The EV control ECU detects drive motor temperature based on signals from the drive motor temperature sensor and activates the OIL PMP MTR relay and oil pump with motor assembly.
The EV control ECU monitors NOPM signals from the oil pump driver and detects malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P260031 | Motor/Generator Coolant Pump "A" Control Circuit No Signal | When the OIL PMP MTR relay is on, the NOPM pulse signal is not output.
(2 trip detection logic) |
·
FCV with motor transaxle assembly ·
Oil pump with motor assembly ·
OIL PMP MTR relay ·
OIL PMP fuse ·
EV control ECU ·
Wire harness or connector |
Master Warning:
Comes on |
EV | A |
| DTC No. | Data List |
|---|---|
| P260031 | ·
Target Motor/Generator Cooling Oil Pump Motor Duty ·
Motor/Generator Cooling Oil Pump Motor Revolution ·
Motor/Generator Cooling Oil Pump Motor Power Relay Request |
The oil pump with motor assembly cannot be activated only with the OIL PMP MTR relay on. It is activated after receiving the command signals (OPM1) from the EV control ECU.
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Enter the following menus: Powertrain / EV / Active Test / Control the Motor/Generator Cooling Oil Pump.
According to the display on the GTS, perform the Active Test and set the duty to 90%.
The Active Test cannot be performed if the duty ratio is set to 50% or lower or 95% or higher, or if the ambient temperature is -11°C (12.2°F) or lower.
According to the display on the GTS, read the Data List and check that the value of "Motor/Generator Cooling Oil Pump Motor Revolution" is between 450 rpm and 7000 rpm.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Check the connector connections and contact pressure of the relevant terminals for the oil pump with motor assembly connector.
The connector is connected securely and there are no contact problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Remove the OIL PMP fuse from the luggage room relay block.
Procedure1
| *1 | Luggage Room Relay Block |
| *2 | OIL PMP Fuse |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| OIL PMP fuse | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the OIL PMP fuse to the luggage room relay block.
OK
NG
Pre-procedure1
| *1 | Luggage Room Relay Block |
| *2 | OIL PMP MTR Relay |
Remove the OIL PMP fuse from the luggage room relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the OIL PMP MTR relay.
OK
NG
Pre-procedure1
Remove the OIL PMP fuse from the luggage room relay block.
Remove the OIL PMP MTR relay from the luggage room relay block.
Procedure1
| *1 | Luggage Room Relay Block |
| *2 | OIL PMP Fuse |
| *3 | OIL PMP MTR Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (OIL PMP fuse) - 3 (OIL PMP MTR relay holder) | Ignition switch off | Below 1 Ω |
| 2 (OIL PMP fuse) or 3 (OIL PMP MTR relay holder) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the OIL PMP MTR relay.
Install the OIL PMP fuse.
OK
NG
Pre-procedure1
Remove the OIL PMP MTR relay from the luggage room relay block.
Procedure1
| *1 | Luggage Room Relay Block |
| *2 | OIL PMP MTR Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (OIL PMP MTR relay holder) - Body ground | Ignition switch off | Below 1 Ω |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the OIL PMP MTR relay.
OK
NG
Pre-procedure1
Disconnect the G155 oil pump with motor assembly connector.
Remove the OIL PMP MTR relay from the luggage room relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | Luggage Room Relay Block | *2 | OIL PMP MTR Relay |
| *a | Front view of wire harness connector
(to Oil Pump with Motor Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G155)Location & Routingewd_type=routing;type=c;code=G155 Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assemblyewd_type=component;type=c;code=G155;pinno=4 |
||
| G155-4 (L) - 5 (OIL PMP MTR relay holder) | Ignition switch off | Below 1 Ω |
| G155-4 (L) or 5 (OIL PMP MTR relay holder) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the OIL PMP MTR relay.
Reconnect the G155 oil pump with motor assembly connector.
OK
NG
Pre-procedure1
Disconnect the G14*1 or A14*2 EV control ECU connector.
*1: for LHD
*2: for RHD
Remove the OIL PMP MTR relay from the luggage room relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *1 | Luggage Room Relay Block | *2 | OIL PMP MTR Relay |
| *a | Rear view of wire harness connector
(to EV Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G14)Location & Routingewd_type=routing;type=c;code=G14 Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECUewd_type=component;type=c;code=G14;pinno=9 |
||
| G14-9 (OPM2) - 1 (OIL PMP MTR relay holder) | Ignition switch off | Below 1 Ω |
| G14-9 (OPM2) or 1 (OIL PMP MTR relay holder) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A14)Location & Routingewd_type=routing;type=c;code=A14 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=9 |
||
| A14-9 (OPM2) - 1 (OIL PMP MTR relay holder) | Ignition switch off | Below 1 Ω |
| A14-9 (OPM2) or 1 (OIL PMP MTR relay holder) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the OIL PMP MTR relay.
