Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1E6B73  Fuel Lid Interlock Actuator Stuck Closed  


DESCRIPTION

If the fuel lid with motor lock assembly (interlock switch) signal indicates that the fuel lid is closed although the hydrogen tank internal pressure is increasing due to hydrogen filling, the EV control ECU interprets it as a malfunction of the fuel lid with motor lock assembly (interlock switch) circuit, and stores this DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1E6B73 Fuel Lid Interlock Actuator Stuck Closed While a fuel lid with motor lock assembly (interlock switch) close signal is input, the hydrogen tank internal pressure increases by more than 10 MPa due to hydrogen filling.
(1 trip detection logic)
·

Fuel lid with motor lock assembly (interlock switch)

·

EV control ECU

·

Wire harness or connector


Master Warning: Comes on EV A

Related Data List
DTC No. Data List
P1E6B73 Fuel Lid Interlock Switch

HINT:

It is suspected that there is a GND short in the fuel lid with motor lock assembly (interlock switch) circuit, or the fuel lid with motor lock assembly (interlock switch) has stuck closed.


WIRING DIAGRAM

A306470E36
4.99,0.823 5.604,1.021 0.615,0.198 10 false FILK 4.75,0.719 5.365,0.917 0.615,0.198 10 false 5 3.083,0.719 3.698,0.917 0.615,0.198 10 false B 2.427,0.719 3.042,0.917 0.615,0.198 10 false E 3.313,0.719 3.927,0.917 0.615,0.198 10 false 3 2.198,0.719 2.813,0.917 0.615,0.198 10 false 2 4.958,2.229 6.365,2.458 1.406,0.229 10 false EV Control ECU 4.969,2.083 5.583,2.281 0.615,0.198 10 false G14*1 1.875,1.344 4.073,1.781 2.198,0.438 10 false Fuel Lid with Motor Lock Assembly (Interlock Switch) 1.875,1.177 2.49,1.375 0.615,0.198 10 false G70 5.417,2.083 6.031,2.281 0.615,0.198 10 false A14*2 0.281,2.083 1.188,2.271 0.906,0.188 10 false *1: for LHD 0.281,2.417 1.188,2.604 0.906,0.188 10 false *2: for RHD

CAUTION / NOTICE / HINT

NOTICE:
·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:

After performing repairs, clear the DTCs, perform the following procedure, and then check the data list items "Fuel Lid Interlock SW".

1.

Turn the ignition switch off and press the fuel lid opener switch to open the fuel lid.

2.

Turn the ignition switch to ON.

3.

By referring to the table below, check that the "Fuel Lid Interlock SW" of the data list turns ON or OFF in accordance with the fuel lid operation.

Indication of the "Fuel Lid Interlock SW" in the data list
Fuel lid fully closed Fuel lid fully open
OFF ON



PROCEDURE

1.INSPECT FUEL LID WITH MOTOR LOCK ASSEMBLY (INTERLOCK SWITCH)

OK

2.CONFIRM MODEL

NG

REPLACE FUEL LID WITH MOTOR LOCK ASSEMBLY (INTERLOCK SWITCH)

2.CONFIRM MODEL
a.

Choose the model to be inspected.


Result:
Result Proceed to
for LHD A
for RHD B



A

3.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - FUEL LID WITH MOTOR LOCK ASSEMBLY (INTERLOCK SWITCH))

B

4.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - FUEL LID WITH MOTOR LOCK ASSEMBLY (INTERLOCK SWITCH))
3.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - FUEL LID WITH MOTOR LOCK ASSEMBLY (INTERLOCK SWITCH))

Pre-procedure1

a.

Disconnect the EV control ECU connector.


b.
A477021

Disconnect the fuel lid with motor lock assembly (interlock switch) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G70,G14)Location & Routing

Click Connector(G70)Body>Floor Wire / No. 3 Floor Wire>Fuel Lid Lock with Motor Assembly

Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECU

G70-3 (B) - G14-5 (FILK) Always Below 1 Ω
G70-3 (B) or G14-5 (FILK) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the fuel lid with motor lock assembly (interlock switch) connector.


b.

Reconnect the EV control ECU connector.



OK

5.CHECK HARNESS AND CONNECTOR (FUEL LID WITH MOTOR LOCK ASSEMBLY (INTERLOCK SWITCH) - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - FUEL LID WITH MOTOR LOCK ASSEMBLY (INTERLOCK SWITCH))

Pre-procedure1

a.

Disconnect the EV control ECU connector.


b.
A477021

Disconnect the fuel lid with motor lock assembly (interlock switch) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G70,A14)Location & Routing

Click Connector(G70)Body>Floor Wire / No. 3 Floor Wire>Fuel Lid Lock with Motor Assembly

Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECU

G70-3 (B) - A14-5 (FILK) Always Below 1 Ω
G70-3 (B) or A14-5 (FILK) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the fuel lid with motor lock assembly (interlock switch) connector.


b.

Reconnect the EV control ECU connector.



OK

5.CHECK HARNESS AND CONNECTOR (FUEL LID WITH MOTOR LOCK ASSEMBLY (INTERLOCK SWITCH) - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (FUEL LID WITH MOTOR LOCK ASSEMBLY (INTERLOCK SWITCH) - BODY GROUND)

Pre-procedure1

a.

Disconnect the fuel lid with motor lock assembly (interlock switch) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G70)Location & Routing

Click Connector(G70)Body>Floor Wire / No. 3 Floor Wire>Fuel Lid Lock with Motor Assembly

G70-2 (E) - Body ground Always Below 1 Ω


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the fuel lid with motor lock assembly (interlock switch) connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR