Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
| *a | When inside of piping is pressurized |
Do not install or remove any hydrogen system components without first performing depressurization procedures.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
| *a | Manual Valve Open |
Do not perform depressurization procedures when the manual valve of the hydrogen tank assembly is open.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
When performing depressurization, do not perform procedures by hand without wearing protective glasses and gloves.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
| *a | After depressurization procedures, the high pressure piping union nut that is loosened first. |
After performing depressurization procedures, when first loosening the union nut of the high pressure hydrogen piping, do not loosen the union nut by hand without wearing protective glasses and gloves.
Even when depressurization procedures are performed, the pressurized hydrogen gas inside the high pressure hydrogen piping cannot be completely depressurized, so the highly pressurized hydrogen gas remaining in the high pressure hydrogen piping could blow out, resulting in a serious accident.
When opening the tank shut valve and applying pressure to SST (hydrogen venting tool), stay away from SST (flexible hose).
If SST (flexible hose) comes off, you could be struck by the loose end of SST (flexible hose), causing a serious accident.
1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
Place signs [HIGH PRESSURE GAS WORK IN PROGRESS - DO NOT TOUCH!], etc. to warn other technicians to be cautious. (An example sign is included, so make a copy and use it.)
When performing depressurization, do not open or close any parts of the hydrogen gas piping except for the following:
- Adjustment bolt of the hydrogen tank assembly manual valve
- Tank shut valve of the hydrogen tank assembly
- No. 1 hydrogen supply regulator plug
When installing or removing the hydrogen tank assembly, high pressure hydrogen piping, hydrogen inlet receptacle, hydrogen tank tube joint assembly or hydrogen supply regulator, to prevent strain such as twisting from being applied to the high pressure hydrogen piping.
Even when not removing or installing the high pressure hydrogen piping, be careful not to pull or otherwise apply strain to the high pressure hydrogen piping.
When reusable parts such as the hydrogen tank assembly valve portion, hydrogen inlet receptacle, hydrogen tank tube joint assembly and hydrogen supply regulator have been removed, to protect the seal portions and threaded portions from damage as well as to prevent foreign matter such as dust and metal fragments from entering through openings, cover these areas with protective tape.
Do not use packing tape, or any other tape that will leave residue on parts, as protective tape.
| *a | Protective Tape |
| *b | Seal Portion |
| *c | Threaded Portion |
Protect seal portions and threaded portions as shown in the illustration.
To protect the seal portions and threaded portions from damage or contamination by foreign matter, remove the protective tape immediately before installation.
When reassembling components that have been removed, make sure that there is no foreign matter adhering to the openings.
After installing high pressure hydrogen system components, first perform primary leak inspection with low pressure nitrogen gas, and then perform secondary leak inspection.
| *a | Atmosphere Ventilation Hole Cap |
| *b | Relief Valve |
Do not insert any sharp objects into the relief valve of the hydrogen supply regulator.
Do not remove the atmosphere ventilation hole cap of the hydrogen supply regulator.
When the vehicle is parked with the ignition switch off, if the FC control ECU judges that the FC stack temperature will go below 0°C (32°F), it activates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds and drains water from the FC stack assembly. When performing inspection or repairs with the ignition switch off (not on (IG) or on (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
58404B
2.REMOVE REAR NO. 4 FLOOR BOARD SUB-ASSEMBLY
58403L
3.REMOVE REAR NO. 3 FLOOR BOARD SUB-ASSEMBLY
58402K
4.REMOVE NO. 2 FLOOR BOARD SUB-ASSEMBLY
57628E
5.REMOVE REAR FLOOR SIDE MEMBER COVER LH
58398F
6.REMOVE NO. 1 FLOOR UNDER COVER
17DB3
7.REMOVE NO. 3 FC EXHAUST PIPE
8. PRESSURE RELEASE OPERATION (for Low Pressure and Medium Pressure)
| *a | Manual Valve Open |
| *b | Manual Valve Closed |
| *c | Adjustment Bolt |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 1 hydrogen tank assembly.
The manual valve shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 1 hydrogen tank assembly must be replaced.
| *a | Manual Valve Open |
| *b | Manual Valve Closed |
| *c | Adjustment Bolt |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 2 hydrogen tank assembly.
The manual valve shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 2 hydrogen tank assembly must be replaced.
| *a | Manual Valve Open |
| *b | Manual Valve Closed |
| *c | Adjustment Bolt |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 3 hydrogen tank assembly.
The manual valve shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 3 hydrogen tank assembly must be replaced.
Before starting the depressurization procedure, first check that there is no mud or other contaminant around the medium pressure leak check port of the hydrogen supply regulator, and clean it as necessary.
