Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1E0012  Tank Shut Valve 1 Circuit Short to Battery  P1E1012  Tank Shut Valve 2 Circuit Short to Battery  P1E5A12  Tank Shut Valve 3 Circuit Short to Battery  


DESCRIPTION

The tank shut valve is built into the hydrogen tank assembly so as to feed or shut off compressed hydrogen from the hydrogen tank to the FC stack. Actuation requests are made by the EV control ECU, and the hydrogen fuel control ECU receives such requests through CAN communication, and then actuates the tank shut valve. The hydrogen fuel control ECU uses the inrush current circuit when opening the valve, and uses the PWM circuit when holding the valve.

The hydrogen fuel control ECU detects abnormalities by monitoring valve actuation voltages.

The EV control ECU operates the H2 SHUT VLV relay.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1E0012 Tank Shut Valve 1 Circuit Short to Battery H2 SHUT VLV relay has been requested to turn OFF, the tank shut valve 1 is driven to ON, and the TNV1 voltage has remained at more than 0.2 V for more than 3 seconds.
(1 trip detection logic)
·

No. 1 hydrogen tank assembly (tank shut valve 1)

·

Hydrogen fuel control ECU assembly

·

Wire harness or connector

·

EV control ECU

·

H2 SHUT VLV relay


Master Warning: Comes on Hydrogen Filling Control A
P1E1012 Tank Shut Valve 2 Circuit Short to Battery H2 SHUT VLV relay has been requested to turn OFF, the tank shut valve 2 is driven to ON, and the TNV2 voltage has remained at more than 0.2 V for more than 3 seconds.
(1 trip detection logic)
·

No. 2 hydrogen tank assembly (tank shut valve 2)

·

Hydrogen fuel control ECU assembly

·

Wire harness or connector

·

EV control ECU

·

H2 SHUT VLV relay


Master Warning: Comes on Hydrogen Filling Control A
P1E5A12 Tank Shut Valve 3 Circuit Short to Battery H2 SHUT VLV relay has been requested to turn OFF, the tank shut valve 3 is driven to ON, and the TNV3 voltage has remained at more than 0.2 V for more than 3 seconds.
(1 trip detection logic)
·

No. 3 hydrogen tank assembly (tank shut valve 3)

