If the fuel lid with motor lock assembly (interlock switch) signal indicates that the fuel lid is closed although the hydrogen tank internal pressure is increasing due to hydrogen filling, the EV control ECU interprets it as a malfunction of the fuel lid with motor lock assembly (interlock switch) circuit, and stores this DTC.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1E6B73 | Fuel Lid Interlock Actuator Stuck Closed | While a fuel lid with motor lock assembly (interlock switch) close signal is input, the hydrogen tank internal pressure increases by more than 10 MPa due to hydrogen filling.
(1 trip detection logic) |
·
Fuel lid with motor lock assembly (interlock switch) ·
EV control ECU ·
Wire harness or connector |
Master Warning: Comes on | EV | A |
| DTC No. | Data List |
|---|---|
| P1E6B73 | Fuel Lid Interlock Switch |
It is suspected that there is a GND short in the fuel lid with motor lock assembly (interlock switch) circuit, or the fuel lid with motor lock assembly (interlock switch) has stuck closed.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After performing repairs, clear the DTCs, perform the following procedure, and then check the data list items "Fuel Lid Interlock SW".
Turn the ignition switch off and press the fuel lid opener switch to open the fuel lid.
Turn the ignition switch to ON.
By referring to the table below, check that the "Fuel Lid Interlock SW" of the data list turns ON or OFF in accordance with the fuel lid operation.
| Fuel lid fully closed | Fuel lid fully open |
|---|---|
| OFF | ON |
Click hereVehicle Exterior>DOOR / HATCH>FUEL LID OPENER MOTOR ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the fuel lid with motor lock assembly (interlock switch) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G70,G14)Location & Routingewd_type=routing;type=c,c;code=G70,G14 Click Connector(G70)Body>Floor Wire / No. 3 Floor Wire>Fuel Lid Lock with Motor Assemblyewd_type=component;type=c;code=G70;pinno=3 Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECUewd_type=component;type=c;code=G14;pinno=5 |
||
| G70-3 (B) - G14-5 (FILK) | Always | Below 1 Ω |
| G70-3 (B) or G14-5 (FILK) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the fuel lid with motor lock assembly (interlock switch) connector.
Reconnect the EV control ECU connector.
OK
NG
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the fuel lid with motor lock assembly (interlock switch) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G70,A14)Location & Routingewd_type=routing;type=c,c;code=G70,A14 Click Connector(G70)Body>Floor Wire / No. 3 Floor Wire>Fuel Lid Lock with Motor Assemblyewd_type=component;type=c;code=G70;pinno=3 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=5 |
||
| G70-3 (B) - A14-5 (FILK) | Always | Below 1 Ω |
| G70-3 (B) or A14-5 (FILK) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the fuel lid with motor lock assembly (interlock switch) connector.
Reconnect the EV control ECU connector.
OK
NG
Pre-procedure1
Disconnect the fuel lid with motor lock assembly (interlock switch) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G70)Location & Routingewd_type=routing;type=c;code=G70 Click Connector(G70)Body>Floor Wire / No. 3 Floor Wire>Fuel Lid Lock with Motor Assemblyewd_type=component;type=c;code=G70;pinno=2 |
||
| G70-2 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the fuel lid with motor lock assembly (interlock switch) connector.
OK
NG