Installing the No. 1 hydrogen supply regulator plug while any foreign matter adheres to it can cause a hydrogen gas leak.
Make sure that the manual valves of the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly are closed.
Slowly loosen the No. 1 hydrogen supply regulator plug until the hissing sound of gas escaping can be heard, then stop loosening the No. 1 hydrogen supply regulator plug and wait for the sound to stop. Repeat this procedure multiple times until the sound stops occurring, in order to depressurize the compressed hydrogen gas from the medium pressure leak check port of the hydrogen supply regulator.
| *a | Manual Valve Open |
Do not perform depressurization procedures when the manual valve of the hydrogen tank assembly is open.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
When performing depressurization, do not perform procedures by hand without wearing protective glasses and gloves.
High pressure nitrogen gas could cause a serious accident.
When performing depressurization, only loosen the No. 1 hydrogen supply regulator plug. Do not remove it.
Blow compressed air at the underside of the vehicle to disperse any accumulated hydrogen gas.
Remove the No. 1 hydrogen supply regulator plug from the hydrogen supply regulator.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
Remove the O-ring from the hydrogen supply regulator.
| *a | Protective Tape |
To prevent damage to the seal portions and threaded portions, and to prevent foreign matter such as dust or metal fragments from entering the openings, cover the seal portions, threaded portions, and openings of the hydrogen supply regulator with protective tape.
To prevent damage to the seal portions and threaded portions, and to prevent foreign matter such as dust or metal fragments from entering the openings, do not remove the protective tape covering the seal portions, threaded portions, and openings of the hydrogen supply regulator until immediately before performing work.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
Apply TOYOTA Genuine FC Grease to a new O-ring and to the threaded portion of the hydrogen supply regulator.
Install the O-ring to the hydrogen supply regulator.
During installation, make sure not to damage the O-ring.
| *a | Specified tightening torque |
Using SST install the No. 1 hydrogen supply regulator plug to the hydrogen supply regulator.
9.0 N*m (92 kgf*cm, 80 in.*lbf)
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 40 mm (1.57 in.)) + torque wrench (fulcrum length of 162 mm (6.38 in.)): 7.2 N*m (73 kgf*cm, 64 in.*lbf)
9. PRESSURE RELEASE OPERATION (for High Pressure)
Prepare SST (hydrogen venting tool).
Click hereEngine / Hybrid System>FUEL>FUEL SYSTEM>DISCHARGE COMPRESSED HYDROGEN GAS
| *a | SST (Venting Stand) |
Check that the open/close valve of SST (venting stand) is closed.
| *a | Manual Valve Open |
| *b | Manual Valve Closed |
| *c | Adjustment Bolt |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 1 hydrogen tank assembly.
The manual valve shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 1 hydrogen tank assembly must be replaced.
| *a | Manual Valve Open |
| *b | Manual Valve Closed |
| *c | Adjustment Bolt |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 2 hydrogen tank assembly.
The manual valve shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 2 hydrogen tank assembly must be replaced.
| *a | Manual Valve Open |
| *b | Manual Valve Closed |
| *c | Adjustment Bolt |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 3 hydrogen tank assembly.
The manual valve shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 3 hydrogen tank assembly must be replaced.
Before starting the depressurization procedure, first check that there is no mud or other contaminant around the medium pressure leak check port of the hydrogen supply regulator, and clean it as necessary.
Installing the No. 1 hydrogen supply regulator plug while any foreign matter adheres to it can cause a hydrogen gas leak.
Make sure that the manual valves of the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly are closed.
Slowly loosen the No. 1 hydrogen supply regulator plug until the hissing sound of gas escaping can be heard, then stop loosening the No. 1 hydrogen supply regulator plug and wait for the sound to stop. Repeat this procedure multiple times until the sound stops occurring, in order to depressurize the compressed hydrogen gas from the medium pressure leak check port of the hydrogen supply regulator.
| *a | Manual Valve Open |
Do not perform depressurization procedures when the manual valve of the hydrogen tank assembly is open.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
When performing depressurization, do not perform procedures by hand without wearing protective glasses and gloves.
High pressure nitrogen gas could cause a serious accident.
When performing depressurization, only loosen the No. 1 hydrogen supply regulator plug. Do not remove it.
Blow compressed air at the underside of the vehicle to disperse any accumulated hydrogen gas.
Remove the No. 1 hydrogen supply regulator plug from the hydrogen supply regulator.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
Remove the O-ring from the hydrogen supply regulator.
| *a | Protective Tape |
To prevent damage to the seal portions and threaded portions, and to prevent foreign matter such as dust or metal fragments from entering the openings, cover the seal portions, threaded portions, and openings of the hydrogen supply regulator with protective tape.