Reconnect the G14*1 or A14*2 EV control ECU connector.
*1: for LHD
*2: for RHD
OK
NG
Pre-procedure1
Disconnect the G155 oil pump with motor assembly connector.
Procedure1
| *a | Front view of wire harness connector
(to Oil Pump with Motor Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G155)Location & Routingewd_type=routing;type=c;code=G155 Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assemblyewd_type=component;type=c;code=G155;pinno=1 |
||
| G155-1 (OPG) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the G155 oil pump with motor assembly connector.
OK
NG
Pre-procedure1
Disconnect the G14*1 or A14*2 EV control ECU connector.
*1: for LHD
*2: for RHD
Disconnect the G155 oil pump with motor assembly connector.
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Rear view of wire harness connector
(to EV Control ECU) |
| *b | Front view of wire harness connector
(to Oil Pump with Motor Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G14,G155)Location & Routingewd_type=routing;type=c,c;code=G14,G155 Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECUewd_type=component;type=c;code=G14;pinno=10 Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assemblyewd_type=component;type=c;code=G155;pinno=2 |
||
| G14-10 (NOPM) - G155-2 (NOPM) | Ignition switch off | Below 1 Ω |
| G14-10 (NOPM) or G155-2 (NOPM) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A14,G155)Location & Routingewd_type=routing;type=c,c;code=A14,G155 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=10 Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assemblyewd_type=component;type=c;code=G155;pinno=2 |
||
| A14-10 (NOPM) - G155-2 (NOPM) | Ignition switch off | Below 1 Ω |
| A14-10 (NOPM) or G155-2 (NOPM) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the G155 oil pump with motor assembly connector.
Reconnect the G14*1 or A14*2 EV control ECU connector.
*1: for LHD
*2: for RHD
OK
NG
Pre-procedure1
Disconnect the G14*1 or A14*2 EV control ECU connector.
*1: for LHD
*2: for RHD
Disconnect the G155 oil pump with motor assembly connector.
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Rear view of wire harness connector
(to EV Control ECU) |
| *b | Front view of wire harness connector
(to Oil Pump with Motor Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G14,G155)Location & Routingewd_type=routing;type=c,c;code=G14,G155 Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECUewd_type=component;type=c;code=G14;pinno=15 Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assemblyewd_type=component;type=c;code=G155;pinno=3 |
||
| G14-15 (OPM1) - G155-3 (OPM1) | Ignition switch off | Below 1 Ω |
| G14-15 (OPM1) or G155-3 (OPM1) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A14,G155)Location & Routingewd_type=routing;type=c,c;code=A14,G155 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=15 Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assemblyewd_type=component;type=c;code=G155;pinno=3 |
||
| A14-15 (OPM1) - G155-3 (OPM1) | Ignition switch off | Below 1 Ω |
| A14-15 (OPM1) or G155-3 (OPM1) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G14,G155)Location & Routingewd_type=routing;type=c,c;code=G14,G155 Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECUewd_type=component;type=c;code=G14;pinno=15 Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assemblyewd_type=component;type=c;code=G155;pinno=3 |
||
| G14-15 (OPM1) or G155-3 (OPM1) - Body ground | Ignition switch off | Below 1 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A14,G155)Location & Routingewd_type=routing;type=c,c;code=A14,G155 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=15 Click Connector(G155)Body>Floor Wire / No. 3 Floor Wire>Oil Pump with Motor Assemblyewd_type=component;type=c;code=G155;pinno=3 |
||
| A14-15 (OPM1) or G155-3 (OPM1) - Body ground | Ignition switch off | Below 1 V |
Turning the ignition switch to ON with the EV control ECU and oil pump with motor assembly connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the G155 oil pump with motor assembly connector.
Reconnect the G14*1 or A14*2 EV control ECU connector.
*1: for LHD
*2: for RHD
OK
NG
Pre-procedure1
Set the Duty ratio to 90%.
The active test is not performed when the Duty ratio is 50% or lower or 95% or higher, or the ambient temperature is -11°C (12.2°F) or lower.
| Active Test Display |
|---|
| Control the Motor/Generator Cooling Oil Pump |
| Data List Display |
|---|
| MG Cooling Oil Pump Motor Speed |
Procedure1
Check the oil pump with motor is speed.
450 to 7000 rpm
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
OK
NG