If fresh/recirculation mode changes unintentionally and without permission, the following causes are possible.
| Symptom | Factor |
|---|---|
·
Fresh/recirculation mode changes without permission ·
Fresh/recirculation mode light blinks |
·
Customize setting ·
Change in fresh air temperature ·
Refrigerant pressure drop ·
Pressure sensor circuit malfunction ·
High FC stack outlet coolant temperature |
Use the following customize setting methods to confirm that the automatically fresh/recirculation mode is "ON". If the setting is on, select the setting to "OFF".
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>CUSTOMIZE PARAMETERS
Customize setting is "OFF".
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Thermistor assembly system malfunction
·
When open circuit: -23.30°C (-9.94°F) ·
When short circuit: 65.95°C (150.71°F) |
| Tester Display |
|---|
| Ambient Temp Sensor |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| FC Stack Outlet Coolant Temperature (Filtered Value) | FC stack outlet coolant temperature | -40°C (-40°F) to 215.9 °C (421 °F) | 50 to 85 °C (122 to 185 °F): After warming up | - |
| Tester Display |
|---|
| FC Stack Outlet Coolant Temperature (Filtered Value) |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.68 kPaG
Max.: 3294.37 kPaG |
Actual refrigerant pressure displayed | Air conditioner pressure sensor system malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Read the manifold gauge pressure when the following conditions are met.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Door | Fully closed (windows also fully closed) |
| A/C Switch | On |
| Recirculation/fresh Control Switch | Recirculation |
| Set Temperature | MAX COLD |
| Blower Speed | HI |
| Air Conditioning Air Inlet Temperature | 25 to 35°C (77 to 95°F) |
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
Compare the values displayed in the Data List and on the manifold gauge.
The values displayed in the Data List and on the manifold gauge match.
| Proceed to |
|---|
| OK |
| NG |
OK
NG