To prevent damage to the seal portions and threaded portions, and to prevent foreign matter such as dust or metal fragments from entering the openings, do not remove the protective tape covering the seal portions, threaded portions, and openings of the hydrogen supply regulator until immediately before performing work.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
Apply TOYOTA Genuine FC Grease to a new O-ring and to the threaded portion of the hydrogen supply regulator.
Install the O-ring to the hydrogen supply regulator.
During installation, make sure not to damage the O-ring.
Connect SST (hydrogen venting tool).
| *a | Concept of SST (hydrogen venting tool) Connection | *b | SST (Upper Release Pipe) |
| *c | SST (Middle Release Pipe) | *d | SST (Lower Release Pipe) |
| *e | SST (Venting Stand) | *f | SST (Flexible Hose) |
There are 2 types of SST (flexible hose).
| *a | Type A | *b | Type B |
for Type A:
| *a | SST (Flexible Hose) |
Temporarily install SST (flexible hose) to the hydrogen supply regulator.
| *a | SST (Open End Wrench) |
| *b | SST (Flexible Hose) |
| *c | Specified tightening torque |
Using SST(open end wrench), tighten SST (flexible hose).
9.0 N*m (92 kgf*cm, 80 in.*lbf)
Make sure that SST (flexible hose) does not interfere with part of the vehicle.
If SST (flexible hose) interferes with any part of the vehicle, protect it with a piece of cloth, etc.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 40 mm (1.57 in.)) + torque wrench (fulcrum length of 162 mm (6.38 in.)): 7.2 N*m (73 kgf*cm, 64 in.*lbf)
| *a | SST (Flexible Hose) |
| *b | SST (Venting Stand) |
Connect SST (flexible hose) to SST (Venting Stand).
for Type B:
Remove the 3 bolts of the hydrogen supply regulator.
| *a | SST (Flexible Hose) |
Temporarily install SST (flexible hose) to the hydrogen supply regulator.
Install the hydrogen supply regulator with the 3 bolts.
| *a | SST (Open End Wrench) |
| *b | SST (Flexible Hose) |
| *c | Specified tightening torque |
Using SST(open end wrench), tighten SST (flexible hose).
9.0 N*m (92 kgf*cm, 80 in.*lbf)
Make sure that SST (flexible hose) does not interfere with part of the vehicle.
If SST (flexible hose) interferes with any part of the vehicle, protect it with a piece of cloth, etc.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 40 mm (1.57 in.)) + torque wrench (fulcrum length of 162 mm (6.38 in.)): 7.2 N*m (73 kgf*cm, 64 in.*lbf)
| *a | SST (Flexible Hose) |
| *b | SST (Venting Stand) |
Connect SST (flexible hose) to SST (venting stand).
Under basic conditions:
Set SST (hydrogen venting tool) in an outdoor location.
Take care that the compressed hydrogen gas that is discharged during the discharging procedure does not enter any indoor location.
Other than basic conditions (when outdoor setup is not possible):
When SST (hydrogen venting tool) will be set up indoors, locate it along a wall near a window, and with the tip of SST (upper release pipe) outdoors.
Open windows on two sides or more, and ensure that there is adequate ventilation to prevent the compressed hydrogen gas that is discharged from collecting inside.
Open the tank shut valves of the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly No. 3 hydrogen tank assembly, and after 2 to 3 seconds, close the tank shut valves again.
When opening the tank shut valve and applying pressure to SST (hydrogen venting tool), stay away from SST (flexible hose).
If SST (flexible hose) comes off, you could be struck by the loose end of SST (flexible hose), causing a serious accident.
If the Data List item "Medium-range Hydrogen Pressure (gauge)" decreases to below 0.7 MPa (7.1 kgf/cm2, 102 psi) the tank shut valves of the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly will forcibly close.
If the tank shut valves of the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly do not open, open the tank shut valves again, and after 2 to 3 seconds, close the tank shut valves.
Perform preliminary leak check (using remaining piping pressure).
Perform leak check using the pressure remaining upstream of the tank shut valve.
If there are any water droplets, etc. adhering to the measurement locations, wipe them away before performing the procedure.
Performing the measurement while any water droplets, etc. are adhering could damage the hydrogen gas detector.
Using SST and a hydrogen gas detector, inspect for leaks in the locations shown in the illustration.
