Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1DBA11  Low-Range Hydrogen Pressure Sensor Circuit Short to Ground  P1DBA15  Low-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open  


DESCRIPTION

The hydrogen secondary pressure sensor is provided on the hydrogen supply secondary pipe sub-assembly, and it detects and converts hydrogen pressure in the hydrogen circulation system (low-range pressure system) into voltage values.

The FC control ECU checks for leaks in the hydrogen circulation system (low-range pressure system) when the FC system is activated, and monitors hydrogen pressure in the hydrogen circulation system while the FC is in operation, though use of hydrogen secondary pressure sensor values.

A477005E03
0.073,0.094 1.427,0.958 1.354,0.865 10 false Reference: Hydrogen Secondary Pressure Sensor Characteristic Graph 1.813,0.073 2.583,0.271 0.771,0.198 10 false Voltage (V) 5,1.865 5.771,2.063 0.771,0.198 10 false kPa (abs) 5,2.323 5.875,2.542 0.875,0.219 10 false psi (abs) 2.042,0.365 2.427,0.563 0.385,0.198 10 false 4.7 2.042,0.656 2.542,0.854 0.5,0.198 10 false 4.5 2.042,1.031 2.542,1.229 0.5,0.198 10 false 2.5 2.031,1.552 2.531,1.75 0.5,0.198 10 false 0.5 2.031,1.74 2.531,1.938 0.5,0.198 10 false 0.3 2.771,2 3.271,2.198 0.5,0.198 10 false 31.3 2.417,1.99 2.917,2.188 0.5,0.198 10 false 11.8 3.417,2 3.917,2.198 0.5,0.198 10 false 228.3 4.01,2 4.51,2.198 0.5,0.198 10 false 421.3 4.458,2 4.958,2.198 0.5,0.198 10 false 440.8 2.333,2.479 2.833,2.677 0.5,0.198 10 false 1.711 2.719,2.479 3.219,2.677 0.5,0.198 10 false 4.539 3.427,2.469 3.927,2.667 0.5,0.198 10 false 33.104 3.99,2.469 4.49,2.667 0.5,0.198 10 false 61.089 4.469,2.469 4.969,2.667 0.5,0.198 10 false 63.916

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1DBA11 Low-Range Hydrogen Pressure Sensor Circuit Short to Ground If the +B voltage is not low when the ignition switch is ON, the output voltage of the hydrogen secondary pressure sensor circuit remains at less than 0.30 V for more than 3 seconds.
(1 trip detection logic)
·

Hydrogen secondary pressure sensor

·

FC control ECU

·

Wire harness or connector


Master Warning: Comes on FC A
P1DBA15 Low-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open If the +B voltage is not low when the ignition switch is ON, the output voltage of the hydrogen secondary pressure sensor circuit remains at more than 4.87 V for more than 3 seconds.
(1 trip detection logic)
·

Hydrogen secondary pressure sensor

·

FC control ECU

·

Wire harness or connector


Master Warning: Comes on FC A

Detection timing
Vehicle Condition FC shutdown
(ignition switch ON)
FC startup process FC intermittent operation FC is generating power
(vehicle is in stationary)
FC is generating power
(vehicle is traveling)
FC shutdown process
Data List (EV)
"FC Work Mode"
Stop Startup Working Finishing
Data List (EV)
"FC Intermittent Operation"
OFF ON OFF OFF
DTC Detection ○ ○ ○ ○ ○ -

Related Data List
DTC No. Data List
P1DBA11 Low-Range Hydrogen Pressure Sensor Voltage
P1DBA15

HINT:

If DTCs are found, read the "Low-Range Hydrogen Pressure Sensor Voltage" in the Data List on a GTS.


Low-Range Hydrogen Pressure Sensor Voltage Malfunction
Less than 0.30 V
·

Open in VHPL (5 V power supply) circuit

·

Short in HPL circuit to ground

·

Short in APFC circuit to GHPL (GND) circuit


Higher than 4.87 V
·

Short in VHPL circuit to APFC circuit

·

Open in HPL circuit

·

Open in GHPL (GND) circuit

·

Short in VHPL circuit to ground



HINT:

It is suspected that malfunctions, or open/short circuits have occurred in the hydrogen secondary pressure sensor.


CAUTION / NOTICE / HINT

NOTICE:
·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the ignition switch to ON and wait for 3 seconds or more.



PROCEDURE

1.CHECK TERMINAL VOLTAGE (POWER SOURCE OF HYDROGEN SECONDARY PRESSURE SENSOR)

Pre-procedure1

a.
A476941

Disconnect the hydrogen secondary pressure sensor connector.


b.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(B11)Location & Routing

Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensor

B11-3 (VHPL) - B11-1 (GHPL) Ignition switch ON 4.75 to 5.25 V
B11-2 (HPL) - B11-1 (GHPL) Ignition switch ON 4.75 to 5.25 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen secondary pressure sensor connector.



OK

2.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN SECONDARY PRESSURE SENSOR)

NG

6.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF HYDROGEN SECONDARY PRESSURE SENSOR)
2.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN SECONDARY PRESSURE SENSOR)

Pre-procedure1

a.

