The opening sensor is installed on the air sealing valve to detect the opening angle of the valve as voltage.
This is a non-contact type sensor. As the valve closes, the sensor output voltage decreases and the sensor calculates the opening angle of the valve based on the signal which increases as the valve opens.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1DC711 | Air Sealing Valve Position Sensor Circuit Short to Ground | If the +B voltage is not low when the ignition switch is ON, the output voltage of the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) circuit remains at less than 0.10 V for more than 3 seconds.
(1 trip detection logic) |
·
FC air pressure regulator assembly (air sealing valve (opening angle sensor)) ·
FC control ECU ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| P1DC715 | Air Sealing Valve Position Sensor Circuit Short to Battery or Open | If the +B voltage is not low when the ignition switch is ON, the output voltage of the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) circuit remains at more than 4.80 V for more than 3 seconds.
(1 trip detection logic) |
·
FC air pressure regulator assembly (air sealing valve (opening angle sensor)) ·
FC control ECU ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List (EV)
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List (EV)
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | ○ | ○ | ○ | ○ | ○ | - |
| DTC No. | Data List |
|---|---|
| P1DC711 | Air Sealing Valve Position Sensor Voltage |
| P1DC715 |
If DTCs are found, read the "Air Sealing Valve Position Sensor Voltage" in the Data List on a GTS.
| Air Sealing Valve Position Sensor Voltage | Malfunction |
|---|---|
| Less than 0.10 V | ·
Open in VASP (5 V power supply) circuit ·
Short in ASP circuit to ground ·
Short in ASP circuit to GASP (GND) circuit |
| Higher than 4.80 V | ·
Short in VASP circuit to ASP circuit ·
Open in ASP circuit ·
Open in GASP (GND) circuit ·
Short in VASP circuit to ground |
It is suspected that malfunctions, or open/short circuits have occurred in the air sealing valve (opening angle sensor).
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON and wait for 3 seconds or more.
Pre-procedure1
Disconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B14)Location & Routingewd_type=routing;type=c;code=B14 Click Connector(B14)Engine Compartment>No. 2 Stack Wire>FC Air Pressure Regulator Assembly (Air Shut Valve)ewd_type=component;type=c;code=B14;pinno=2,3,4 |
||
| B14-2 (VASP) - B14-3 (GASP) | Ignition switch ON | 4.75 to 5.25 V |
| B14-4 (ASP) - B14-3 (GASP) | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B1,B14)Location & Routingewd_type=routing;type=c,c;code=B1,B14 Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECUewd_type=component;type=c;code=B1;pinno=99,98,97 Click Connector(B14)Engine Compartment>No. 2 Stack Wire>FC Air Pressure Regulator Assembly (Air Shut Valve)ewd_type=component;type=c;code=B14;pinno=4,3,2 |
||
| B1-99 (ASP) - B14-4 (ASP) | Always | Below 1 Ω |
| B1-98 (GASP) - B14-3 (GASP) | Always | Below 1 Ω |
| B1-97 (VASP) - B14-2 (VASP) | Always | Below 1 Ω |
| B1-99 (ASP) or B14-4 (ASP) - Body ground and other terminals | Always | 10 kΩ or higher |
| B1-97 (VASP) or B14-2 (VASP) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
Reconnect the FC control ECU connector.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Pre-procedure1
Turn the ignition switch to ON and wait for 3 seconds or more.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1DC711 or P1DC715 is output | A |
| DTCs are not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
Disconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
Disconnect the FC air pressure regulator assembly (air pressure regulating valve (opening angle sensor)) connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B14)Location & Routingewd_type=routing;type=c;code=B14 Click Connector(B14)Engine Compartment>No. 2 Stack Wire>FC Air Pressure Regulator Assembly (Air Shut Valve)ewd_type=component;type=c;code=B14;pinno=2,3,4 |
||
| B14-2 (VASP) - B14-3 (GASP) | Ignition switch ON | 4.75 to 5.25 V |
| B14-4 (ASP) - B14-3 (GASP) | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the FC air pressure regulator assembly (air pressure regulating valve (opening angle sensor)) connector.
Reconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
OK
NG
Pre-procedure1
Disconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
Disconnect the FC air by-pass valve assembly (air shunt valve (opening angle sensor)) connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B14)Location & Routingewd_type=routing;type=c;code=B14 Click Connector(B14)Engine Compartment>No. 2 Stack Wire>FC Air Pressure Regulator Assembly (Air Shut Valve)ewd_type=component;type=c;code=B14;pinno=2,3,4 |
||
| B14-2 (VASP) - B14-3 (GASP) | Ignition switch ON | 4.75 to 5.25 V |
| B14-4 (ASP) - B14-3 (GASP) | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the FC air by-pass valve assembly (air shunt valve (opening angle sensor)) connector.
Reconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B1,B14)Location & Routingewd_type=routing;type=c,c;code=B1,B14 Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECUewd_type=component;type=c;code=B1;pinno=99,98,97 Click Connector(B14)Engine Compartment>No. 2 Stack Wire>FC Air Pressure Regulator Assembly (Air Shut Valve)ewd_type=component;type=c;code=B14;pinno=4,3,2 |
||
| B1-99 (ASP) - B14-4 (ASP) | Always | Below 1 Ω |
| B1-98 (GASP) - B14-3 (GASP) | Always | Below 1 Ω |
| B1-97 (VASP) - B14-2 (VASP) | Always | Below 1 Ω |
| B1-99 (ASP) or B14-4 (ASP) - Body ground and other terminals | Always | 10 kΩ or higher |
| B1-97 (VASP) or B14-2 (VASP) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC air pressure regulator assembly (air sealing valve (opening angle sensor)) connector.
Reconnect the FC control ECU connector.
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the FC air pressure regulator assembly (air pressure regulating valve (opening angle sensor)) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B1,B16)Location & Routingewd_type=routing;type=c,c;code=B1,B16 Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECUewd_type=component;type=c;code=B1;pinno=72 Click Connector(B16)Engine Compartment>No. 2 Stack Wire>FC Air Pressure Regulator Assembly (Air Pressure Regulation Valve)ewd_type=component;type=c;code=B16;pinno=2 |
||
| B1-72 (VAVP) - B16-2 (VAVP) | Always | Below 1 Ω |
| B1-72 (VAVP) or B16-2 (VAVP) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC air pressure regulator assembly (air pressure regulating valve (opening angle sensor)) connector.
Reconnect the FC control ECU connector.
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the FC air by-pass valve assembly (air shunt valve (opening angle sensor)) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B1,B15)Location & Routingewd_type=routing;type=c,c;code=B1,B15 Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECUewd_type=component;type=c;code=B1;pinno=118 Click Connector(B15)Engine Compartment>No. 2 Stack Wire>FC Air By-Pass Valve Assemblyewd_type=component;type=c;code=B15;pinno=4 |
||
| B1-118 (VABP) - B15-4 (VABP) | Always | Below 1 Ω |
| B1-118 (VABP) or B15-4 (VABP) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC air by-pass valve assembly (air shunt valve (opening angle sensor)) connector.
Reconnect the FC control ECU connector.
OK
NG