The FC system introduces air into the FC stack using the air sealing valve at the entrance of the FC stack and regulates the pressure using the air pressure regulating valve at the exit of the FC stack, in order to maintain the power generation performance of the FC stack.
When the system is stopped, it closes and seals the air sealing valve at the FC stack entrance and the air pressure regulating valve at the exit.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1DC618 | Air Sealing Valve Circuit Current Below Threshold | All of the following conditions are met, and there is an open circuit in the air sealing valve (motor) circuit for 1 second or more continuously when an open circuit is confirmed during the initial check.
·
No +B low voltage when ignition switch is ON ·
Valve drive power source (+BP3) is 9 V or higher (1 trip detection logic) |
·
FC air pressure regulator assembly (air sealing valve (motor)) ·
FC control ECU ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| P1DC619 | Air Sealing Valve Circuit Current Above Threshold | All of the following conditions are met, and there is a short to ground in the air sealing valve (motor) circuit for 1 second or more continuously when there is an operation standby condition during the initial check.
·
No +B low voltage when ignition switch is ON ·
Valve drive power source (+BP3) is 9 V or higher (1 trip detection logic) |
·
FC air pressure regulator assembly (air sealing valve (motor)) ·
FC control ECU ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List (EV)
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List (EV)
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | ○ | - | - | - | - | - |
| DTC No. | Data List |
|---|---|
| P1DC618 | ·
Air Sealing Valve Motor Duty ·
Air Sealing Valve Position Sensor Voltage |
| P1DC619 |
It is suspected that the air shunt valve or FC control ECU has a malfunction, or open or short circuit.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Put the state in park (P) and turn the ignition switch to ON (READY), and wait until the "FC Work Mode" in the Data List switches over from Startup to Working.
Click hereEngine / Hybrid System>INTAKE / EXHAUST>AIR CONTROL VALVE>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the FC air pressure regulator assembly (air sealing valve (motor)) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A48,B14)Location & Routingewd_type=routing;type=c,c;code=A48,B14 Click Connector(A48)Engine Compartment>Front Compartment Main Wire / No. 3 Front Compartment Wire / No. 4 Front Compartment Wire>FC Control ECUewd_type=component;type=c;code=A48;pinno=3,22 Click Connector(B14)Engine Compartment>No. 2 Stack Wire>FC Air Pressure Regulator Assembly (Air Shut Valve)ewd_type=component;type=c;code=B14;pinno=6,5 |
||
| A48-3 (ASV1) - B14-6 (ASV1) | Always | Below 1 Ω |
| A48-22 (ASV2) - B14-5 (ASV2) | Always | Below 1 Ω |
| A48-3 (ASV1) or B14-6 (ASV1) - Body ground and other terminals | Always | 10 kΩ or higher |
| A48-22 (ASV2) or B14-5 (ASV2) - Body ground and other terminals | Always | 10 kΩ or higher |
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A48)Location & Routingewd_type=routing;type=c;code=A48 Click Connector(A48)Engine Compartment>Front Compartment Main Wire / No. 3 Front Compartment Wire / No. 4 Front Compartment Wire>FC Control ECUewd_type=component;type=c;code=A48;pinno=3,22 |
||
| A48-3 (ASV1) or A48-22 (ASV2) - Body ground | Ignition switch ON | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the FC air pressure regulator assembly (air sealing valve (motor)) connector.
Reconnect the FC control ECU connector.
OK
NG