·

Hydrogen fuel control ECU assembly

·

Wire harness or connector

·

EV control ECU

·

H2 SHUT VLV relay


Master Warning: Comes on Hydrogen Filling Control A

Related Data List
DTC No. Data List
P1E0012
·

Tank Shut Valve 1 Voltage*1

·

Tank Shut Valve 1 Driving Request

·

Tank Shut Valve Power Supply Relay Driving Status*2


P1E1012
·

Tank Shut Valve 2 Voltage*1

·

Tank Shut Valve 2 Driving Request

·

Tank Shut Valve Power Supply Relay Driving Status*2


P1E5A12
·

Tank Shut Valve 3 Voltage*1

·

Tank Shut Valve 3 Driving Request

·

Tank Shut Valve Power Supply Relay Driving Status*2



*1: AD value for the TNV1, 2 and 3 terminals

*2: Actuation request to the power supply relay


WIRING DIAGRAM

A477010E02
0.833,2.49 1.917,2.875 1.083,0.385 10 false EV Control ECU 0.906,1.594 1.5,1.823 0.594,0.229 10 false RLTN 0.844,2.323 1.438,2.552 0.594,0.229 10 false A15 0.719,1.469 1.313,1.698 0.594,0.229 10 false 1 0.781,0.969 1.698,1.156 0.917,0.188 10 false H2 SHUT VLV 1.604,0.521 1.802,0.75 0.198,0.229 10 false 1 0.771,0.521 0.969,0.75 0.198,0.229 10 false 2 0.771,0.094 0.969,0.323 0.198,0.229 10 false 3 1.625,0.094 1.823,0.323 0.198,0.229 10 false 5 0.448,3.865 1.365,4.052 0.917,0.188 10 false H2 SHUT VLV 0.448,4.688 1.365,4.875 0.917,0.188 10 false R/B-B NO. 1 0.458,5.354 1.375,5.542 0.917,0.188 10 false R/B-FR 0.625,6.49 1.729,6.698 1.104,0.208 10 false Auxiliary Battery 0.385,7.396 1.615,7.583 1.229,0.188 10 false *: Shield Ground 1.958,6.708 2.281,6.917 0.323,0.208 10 false G4 4.323,6.688 4.646,6.896 0.323,0.208 10 false G4 4.333,6.26 4.656,6.469 0.323,0.208 10 false G5 4.323,5.885 4.646,6.094 0.323,0.208 10 false G5 1.99,6.531 2.25,6.75 0.26,0.219 10 false 32 2.281,6.719 2.542,6.938 0.26,0.219 10 false E1 4.385,5.698 4.583,5.927 0.198,0.229 10 false 1 4.385,6.5 4.583,6.729 0.198,0.229 10 false 1 4.385,6.083 4.583,6.313 0.198,0.229 10 false 2 3.885,5.792 4.292,6.021 0.406,0.229 10 false GTV1 3.885,6.167 4.292,6.396 0.406,0.229 10 false GTV2 3.875,6.573 4.281,6.802 0.406,0.229 10 false GTV3 2.094,7.167 5.104,7.406 3.01,0.24 10 false Hydrogen Fuel Control ECU Assembly 4.333,5.427 4.656,5.635 0.323,0.208 10 false G4 4.333,5.052 4.656,5.26 0.323,0.208 10 false G4 4.385,4.854 4.583,5.083 0.198,0.229 10 false 2 4.396,5.25 4.594,5.479 0.198,0.229 10 false 4 3.875,5.427 4.281,5.656 0.406,0.229 10 false VDR3 3.885,4.958 4.292,5.188 0.406,0.229 10 false TNV3 5.49,5.208 6.802,5.385 1.313,0.177 10 false Tank Shut Valve 3 5.104,5.719 7.063,5.938 1.958,0.219 10 false No. 3 Hydrogen Tank Assembly 4.906,5.563 5.104,5.792 0.198,0.229 10 false * 5.396,4.969 5.802,5.198 0.406,0.229 10 false TNV3 6.313,4.958 6.719,5.188 0.406,0.229 10 false TVR3 6.76,4.958 6.958,5.188 0.198,0.229 10 false 4 5.198,4.948 5.396,5.177 0.198,0.229 10 false 6 4.333,4.125 4.656,4.333 0.323,0.208 10 false G5 4.333,3.75 4.656,3.958 0.323,0.208 10 false G5 3.896,4.125 4.302,4.354 0.406,0.229 10 false VDR2 3.885,3.677 4.292,3.906 0.406,0.229 10 false TNV2 4.875,4.24 5.073,4.469 0.198,0.229 10 false * 5.094,4.438 7.156,4.656 2.063,0.219 10 false No. 2 Hydrogen Tank Assembly 5.5,3.896 6.813,4.073 1.313,0.177 10 false Tank Shut Valve 2 6.302,3.625 6.708,3.854 0.406,0.229 10 false TVR2 5.417,3.635 5.823,3.865 0.406,0.229 10 false TNV2 6.74,3.625 6.938,3.854 0.198,0.229 10 false 4 5.229,3.635 5.427,3.865 0.198,0.229 10 false 6 4.333,2.802 4.656,3.01 0.323,0.208 10 false G5 4.333,2.438 4.656,2.646 0.323,0.208 10 false G5 4.375,3.938 4.573,4.167 0.198,0.229 10 false 4 4.365,3.552 4.563,3.781 0.198,0.229 10 false 7 5.094,3.115 7.052,3.333 1.958,0.219 10 false No. 1 Hydrogen Tank Assembly 5.458,2.563 6.771,2.74 1.313,0.177 10 false Tank Shut Valve 1 3.875,2.292 4.281,2.521 0.406,0.229 10 false TNV1 5.417,2.313 5.823,2.542 0.406,0.229 10 false IB9 6.448,2.323 6.854,2.552 0.406,0.229 10 false IB8 6.75,2.313 6.948,2.542 0.198,0.229 10 false 4 5.219,2.313 5.417,2.542 0.198,0.229 10 false 6 3.875,2.802 4.281,3.031 0.406,0.229 10 false VDR1 4.375,2.24 4.573,2.469 0.198,0.229 10 false 6 4.333,2.635 4.531,2.865 0.198,0.229 10 false 18 4.854,2.938 5.083,3.24 0.229,0.302 10 false * 2.438,0.76 3.427,1.188 0.99,0.427 10 false Valve Actuation Voltage Monitor 3.958,0.719 4.365,0.948 0.406,0.229 10 false +BP 3.885,1.094 4.292,1.323 0.406,0.229 10 false PDR1 3.875,1.5 4.281,1.729 0.406,0.229 10 false +BP2 3.865,1.875 4.271,2.104 0.406,0.229 10 false PDR2 4.896,1.979 5.125,2.281 0.229,0.302 10 false * 4.885,1.208 5.115,1.51 0.229,0.302 10 false * 4.344,0.698 4.667,0.906 0.323,0.208 10 false G5 4.344,1.083 4.667,1.292 0.323,0.208 10 false G5 4.333,1.479 4.656,1.688 0.323,0.208 10 false G4 4.333,1.854 4.656,2.063 0.323,0.208 10 false G4 4.344,0.521 4.542,0.75 0.198,0.229 10 false 20 4.354,0.906 4.552,1.135 0.198,0.229 10 false 17 4.375,1.292 4.573,1.521 0.198,0.229 10 false 3 4.344,1.677 4.542,1.906 0.198,0.229 10 false 30 5.104,2.969 5.51,3.198 0.406,0.229 10 false h1 5.083,4.281 5.49,4.51 0.406,0.229 10 false G3 5.094,5.583 5.5,5.813 0.406,0.229 10 false G1

