Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2021.08
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0463852 HYBRID CONTROL SYSTEM L

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  PRECAUTION  


PRECAUTIONS FOR INSPECTING HYBRID CONTROL SYSTEM


a.
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV supply battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side.

·

Inspecting the high-voltage system

·

Disconnecting the low voltage connector of the inverter with converter assembly

·

Disconnecting the low voltage connector of the EV supply battery

·

Disconnecting the low voltage connector of the FC converter assembly

·

Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)



b.
A484004

To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side to cut off the high voltage circuit before servicing the vehicle.


c.
A358042

After removing the EV supply battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.

·

The technician performing the work should put the EV supply battery service plug grip in their pocket and carry it with them.

·

Remove the FC converter power outlet cable (inverter with converter assembly) on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.


NOTICE:

After removing the EV supply battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, turning the ignition switch to ON (READY) may cause a malfunction. Do not turn the ignition switch to ON (READY) unless instructed by the repair manual.


HINT:

No removal order is specified for the EV supply battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side.


i.

Remove the EV supply battery service plug grip.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>SERVICE PLUG GRIP>REMOVAL

A478486


ii.

Remove the FC converter power outlet cable (inverter with converter assembly) on FC converter side.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL

A476937N01
1.042,1.479 1.198,1.677 0.156,0.198 10 true 1 2.188,0.365 2.344,0.563 0.156,0.198 10 true 1 1.448,0.156 1.604,0.354 0.156,0.198 10 true 2 1.042,1.688 1.198,1.885 0.156,0.198 10 true A 2.188,0.563 2.344,0.76 0.156,0.198 10 true A 1.438,0.344 1.594,0.542 0.156,0.198 10 true B

1.

Remove the 2 bolts A and bolt B in the order shown in the illustration.

NOTICE:

Removing the bolts in an incorrect order may damage the FC converter and FC converter power outlet cable (inverter with converter assembly).


2.

Disconnect the FC converter power outlet cable.

3.

Protect the openings of the FC converter assembly with protective tape (non-residue type) to prevent the entry of foreign matter or water.

4.

Use the "CAUTION: HIGH VOLTAGE DO NOT TOUCH" sign to notify other technicians that the high-voltage system is being inspected and/or repaired.

NOTICE:

Be careful not to touch the terminal before or during attaching the display label.





d.
A484005C01
1.667,0.74 2.115,0.427 true 2.188,0.385 2.448,0.552 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the EV supply battery service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and FC converter assembly.



e.

Check the voltage at the terminals in the inspection point in the inverter with converter assembly.

CAUTION:

Be sure to wear insulated gloves.


i.
A483129C01
0.177,0.146 0.448,0.385 0.271,0.24 12 true *A 0.229,2.552 0.479,2.792 0.25,0.24 12 true *B
*A for LHD
*B for RHD


Remove the connector cover assembly from the inverter with converter assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




ii.
A483131C01
0.229,0.115 0.5,0.354 0.271,0.24 12 true *A 0.208,2.5 0.458,2.74 0.25,0.24 12 true *B
*A for LHD
*B for RHD


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
Inspection point At least 10 minutes after removing the service plug grip 0 V


HINT:

Set the tester to DC750 V or more to measure the voltage.



iii.

Reinstall the connector cover assembly.



f.
A358019

When turning the ignition switch to ON during an inspection, do not press the ignition switch with the brake pedal depressed.

CAUTION:

Pressing the ignition switch with the brake pedal depressed causes the system to enter the READY-on state. This is very dangerous because high voltage may be applied to the inspection area.



g.

Turn the ignition switch off, wear insulated gloves, and disconnect the cable from the negative (-) terminal of the auxiliary battery before touching any of the orange-colored wires of the high-voltage system.

NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART





h.

Turn the ignition switch off before performing any resistance checks.


i.

Turn the ignition switch off before disconnecting or reconnecting any connectors.


j.

When performing work involving high-voltage wires, use either a tool wrapped with vinyl insulation tape or an insulated tool.


k.

When high-voltage connectors are removed, wrap the connectors with insulation tape to prevent them from contacting foreign matter.


l.

Connect the FC converter power outlet cable to the FC converter.

A479311N01
2.281,0.125 2.698,0.469 0.417,0.344 18 true i, ii 3.198,0.063 3.354,0.26 0.156,0.198 10 true 1 4.021,0.385 4.177,0.583 0.156,0.198 10 true A 2.875,1.271 3.031,1.469 0.156,0.198 10 true 2 3.115,0.281 3.271,0.479 0.156,0.198 10 true B 3.99,0.156 4.146,0.354 0.156,0.198 10 true 2 2.885,1.479 3.042,1.677 0.156,0.198 10 true A

NOTICE:

Installing the bolts in an incorrect order may damage the FC converter and FC converter power outlet cable (inverter with converter assembly).


i.

Tighten the 2 bolts (A) and bolt (B) in the order shown in the illustration.

Torque:
8.0 N・m (82 kgf・cm, )



m.

Reinstall the EV supply battery service plug grip.

A476992

NOTICE:
·

Before connecting the EV supply battery service plug grip, check that no components or tools have been left behind, and check that high voltage terminals are tightened and connectors are connected.

·

After lowering the EV supply battery service plug grip 90°, securely slide it until a "click" sound is heard.





NOTICE FOR HYBRID CONTROL SYSTEM ACTIVATION


a.

