The hydrogen secondary pressure sensor is provided on the hydrogen supply secondary pipe sub-assembly, and it detects and converts hydrogen pressure in the hydrogen circulation system (low-range pressure system) into voltage values.
The FC control ECU checks for leaks in the hydrogen circulation system (low-range pressure system) when the FC system is activated, and monitors hydrogen pressure in the hydrogen circulation system while the FC is in operation, though use of hydrogen secondary pressure sensor values.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1DBA11 | Low-Range Hydrogen Pressure Sensor Circuit Short to Ground | If the +B voltage is not low when the ignition switch is ON, the output voltage of the hydrogen secondary pressure sensor circuit remains at less than 0.30 V for more than 3 seconds.
(1 trip detection logic) |
·
Hydrogen secondary pressure sensor ·
FC control ECU ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| P1DBA15 | Low-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open | If the +B voltage is not low when the ignition switch is ON, the output voltage of the hydrogen secondary pressure sensor circuit remains at more than 4.87 V for more than 3 seconds.
(1 trip detection logic) |
·
Hydrogen secondary pressure sensor ·
FC control ECU ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List (EV)
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List (EV)
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | ○ | ○ | ○ | ○ | ○ | - |
| DTC No. | Data List |
|---|---|
| P1DBA11 | Low-Range Hydrogen Pressure Sensor Voltage |
| P1DBA15 |
If DTCs are found, read the "Low-Range Hydrogen Pressure Sensor Voltage" in the Data List on a GTS.
| Low-Range Hydrogen Pressure Sensor Voltage | Malfunction |
|---|---|
| Less than 0.30 V | ·
Open in VHPL (5 V power supply) circuit ·
Short in HPL circuit to ground ·
Short in APFC circuit to GHPL (GND) circuit |
| Higher than 4.87 V | ·
Short in VHPL circuit to APFC circuit ·
Open in HPL circuit ·
Open in GHPL (GND) circuit ·
Short in VHPL circuit to ground |
It is suspected that malfunctions, or open/short circuits have occurred in the hydrogen secondary pressure sensor.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON and wait for 3 seconds or more.
Pre-procedure1
Disconnect the hydrogen secondary pressure sensor connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B11)Location & Routingewd_type=routing;type=c;code=B11 Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensorewd_type=component;type=c;code=B11;pinno=3,1,2 |
||
| B11-3 (VHPL) - B11-1 (GHPL) | Ignition switch ON | 4.75 to 5.25 V |
| B11-2 (HPL) - B11-1 (GHPL) | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the hydrogen secondary pressure sensor connector.
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the hydrogen secondary pressure sensor connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B1,B11)Location & Routingewd_type=routing;type=c,c;code=B1,B11 Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECUewd_type=component;type=c;code=B1;pinno=67,66,68 Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensorewd_type=component;type=c;code=B11;pinno=2,1,3 |
||
| B1-67 (HPL) - B11-2 (HPL) | Always | Below 1 Ω |
| B1-66 (GHPL) - B11-1 (GHPL) | Always | Below 1 Ω |
| B1-68 (VHPL) - B11-3 (VHPL) | Always | Below 1 Ω |
| B1-67 (HPL) or B11-2 (HPL) - Body ground and other terminals | Always | 10 kΩ or higher |
| B1-68 (VHPL) or B11-3 (VHPL) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen secondary pressure sensor connector.
Reconnect the FC control ECU connector.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Pre-procedure1
Turn the ignition switch to ON and wait for 3 seconds or more.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1DBA11 or P1DBA15 is output | A |
| DTCs are not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
Disconnect the hydrogen secondary pressure sensor connector.
Disconnect the hydrogen primary pressure sensor connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B11)Location & Routingewd_type=routing;type=c;code=B11 Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensorewd_type=component;type=c;code=B11;pinno=3,1,2 |
||
| B11-3 (VHPL) - B11-1 (GHPL) | Ignition switch ON | 4.75 to 5.25 V |
| B11-2 (HPL) - B11-1 (GHPL) | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the hydrogen primary pressure sensor connector.
Reconnect the hydrogen secondary pressure sensor connector.
OK
NG
Pre-procedure1
Disconnect the hydrogen secondary pressure sensor connector.
Disconnect the hydrogen tank pressure sensor (for outlet side) connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B11)Location & Routingewd_type=routing;type=c;code=B11 Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensorewd_type=component;type=c;code=B11;pinno=3,1,2 |
||
| B11-3 (VHPL) - B11-1 (GHPL) | Ignition switch ON | 4.75 to 5.25 V |
| B11-2 (HPL) - B11-1 (GHPL) | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the hydrogen tank pressure sensor (for outlet side) connector.
Reconnect the hydrogen secondary pressure sensor connector.
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the hydrogen secondary pressure sensor connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B1,B11)Location & Routingewd_type=routing;type=c,c;code=B1,B11 Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECUewd_type=component;type=c;code=B1;pinno=67,66,68 Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensorewd_type=component;type=c;code=B11;pinno=2,1,3 |
||
| B1-67 (HPL) - B11-2 (HPL) | Always | Below 1 Ω |
| B1-66 (GHPL) - B11-1 (GHPL) | Always | Below 1 Ω |
| B1-68 (VHPL) - B11-3 (VHPL) | Always | Below 1 Ω |
| B1-67 (HPL) or B11-2 (HPL) - Body ground and other terminals | Always | 10 kΩ or higher |
| B1-68 (VHPL) or B11-3 (VHPL) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen secondary pressure sensor connector.
Reconnect the FC control ECU connector.
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the hydrogen primary pressure sensor connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B1,B10)Location & Routingewd_type=routing;type=c,c;code=B1,B10 Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECUewd_type=component;type=c;code=B1;pinno=114 Click Connector(B10)Engine Compartment>No. 2 Stack Wire>Hydrogen Primary Pressure Sensorewd_type=component;type=c;code=B10;pinno=3 |
||
| B1-114 (VHPM) - B10-3 (VHPM) | Always | Below 1 Ω |
| B1-114 (VHPM) or B10-3 (VHPM) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen primary pressure sensor connector.
Reconnect the FC control ECU connector.
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the hydrogen tank pressure sensor (for outlet side) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B1,G7)Location & Routingewd_type=routing;type=c,c;code=B1,G7 Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECUewd_type=component;type=c;code=B1;pinno=115 Click Connector(G7)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Tank Pressure Sensorewd_type=component;type=c;code=G7;pinno=3 |
||
| B1-115 (VHPT) - G7-3 (VHPT) | Always | Below 1 Ω |
| B1-115 (VHPT) or G7-3 (VHPT) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen tank pressure sensor (for outlet side) connector.
Reconnect the FC control ECU connector.
OK
NG