Less than 500 ppm
If any values are outside the specified range, disconnect those locations that have leaks and assemble the parts again.
| *a | Locations to Check for Leaks | - | - |
|
Leak Check Location | - | - |
Using the GTS, enter the following menus: Powertrain / FC / Data List / Medium-range Hydrogen Pressure
| Tester Display |
|---|
| Medium-Range Hydrogen Pressure |
If the GTS setting is absolute pressure (abs), change it to gauge pressure (gauge).
Open the tank shut valves of the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly.
If the Data List item "Medium-range Hydrogen Pressure (gauge)" decreases to below 0.7 MPa (7.1 kgf/cm2, 102 psi) the tank shut valves of the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly will forcibly close.
If the tank shut valves of the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly do not open, open the tank shut valves again.
| *a | SST (Venting Stand) |
Open the open/close valve of SST (venting stand), and depressurize compressed hydrogen gas.
Continue to monitor the Data List, and when the value of "Medium-range Hydrogen Pressure (gauge)" becomes 0.8 MPa (8.2 kgf/cm2, 116 psi), close the open/close valve of SST (venting stand).
To protect the tank shut valve, make sure to first close the open/close valve of SST (venting stand).
Forgetting to close the open/close valve of SST (venting stand) and allowing the Data List item "Medium-range Hydrogen Pressure (gauge)" to decrease to below 0.7 MPa (7.1 kgf/cm2, 102 psi) will cause the tank shut valves of the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly to forcibly close.
Check that the Data List item "Medium-range Hydrogen Pressure (gauge)" and the pressure on the pressure indicator of SST (venting stand) are less than 0.8 MPa (8.2 kgf/cm2, 116 psi).
The pressure immediately after closing the open/close valve of SST (venting stand) should be less than 0.8 MPa (8.2 kgf/cm2, 116 psi) for both the Data List item "Medium-range Hydrogen Pressure (gauge)" and on the pressure indicator of SST (venting stand).
If either the Data List item "Medium-range Hydrogen Pressure (gauge)" or the pressure on the pressure indicator of SST (venting stand) are 0.8 MPa (8.2 kgf/cm2, 116 psi) or greater, open the open/close valve of SST (venting stand) and adjust the pressure.
If the pressure immediately after closing the open/close valve of SST (venting stand) is less than 0.8 MPa (8.2 kgf/cm2, 116 psi) for both the Data List item "Medium-range Hydrogen Pressure (gauge)" and on the pressure indicator of SST (venting stand), then the pressurized hydrogen gas depressurizing procedure is complete.
Close the tank shut valves of both the No. 1 hydrogen tank assembly, No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly.
| *a | SST (Venting Stand) |
Open the open/close valve of SST (venting stand) and discharge the compressed hydrogen gas remaining inside SST (flexible hose).
Do not disconnect SST (flexible hose) while there is still pressure remaining inside it.
Continue discharging until the pressure gauge of SST (Venting Stand) becomes "0".
Before performing the disconnection procedure, if there are any contaminants such as water droplets adhering near the medium pressure leak check port of the hydrogen supply regulator, wipe them away before performing the procedure.
| *a | SST (Flexible Hose) |
| *b | SST (Venting Stand) |
Disconnect SST (flexible hose) from SST (Venting Stand).
for Type A:
| *a | SST (Flexible Hose) |
Remove SST (flexible hose) from the hydrogen supply regulator.
for Type B:
| *a | SST (Flexible Hose) |
Loosen SST (flexible hose).
Remove the 3 bolts of the hydrogen supply regulator.
| *a | SST (Flexible Hose) |
Remove SST (flexible hose) from the hydrogen supply regulator.
Install the hydrogen supply regulator with the 3 bolts.
Remove the O-ring from the hydrogen supply regulator.
| *a | Protective Tape |
To prevent damage to the seal portions and threaded portions, and to prevent foreign matter such as dust or metal fragments from entering the openings, cover the seal portions, threaded portions, and openings of the hydrogen supply regulator with protective tape.
To prevent damage to the seal portions and threaded portions, and to prevent foreign matter such as dust or metal fragments from entering the openings, do not remove the protective tape covering the seal portions, threaded portions, and openings of the hydrogen supply regulator until immediately before performing work.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
Apply TOYOTA Genuine FC Grease to a new O-ring and to the threaded portion of the hydrogen supply regulator.
Install the O-ring to the hydrogen supply regulator.
During installation, make sure not to damage the O-ring.
| *a | Specified tightening torque |
Using SST install the No. 1 hydrogen supply regulator plug to the hydrogen supply regulator.
9.0 N*m (92 kgf*cm, 80 in.*lbf)
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 40 mm (1.57 in.)) + torque wrench (fulcrum length of 162 mm (6.38 in.)): 7.2 N*m (73 kgf*cm, 64 in.*lbf)