The cause of the malfunction may be the high-voltage circuit of the motor.
Check the motor internal resistance and the connection condition of the high-voltage line between the inverter and motor to check whether there is an open or short circuit.
| Area | Inspection |
|---|---|
| Motor cable connection check | Check for open or short circuit in the connection condition of the cable from the inverter to the motor. |
| Motor, motor cable and No. 2 battery pack wire | Check the motor (including cable) internal resistance and insulation resistance with body ground to check for an open or short circuit. |
This step is referenced from the procedures for each DTC.
If the inspection results below are normal, perform the next procedure for the referenced DTC.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the electric vehicle charger assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Procedure1
| *A | for LHD |
| *B | for RHD |
Check that the bolts for the No. 2 battery pack wire are tightened to the specified torque, the No. 2 battery pack wire is connected securely, and there are no contact problems.
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Disconnect the No. 2 battery pack wire from the inverter with converter assembly.
Check for arc marks at the terminals for the No. 2 battery pack wire.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Connect the No. 2 battery pack wire to the inverter with converter assembly.
Install the inverter terminal cover.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Disconnect the No. 2 battery pack wire from the inverter with converter assembly.
Procedure1
| *A | for LHD |
| *B | for RHD |
| *1 | Shield Ground |
| *a | No. 2 Battery Pack Wire
(Inverter with Converter Assembly Side) |
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
If the motor (MG2) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O2)Location & Routingewd_type=routing;type=c;code=O2 Click Connector(O2)Engine Compartment>EV Battery Pack Wire>Inverter with Converter Assemblyewd_type=component;type=c;code=O2;pinno=1,3,2 |
||
| O2-1 (R-W) - O2-3 (R-U) | Ignition switch off | 70.2 to 78.1 mΩ |
| O2-3 (R-U) - O2-2(R-V) | Ignition switch off | 70.3 to 78.2 mΩ |
| O2-2(R-V) - O2-1 (R-W) | Ignition switch off | 70.0 to 77.9 mΩ |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O1)Location & Routingewd_type=routing;type=c;code=O1 Click Connector(O1)Engine Compartment>EV Battery Pack Wire>Inverter with Converter Assemblyewd_type=component;type=c;code=O1;pinno=3,1,2 |
||
| O1-3 (R-W) - O1-1 (R-U) | Ignition switch off | 70.2 to 78.1 mΩ |
| O1-1 (R-U) - O1-2 (R-V) | Ignition switch off | 70.3 to 78.2 mΩ |
| O1-2(R-V) - O1-3 (R-W) | Ignition switch off | 70.0 to 77.9 mΩ |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C (°F).)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O2)Location & Routingewd_type=routing;type=c;code=O2 Click Connector(O2)Engine Compartment>EV Battery Pack Wire>Inverter with Converter Assemblyewd_type=component;type=c;code=O2;pinno=1,3,2 |
||
| O2-1 (R-W) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| O2-3 (R-U) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| O2-2 (R-V) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O1)Location & Routingewd_type=routing;type=c;code=O1 Click Connector(O1)Engine Compartment>EV Battery Pack Wire>Inverter with Converter Assemblyewd_type=component;type=c;code=O1;pinno=3,1,2 |
||
| O1-3 (R-W) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| O1-1 (R-U) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| O1-2 (R-V) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the No. 2 battery pack wire.
Install the inverter terminal cover.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the connector cover.
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
Disconnect the motor cable from the FCV with motor transaxle assembly.
Procedure1
Check for arc marks at the terminals for the motor cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Connect the motor cable to the FCV with motor transaxle assembly.
Install the connector cover.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 battery pack wire.
