| *1 | FC COOLING WATER PUMP INVERTER ASSEMBLY | *2 | FC HYDROGEN PUMP INVERTER ASSEMBLY |
|
N*m (kgf*cm, ft.*lbf): Specified torque | ● | Non-reusable part |
|
THERMAL GREASE X-23-7887-4 | - | - |
| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 4 | FC CONVERTER ASSEMBLY | G9A10 | - | - | - |
1.INSTALL FC COOLING WATER PUMP INVERTER ASSEMBLY AND FC HYDROGEN PUMP INVERTER ASSEMBLY
| *a | Apply grease here | *b | Do not apply grease here |
|
Bolt A |
|
Bolt B |
|
THERMAL GREASE X-23-7887-4 | - | - |
Clean grease from the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly installation areas on the FC converter case sub-assembly.
Clean and degrease the installation surface using non-residue solvent and brake cleaner.
Apply Toyota genuine thermal grease X-23-7887-4 to a new FC cooling water pump inverter assembly and new FC hydrogen pump inverter assembly, and set them to the FC converter case sub-assembly.
Do not allow grease on the 4 bus bar locations and 6 installation seat locations on the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly.
Do not allow heat dissipating grease on other parts, etc. before seating the FC converter case sub-assembly.
Do not reuse the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly.
Temporarily install the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly with the 10 bolts.
| Item | Length |
|---|---|
| A | 16 mm (0.630 in.) |
| B | 12 mm (0.472 in.) |
Tighten the 10 bolts in the order shown in the illustration.
G9A10
4.INSTALL FC CONVERTER ASSEMBLY