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses of circuits related to this system before performing the following procedure.

·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the ignition switch to ON (READY).

2.

Turn the ignition switch off and wait for 10 minutes or more.



PROCEDURE

1.READ VALUE USING GTS (TANK SHUT VALVE 1 VOLTAGE)

Pre-procedure1

a.

Remove the H2 SHUT VLV relay from the No. 1 front compartment relay block.


Procedure1

a.

Read the value displayed on the GTS.

Powertrain > Hydrogen Filling Control > Data List
Tester Display
Tank Shut Valve 1 Voltage
50003 494 24
Result:
Result Proceed to
The value of Tank Shut Valve 1 Voltage is 0.2 V or more A
The value of Tank Shut Valve 1 Voltage is less than 0.2 V B


HINT:

If there is a +B short circuit, the GTS indicates 0.2 V or more.



Post-procedure1

a.

Turn the ignition switch off.


b.

Reinstall the H2 SHUT VLV relay.



A

2.READ VALUE USING GTS (TANK SHUT VALVE 2 VOLTAGE)

B

12.INSPECT RELAY (H2 SHUT VLV RELAY)
2.READ VALUE USING GTS (TANK SHUT VALVE 2 VOLTAGE)

Pre-procedure1

a.

Remove the H2 SHUT VLV relay from the No. 1 front compartment relay block.


Procedure1

a.

Read the value displayed on the GTS.

Powertrain > Hydrogen Filling Control > Data List
Tester Display
Tank Shut Valve 2 Voltage
50003 494 25
Result:
Result Proceed to
The value of Tank Shut Valve 2 Voltage is 0.2 V or more A
The value of Tank Shut Valve 2 Voltage is less than 0.2 V B


HINT:

If there is a +B short circuit, the GTS indicates 0.2 V or more.



Post-procedure1

a.

Turn the ignition switch off.


b.

Reinstall the H2 SHUT VLV relay.



A

3.READ VALUE USING GTS (TANK SHUT VALVE 3 VOLTAGE)

B

12.INSPECT RELAY (H2 SHUT VLV RELAY)
3.READ VALUE USING GTS (TANK SHUT VALVE 3 VOLTAGE)

Pre-procedure1

a.

Remove the H2 SHUT VLV relay from the No. 1 front compartment relay block.


Procedure1

a.

Read the value displayed on the GTS.

Powertrain > Hydrogen Filling Control > Data List
Tester Display
Tank Shut Valve 3 Voltage
50003 494 29
Result:
Result Proceed to
The value of Tank Shut Valve 3 Voltage is 0.2 V or more A
The value of Tank Shut Valve 3 Voltage is less than 0.2 V B


HINT:

If there is a +B short circuit, the GTS indicates 0.2 V or more.



Post-procedure1

a.

Turn the ignition switch off.


b.

Reinstall the H2 SHUT VLV relay.



A

4.CHECK TERMINAL VOLTAGE (+BP, +BP2, TNV1, TNV2, TNV3)

B

12.INSPECT RELAY (H2 SHUT VLV RELAY)
4.CHECK TERMINAL VOLTAGE (+BP, +BP2, TNV1, TNV2, TNV3)

Pre-procedure1

a.

Remove the H2 SHUT VLV relay from the No. 1 front compartment relay block.


b.

Disconnect the hydrogen fuel control ECU assembly connector.


c.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G5,G4)Location & Routing

Click Connector(G5)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

Click Connector(G4)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

G5-20 (+BP) - G4-32 (E1) Ignition switch ON Below 1 V
G4-3 (+BP2) - G4-32 (E1) Ignition switch ON Below 1 V
G5-6 (TNV1) - G4-32 (E1) Ignition switch ON Below 1 V
G5-7 (TNV2) - G4-32 (E1) Ignition switch ON Below 1 V
G4-2 (TNV3) - G4-32 (E1) Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen fuel control ECU assembly connector.


c.

Reinstall the H2 SHUT VLV relay.



OK

REPLACE HYDROGEN FUEL CONTROL ECU ASSEMBLY

NG

5.CHECK HARNESS AND CONNECTOR (H2 SHUT VLV RELAY - HYDROGEN FUEL CONTROL ECU ASSEMBLY)
5.CHECK HARNESS AND CONNECTOR (H2 SHUT VLV RELAY - HYDROGEN FUEL CONTROL ECU ASSEMBLY)

Pre-procedure1

a.

Remove the H2 SHUT VLV relay from the No. 1 front compartment relay block.


b.

Disconnect the hydrogen fuel control ECU assembly connector.


c.
A476963

Disconnect the No. 1 hydrogen tank assembly (tank shut valve 1) connector.


d.
A476964

Disconnect the No. 2 hydrogen tank assembly (tank shut valve 2) connector.


e.
A476966

Disconnect the No. 3 hydrogen tank assembly (tank shut valve 3) connector.


f.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G5,G4)Location & Routing

Click Connector(G5)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

Click Connector(G4)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

G5-20 (+BP) - G4-32 (E1) Ignition switch ON Below 1 V
G4-3 (+BP2) - G4-32 (E1) Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the No. 1 hydrogen tank assembly (tank shut valve 1) connector.


c.

Reconnect the No. 2 hydrogen tank assembly (tank shut valve 2) connector.


d.

Reconnect the No. 3 hydrogen tank assembly (tank shut valve 3) connector.


e.

Reinstall the H2 SHUT VLV relay.


f.

Reconnect the hydrogen fuel control ECU assembly connector.



OK

6.CHECK HARNESS AND CONNECTOR (HYDROGEN FUEL CONTROL ECU ASSEMBLY - NO. 1 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 1))

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (HYDROGEN FUEL CONTROL ECU ASSEMBLY - NO. 1 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 1))

Pre-procedure1

a.

Disconnect the hydrogen fuel control ECU assembly connector.


b.

Disconnect the No. 1 hydrogen tank assembly (tank shut valve 1) connector.


c.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G5,G4)Location & Routing

Click Connector(G5)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

Click Connector(G4)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

G5-6 (TNV1) - G4-32 (E1) Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the No. 1 hydrogen tank assembly (tank shut valve 1) connector.


c.

Reconnect the hydrogen fuel control ECU assembly connector.



OK

7.CHECK HARNESS AND CONNECTOR (HYDROGEN FUEL CONTROL ECU ASSEMBLY - NO. 2 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 2))

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (HYDROGEN FUEL CONTROL ECU ASSEMBLY - NO. 2 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 2))

Pre-procedure1

a.

Disconnect the hydrogen fuel control ECU assembly connector.


b.

Disconnect the No. 2 hydrogen tank assembly (tank shut valve 2) connector.


c.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G5,G4)Location & Routing

Click Connector(G5)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

Click Connector(G4)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

G5-7 (TNV2) - G4-32 (E1) Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the No. 2 hydrogen tank assembly (tank shut valve 2) connector.


c.

Reconnect the hydrogen fuel control ECU assembly connector.