When the warning light is illuminated, or the auxiliary battery has been disconnected and reconnected, attempting to turn the ignition switch to ON (READY) may not start the system (the system may not enter the READY-on state) on the first attempt. If so, turn the ignition switch off and reattempt to start the EV system.

NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART






NOTICE FOR ANTIFREEZE CONTROL


a.

When the vehicle is parked with the ignition switch off, if the EV control ECU judges that the FC stack temperature will go below 0°C (32°F), it activates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds and drains water from the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work (If the auxiliary battery voltage is needed to conduct inspection, warm up the FC system beforehand).



PRECAUTIONS FOR DISCONNECTING AMD TERMINAL


HINT:

The AMD terminal is connected to the positive terminal of the auxiliary battery. To prevent damage when the AMD terminal is being disconnected, use the following procedure.


a.
A483133C01
0.594,0.375 0.792,0.531 0.198,0.156 10 true *1 2.615,1.198 2.823,1.354 0.208,0.156 10 true *2 2.885,3.052 3.104,3.208 0.219,0.156 10 true *1 0.417,3.344 0.625,3.5 0.208,0.156 10 true *2 0.177,0.146 0.427,0.344 0.25,0.198 12 true *A 0.219,2.531 0.469,2.729 0.25,0.198 12 true *B
*A for LHD
*B for RHD
*1 AMD Terminal (Inverter with Converter Assembly Side)
*2 AMD Terminal (Fusible Link Block Assembly Side)


Be sure to disconnect the cable from the negative (-) auxiliary battery terminal before disconnecting the AMD terminal from the fusible link block assembly.

NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART





b.

After disconnecting the AMD terminal, wrap the terminal with insulation tape.


c.

Be sure to reconnect the AMD terminal to the fusible link block assembly before reconnecting the cable to the negative (-) terminal of the auxiliary battery.

NOTICE:

A short circuit to ground may occur if the AMD terminal is disconnected before the cable is disconnected from the negative (-) auxiliary battery terminal. If a short circuit to ground occurs, a fusible link or fuse may break.




DISPOSING OF EV SUPPLY BATTERY ASSEMBLY AND EV SUPPLY STACK SUB-ASSEMBLY


a.

When disposing of EV supply battery assemblies and EV supply stack sub-assemblies, make sure to return them through an authorized collection agent who is capable of handling them safely. If they are returned via the manufacturer specified route, they will be returned properly and in a safe manner by an authorized collection agent.

CAUTION:
·

Before returning the EV supply battery assembly, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION

·

Before returning the EV supply stack sub-assembly, make sure to perform a recovery inspection

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>RECOVERY INSPECTION

·
A358020

After removing the EV supply battery assembly or the EV supply stack sub-assembly, keep it away from water. Exposure to water may cause the EV supply battery assembly or the EV supply stack sub-assembly to produce heat, resulting in a fire.

·
A358021C32
0.604,4.135 0.917,4.333 0.313,0.198 10 false *a 2.719,4.135 3.031,4.333 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


Accidents such as electric shock may result if the EV supply battery assembly or the EV supply stack sub-assembly is disposed of improperly or abandoned.

Therefore, make sure to return EV supply battery assembly and all EV supply stack sub-assemblies through an authorized collection agent.

·

To reduce the risk of fire, EV supply battery assembly or EV supply stack sub-assemblies must not be stored in an area where they will be exposed to fire or high temperatures.

·

If the temperature of the EV supply battery assembly and EV supply stack sub-assembly is high, leave the vehicle until the temperature drops.

·

Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly or EV supply stack sub-assemblies with insulating tape after removing them.

If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.





PRECAUTIONS WHEN REPLACING EV CONTROL ECU


NOTICE:
·

Before replacing the EV control ECU, refer to Service Bulletin.

·

When the EV control ECU is replaced, update the ECU security key.

Click hereGeneral>SETUP>WHEN REPLACING OR REMOVING/INSTALLING PARTS>UPDATE ECU SECURITY KEY




PRECAUTION WHEN REPLACING BATTERY ECU ASSEMBLY AND EV CONTROL ECU


EV battery learning values are stored in the battery ECU assembly and EV control ECU to display "Maintenance Required for Traction Battery at Your Dealer" on the multi-information display. When either of these ECUs is replaced, the new ECU receives the EV battery learning value data from the other ECU and updates the information.

NOTICE:
·

Do not replace the battery ECU assembly and EV control ECU at the same time as it clears the EV battery learning values. However, if it is necessary to replace both ECUs at the same time, replace them by following the procedure below.

·

Do not replace the battery ECU assembly or EV control ECU with used ones from other vehicles.



a.

Procedure when replacing both battery ECU assembly and EV control ECU:

i.

Disconnect the cable from the negative (-) auxiliary battery terminal.


ii.

Replace either of the ECUs.


iii.

Connect the cable to the negative (-) auxiliary battery terminal.


iv.

Turn the ignition switch to ON (READY) and wait for 5 minutes or more.


v.

Turn the ignition switch off and disconnect the cable from the negative (-) auxiliary battery terminal.


vi.

Replace the other ECU.


vii.

Connect the cable to the negative (-) auxiliary battery terminal.


viii.

Check that the ignition switch can be turned to ON (READY).

HINT:

If the battery ECU assembly and EV control ECU are replaced at the same time without following the above procedure, replace either of the ECUs with its original one and then replace it again by following the above procedure. If the correct procedure is not followed, perform the procedure again from the beginning.