Procedure1
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| *A | for LHD | *B | for RHD |
| *1 | Shield Ground | - | - |
| *a | NO. 2 Battery Pack Wire | - | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O2,O3)Location & Routingewd_type=routing;type=c,c;code=O2,O3 Click Connector(O2)Engine Compartment>EV Battery Pack Wire>Inverter with Converter Assemblyewd_type=component;type=c;code=O2;pinno=1,2,3 Click Connector(O3)Body>EV Battery Pack Wire>Shortcut Connectorewd_type=component;type=c;code=O3;pinno=1,2,3 |
||
| O2-1 (R-U) or O3-1 (R-U) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| O2-2 (R-V) or O3-2 (R-V) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| O2-3 (R-W) or O3-3 (R-W) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O1,O3)Location & Routingewd_type=routing;type=c,c;code=O1,O3 Click Connector(O1)Engine Compartment>EV Battery Pack Wire>Inverter with Converter Assemblyewd_type=component;type=c;code=O1;pinno=1,2,3 Click Connector(O3)Body>EV Battery Pack Wire>Shortcut Connectorewd_type=component;type=c;code=O3;pinno=1,2,3 |
||
| O1-1 (R-U) or O3-1 (R-U) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| O1-2 (R-V) or O3-2 (R-V) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
| O1-3 (R-W) or O3-3 (R-W) - Body ground and shield ground | Ignition switch off | 10 MΩ or higher |
Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O2,O3)Location & Routingewd_type=routing;type=c,c;code=O2,O3 Click Connector(O2)Engine Compartment>EV Battery Pack Wire>Inverter with Converter Assemblyewd_type=component;type=c;code=O2;pinno=1,2,3 Click Connector(O3)Body>EV Battery Pack Wire>Shortcut Connectorewd_type=component;type=c;code=O3;pinno=1,2,3 |
||
| O2-1 (R-U) - O3-1 (R-U) | Ignition switch off | Below 1 Ω |
| O2-2 (R-V) - O3-2 (R-V) | Ignition switch off | Below 1 Ω |
| O2-3 (R-W) - O3-3 (R-W) | Ignition switch off | Below 1 Ω |
| O2-1 (R-U) - O3-2 (R-V) | Ignition switch off | 10 MΩ or higher |
| O2-2 (R-V) - O3-3 (R-W) | Ignition switch off | 10 MΩ or higher |
| O2-3 (R-W) - O3-1 (R-U) | Ignition switch off | 10 MΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O1,O3)Location & Routingewd_type=routing;type=c,c;code=O1,O3 Click Connector(O1)Engine Compartment>EV Battery Pack Wire>Inverter with Converter Assemblyewd_type=component;type=c;code=O1;pinno=1,2,3 Click Connector(O3)Body>EV Battery Pack Wire>Shortcut Connectorewd_type=component;type=c;code=O3;pinno=1,2,3 |
||
| O1-1 (R-U) - O3-1 (R-U) | Ignition switch off | Below 1 Ω |
| O1-2 (R-V) - O3-2 (R-V) | Ignition switch off | Below 1 Ω |
| O1-3 (R-W) - O3-3 (R-W) | Ignition switch off | Below 1 Ω |
| O1-1 (R-U) - O3-2 (R-V) | Ignition switch off | 10 MΩ or higher |
| O1-2 (R-V) - O3-3 (R-W) | Ignition switch off | 10 MΩ or higher |
| O1-3 (R-W) - O3-1 (R-U) | Ignition switch off | 10 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the No. 2 battery pack wire.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the motor cable.
Procedure1
| *1 | Shield Ground |
| *a | Motor Cable |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(q1,q2)Location & Routingewd_type=routing;type=c,c;code=q1,q2 Click Connector(q1)Body>Motor Cable>FCV Transaxle with Motor Assemblyewd_type=component;type=c;code=q1;pinno=1,2,3 Click Connector(q2)Body>Motor Cable>Shortcut Connectorewd_type=component;type=c;code=q2;pinno=3,2,1 |
||
| q1-1 (W) or q2-3 (W) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| q1-2 (V) or q2-2 (V) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| q1-3 (U) or q2-1 (U) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(q1,q2)Location & Routingewd_type=routing;type=c,c;code=q1,q2 Click Connector(q1)Body>Motor Cable>FCV Transaxle with Motor Assemblyewd_type=component;type=c;code=q1;pinno=1,2,3 Click Connector(q2)Body>Motor Cable>Shortcut Connectorewd_type=component;type=c;code=q2;pinno=3,2,1 |
||
| q1-1 (W) - q2-3 (W) | Ignition switch off | Below 1 Ω |
| q1-2 (V) - q2-2 (V) | Ignition switch off | Below 1 Ω |
| q1-3 (U) - q2-1 (U) | Ignition switch off | Below 1 Ω |
| q1-1 (W) - q2-2 (V) | Ignition switch off | 10 MΩ or higher |
| q1-2 (V) - q2-1 (U) | Ignition switch off | 10 MΩ or higher |
| q1-3 (U) - q2-3 (W) | Ignition switch off | 10 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the motor cable.
OK
NG