Disconnect the FC control ECU connector.


b.

Disconnect the hydrogen secondary pressure sensor connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B1,B11)Location & Routing

Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECU

Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensor

B1-67 (HPL) - B11-2 (HPL) Always Below 1 Ω
B1-66 (GHPL) - B11-1 (GHPL) Always Below 1 Ω
B1-68 (VHPL) - B11-3 (VHPL) Always Below 1 Ω
B1-67 (HPL) or B11-2 (HPL) - Body ground and other terminals Always 10 kΩ or higher
B1-68 (VHPL) or B11-3 (VHPL) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen secondary pressure sensor connector.


b.

Reconnect the FC control ECU connector.



OK

3.REPLACE HYDROGEN SECONDARY PRESSURE SENSOR

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.REPLACE HYDROGEN SECONDARY PRESSURE SENSOR

NEXT

4.CLEAR DTC
4.CLEAR DTC

Pre-procedure1

a.

None


Procedure1

a.

Clear the DTCs.

Powertrain > FC > Clear DTCs
50002 490
Result:
Proceed to
NEXT



Post-procedure1

a.

Turn the ignition switch off and wait for 10 minutes or more.



NEXT

5.CHECK DTC OUTPUT
5.CHECK DTC OUTPUT

Pre-procedure1

a.

Turn the ignition switch to ON and wait for 3 seconds or more.


Procedure1

a.

Check for DTCs.

Powertrain > FC > Trouble Codes
50001 490
Result:
Result Proceed to
P1DBA11 or P1DBA15 is output A
DTCs are not output B



Post-procedure1

a.

Turn the ignition switch off.



A

B

END

6.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF HYDROGEN SECONDARY PRESSURE SENSOR)

Pre-procedure1

a.

Disconnect the hydrogen secondary pressure sensor connector.


b.
A478999

Disconnect the hydrogen primary pressure sensor connector.


c.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(B11)Location & Routing

Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensor

B11-3 (VHPL) - B11-1 (GHPL) Ignition switch ON 4.75 to 5.25 V
B11-2 (HPL) - B11-1 (GHPL) Ignition switch ON 4.75 to 5.25 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen primary pressure sensor connector.


c.

Reconnect the hydrogen secondary pressure sensor connector.



OK

REPLACE HYDROGEN PRIMARY PRESSURE SENSOR

NG

7.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF HYDROGEN SECONDARY PRESSURE SENSOR)
7.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF HYDROGEN SECONDARY PRESSURE SENSOR)

Pre-procedure1

a.

Disconnect the hydrogen secondary pressure sensor connector.


b.
A476959

Disconnect the hydrogen tank pressure sensor (for outlet side) connector.


c.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(B11)Location & Routing

Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensor

B11-3 (VHPL) - B11-1 (GHPL) Ignition switch ON 4.75 to 5.25 V
B11-2 (HPL) - B11-1 (GHPL) Ignition switch ON 4.75 to 5.25 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen tank pressure sensor (for outlet side) connector.


c.

Reconnect the hydrogen secondary pressure sensor connector.



OK

REPLACE HYDROGEN TANK TUBE JOINT ASSEMBLY (HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

NG

8.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN SECONDARY PRESSURE SENSOR)
8.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN SECONDARY PRESSURE SENSOR)

Pre-procedure1

a.

Disconnect the FC control ECU connector.


b.

Disconnect the hydrogen secondary pressure sensor connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B1,B11)Location & Routing

Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECU

Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensor

B1-67 (HPL) - B11-2 (HPL) Always Below 1 Ω
B1-66 (GHPL) - B11-1 (GHPL) Always Below 1 Ω
B1-68 (VHPL) - B11-3 (VHPL) Always Below 1 Ω
B1-67 (HPL) or B11-2 (HPL) - Body ground and other terminals Always 10 kΩ or higher
B1-68 (VHPL) or B11-3 (VHPL) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen secondary pressure sensor connector.


b.

Reconnect the FC control ECU connector.



OK

9.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN PRIMARY PRESSURE SENSOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN PRIMARY PRESSURE SENSOR)

Pre-procedure1

a.

Disconnect the FC control ECU connector.


b.

Disconnect the hydrogen primary pressure sensor connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B1,B10)Location & Routing

Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECU

Click Connector(B10)Engine Compartment>No. 2 Stack Wire>Hydrogen Primary Pressure Sensor

B1-114 (VHPM) - B10-3 (VHPM) Always Below 1 Ω
B1-114 (VHPM) or B10-3 (VHPM) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen primary pressure sensor connector.


b.

Reconnect the FC control ECU connector.



OK

10.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

Pre-procedure1

a.

Disconnect the FC control ECU connector.


b.

Disconnect the hydrogen tank pressure sensor (for outlet side) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B1,G7)Location & Routing

Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECU

Click Connector(G7)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Tank Pressure Sensor

B1-115 (VHPT) - G7-3 (VHPT) Always Below 1 Ω
B1-115 (VHPT) or G7-3 (VHPT) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen tank pressure sensor (for outlet side) connector.


b.

Reconnect the FC control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR