 1.438,2.792 1.917,3.146 0.479,0.354 0.885,2.167 1.323,2.521 0.438,0.354 0.792,2.604 0.573,2.052 true 1.979,4.135 1.615,3.552 true 0.094,0.104 0.406,0.26 0.313,0.156 10 false *a 0.177,2.844 0.49,3 0.313,0.156 10 false *b 0.979,1.823 1.438,2.021 0.458,0.198 10 false G14 1.521,2.906 1.979,3.104 0.458,0.198 10 false G155 0.635,2.625 1.25,2.823 0.615,0.198 10 false NOPM 2.021,4.198 2.635,4.396 0.615,0.198 10 false NOPM 0.99,2.26 1.448,2.458 0.458,0.198 10 false A14 1.385,1.844 1.844,2.042 0.458,0.198 10 false *A 1.385,2.25 1.844,2.448 0.458,0.198 10 false *B
*A for LHD
*B for RHD
*a Rear view of wire harness connector
(to EV Control ECU)
*b Front view of wire harness connector
(to Oil Pump with Motor Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for LHD:
Tester Connection Condition Specified Condition

Click Location & Routing(G14,G155)Location & Routing

Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECU

Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assembly

G14-10 (NOPM) - G155-2 (NOPM) Ignition switch off Below 1 Ω
G14-10 (NOPM) or G155-2 (NOPM) - Body ground and other terminals Ignition switch off 10 kΩ or higher

for RHD:
Tester Connection Condition Specified Condition

Click Location & Routing(A14,G155)Location & Routing

Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECU

Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assembly

A14-10 (NOPM) - G155-2 (NOPM) Ignition switch off Below 1 Ω
A14-10 (NOPM) or G155-2 (NOPM) - Body ground and other terminals Ignition switch off 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the G155 oil pump with motor assembly connector.


b.

Reconnect the G14*1 or A14*2 EV control ECU connector.

*1: for LHD

*2: for RHD



OK

11.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - OIL PUMP WITH MOTOR ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

11.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - OIL PUMP WITH MOTOR ASSEMBLY)

Pre-procedure1

a.

Disconnect the G14*1 or A14*2 EV control ECU connector.

*1: for LHD

*2: for RHD


b.
A480833

Disconnect the G155 oil pump with motor assembly connector.


Procedure1

a.
A481447C07
1.427,2.813 1.927,3.156 0.5,0.344 0.854,1.729 1.302,2.073 0.448,0.344 0.854,2.167 1.302,2.51 0.448,0.344 0.677,2.719 0.344,2.052 true 2.167,4.146 1.802,3.563 true 0.094,0.104 0.406,0.26 0.313,0.156 10 false *a 0.115,2.802 0.427,2.958 0.313,0.156 10 false *b 0.948,1.823 1.406,2.021 0.458,0.198 10 false G14 1.521,2.917 1.979,3.115 0.458,0.198 10 false G155 0.552,2.74 1.167,2.938 0.615,0.198 10 false OPM1 2.208,4.167 2.823,4.365 0.615,0.198 10 false OPM1 0.958,2.26 1.417,2.458 0.458,0.198 10 false A14 1.365,2.302 1.823,2.5 0.458,0.198 10 false *B 1.375,1.844 1.833,2.042 0.458,0.198 10 false *A
*A for LHD
*B for RHD
*a Rear view of wire harness connector
(to EV Control ECU)
*b Front view of wire harness connector
(to Oil Pump with Motor Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for LHD:
Tester Connection Condition Specified Condition

Click Location & Routing(G14,G155)Location & Routing

Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECU

Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assembly

G14-15 (OPM1) - G155-3 (OPM1) Ignition switch off Below 1 Ω
G14-15 (OPM1) or G155-3 (OPM1) - Body ground and other terminals Ignition switch off 10 kΩ or higher

for RHD:
Tester Connection Condition Specified Condition

Click Location & Routing(A14,G155)Location & Routing

Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECU

Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assembly

A14-15 (OPM1) - G155-3 (OPM1) Ignition switch off Below 1 Ω
A14-15 (OPM1) or G155-3 (OPM1) - Body ground and other terminals Ignition switch off 10 kΩ or higher



b.

Connect the cable to the negative (-) auxiliary battery terminal.


c.

Turn the ignition switch to ON.


d.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
for LHD:
Tester Connection Condition Specified Condition

Click Location & Routing(G14,G155)Location & Routing

Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECU

Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assembly

G14-15 (OPM1) or G155-3 (OPM1) - Body ground Ignition switch off Below 1 V

for RHD:
Tester Connection Condition Specified Condition

Click Location & Routing(A14,G155)Location & Routing

Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECU

Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assembly

A14-15 (OPM1) or G155-3 (OPM1) - Body ground Ignition switch off Below 1 V


NOTICE:

Turning the ignition switch to ON with the EV control ECU and oil pump with motor assembly connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.


b.

Disconnect the cable from the negative (-) auxiliary battery terminal.


c.

Reconnect the G155 oil pump with motor assembly connector.


d.

Reconnect the G14*1 or A14*2 EV control ECU connector.

*1: for LHD

*2: for RHD



OK

12.PERFORM ACTIVE TEST USING GTS (CONTROL THE MOTOR/GENERATOR COOLING OIL PUMP MOTOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

12.PERFORM ACTIVE TEST USING GTS (CONTROL THE MOTOR/GENERATOR COOLING OIL PUMP MOTOR)

Pre-procedure1

a.

Set the Duty ratio to 90%.

HINT:

The active test is not performed when the Duty ratio is 50% or lower or 95% or higher, or the ambient temperature is -11°C (12.2°F) or lower.


Powertrain > EV > Active Test
Active Test Display
Control the Motor/Generator Cooling Oil Pump
Data List Display
MG Cooling Oil Pump Motor Speed
50004 397 42002 803

Procedure1

a.

Check the oil pump with motor is speed.

OK:

450 to 7000 rpm


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.



OK

NG