OK

8.CHECK HARNESS AND CONNECTOR (HYDROGEN FUEL CONTROL ECU ASSEMBLY - NO. 3 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 3))

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK HARNESS AND CONNECTOR (HYDROGEN FUEL CONTROL ECU ASSEMBLY - NO. 3 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 3))

Pre-procedure1

a.

Disconnect the hydrogen fuel control ECU assembly connector.


b.

Disconnect the No. 3 hydrogen tank assembly (tank shut valve 3) connector.


c.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G4)Location & Routing

Click Connector(G4)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

G4-2 (TNV3) - G4-32 (E1) Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the No. 3 hydrogen tank assembly (tank shut valve 3) connector.


c.

Reconnect the hydrogen fuel control ECU assembly connector.



OK

9.CHECK NO. 1 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 1)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.CHECK NO. 1 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 1)

Pre-procedure1

a.

Disconnect the No. 1 hydrogen tank assembly (tank shut valve 1) connector.


b.

Turn the ignition switch to ON.


Procedure1

a.
A335327C09
2.01,1.188 2.344,1.615 true 2.396,1.573 3.094,1.781 0.698,0.208 10 false IB8 0.135,0.104 0.448,0.302 0.313,0.198 10 false *a
*a Component without harness connected
(No. 1 Hydrogen Tank Assembly (Tank Shut Valve 1))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
4 (IB8) - Body ground Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Reconnect the No. 1 hydrogen tank assembly (tank shut valve 1) connector.



OK

10.CHECK NO. 2 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 2)

NG

REPLACE HYDROGEN TANK ASSEMBLY NO.1 (TANK SHUT VALVE 1)

10.CHECK NO. 2 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 2)

Pre-procedure1

a.

Disconnect the No. 2 hydrogen tank assembly (tank shut valve 2) connector.


b.

Turn the ignition switch to ON.


Procedure1

a.
A335327C07
2.01,1.188 2.344,1.615 true 2.396,1.594 3.094,1.802 0.698,0.208 10 false TVR2 0.135,0.104 0.448,0.302 0.313,0.198 10 false *a
*a Component without harness connected
(No. 2 Hydrogen Tank Assembly (Tank Shut Valve 2))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
4 (TVR2) - Body ground Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Reconnect the No. 2 hydrogen tank assembly (tank shut valve 2) connector.



OK

11.CHECK NO. 3 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 3)

NG

REPLACE NO. 2 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 2)

11.CHECK NO. 3 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 3)

Pre-procedure1

a.

Disconnect the No. 3 hydrogen tank assembly (tank shut valve 3) connector.


b.

Turn the ignition switch to ON.


Procedure1

a.
A335327C08
2.01,1.188 2.344,1.615 true 2.396,1.594 3.094,1.802 0.698,0.208 10 false TVR3 0.135,0.104 0.448,0.302 0.313,0.198 10 false *a
*a Component without harness connected
(No. 3 Hydrogen Tank Assembly (Tank Shut Valve 3))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
4 (TVR3) - Body ground Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Reconnect the No. 3 hydrogen tank assembly (tank shut valve 3) connector.



OK

REPLACE HYDROGEN FUEL CONTROL ECU ASSEMBLY

NG

REPLACE NO. 3 HYDROGEN TANK ASSEMBLY (TANK SHUT VALVE 3)

12.INSPECT RELAY (H2 SHUT VLV RELAY)

Click hereEngine / Hybrid System>FUEL>RELAY>ON-VEHICLE INSPECTION

Result:
Proceed to
OK
NG



OK

13.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - H2 SHUT VLV RELAY)

NG

REPLACE RELAY (H2 SHUT VLV RELAY)

13.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - H2 SHUT VLV RELAY)

Pre-procedure1

a.

Remove the H2 SHUT VLV relay from the No. 1 front compartment relay block.


b.

Disconnect the EV control ECU connector.


c.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(A15,A17)Location & Routing

Click Connector(A15)Instrument Panel>Front Compartment Main Wire>EV Control ECU

Click Connector(A17)Instrument Panel>Front Compartment Main Wire>EV Control ECU

A15-1 (RLTN) - A17-4 (E1) Ignition switch ON Below 1 V



Result:
Proceed to
OK
NG


Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the EV control ECU connector.


c.

Reinstall the H2 SHUT VLV relay.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR