The FC control ECU regulates the FC cooling water temperature control valve so as to maintain the FC stack coolant temperature at a specified level. In order to obtain an appropriate FC stack coolant temperature for the FC stack power generation, the FC control ECU switches the direction of the coolant passage to the bypass side if the FC stack coolant temperature is below a target temperature, or to the radiator if the temperature is above a target.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1DD514 | Radiator Rotary Valve Circuit 1 Circuit Short to Ground or Open | No +B low voltage when ignition switch is ON, output is off at all the 4 terminals of the FC cooling water temperature control valve step motor, or the WRA1 terminal is judged as abnormal for 1 second or more while the motor is running.
(1 trip detection logic) |
·
FC cooling water temperature control valve ·
FC control ECU ·
FC-B relay ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| P1EFD14 | Radiator Rotary Valve Circuit 2 Circuit Short to Ground or Open | No +B low voltage when ignition switch is ON, output is off at all the 4 terminals of the FC cooling water temperature control valve step motor, or the WRA2 terminal is judged as abnormal for 1 second or more while the motor is running.
(1 trip detection logic) |
·
FC cooling water temperature control valve ·
FC control ECU ·
FC-B relay ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| P1EFE14 | Radiator Rotary Valve Circuit 3 Circuit Short to Ground or Open | No +B low voltage when ignition switch is ON, output is off at all the 4 terminals of the FC cooling water temperature control valve step motor, or the WRB1 terminal is judged as abnormal for 1 second or more while the motor is running.
(1 trip detection logic) |
·
FC cooling water temperature control valve ·
FC control ECU ·
FC-B relay ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| P1EFF14 | Radiator Rotary Valve Circuit 4 Circuit Short to Ground or Open | No +B low voltage when ignition switch is ON, output is off at all the 4 terminals of the FC cooling water temperature control valve step motor, or the WRB2 terminal is judged as abnormal for 1 second or more while the motor is running.
(1 trip detection logic) |
·
FC cooling water temperature control valve ·
FC control ECU ·
FC-B relay ·
Wire harness or connector |
Master Warning: Comes on | FC | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | ○ | ○ | ○ | ○ | ○ | - |
| DTC No. | Data List |
|---|---|
| P1DD514 | Radiator Rotary Valve Position |
| P1EFD14 | |
| P1EFE14 | |
| P1EFF14 |
| DTC No. | Active Test |
|---|---|
| P1DD514 | Control the Radiator Rotary Valve |
| P1EFD14 | |
| P1EFE14 | |
| P1EFF14 |
Inspect the fuses of circuits related to this system before performing the following procedure.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON and wait for 1 second or more.
Pre-procedure1
Disconnect the FC cooling water temperature control valve connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B17)Location & Routingewd_type=routing;type=c;code=B17 Click Connector(B17)Engine Compartment>No. 2 Stack Wire>FC Cooling Water Temperature Control Valveewd_type=component;type=c;code=B17;pinno=2,5 |
||
| B17-2 (+B1) - Body ground | Ignition switch ON | 11 to 14 V |
| B17-5 (+B2) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the FC cooling water temperature control valve connector.
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Disconnect the FC cooling water temperature control valve connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A48,B17)Location & Routingewd_type=routing;type=c,c;code=A48,B17 Click Connector(A48)Engine Compartment>Front Compartment Main Wire / No. 3 Front Compartment Wire / No. 4 Front Compartment Wire>FC Control ECUewd_type=component;type=c;code=A48;pinno=8,7,5,4 Click Connector(B17)Engine Compartment>No. 2 Stack Wire>FC Cooling Water Temperature Control Valveewd_type=component;type=c;code=B17;pinno=3,1,6,4 |
||
| A48-8 (WRA1) - B17-3 (WRA1) | Always | Below 1 Ω |
| A48-7 (WRA2) - B17-1 (WRA2) | Always | Below 1 Ω |
| A48-5 (WRB1) - B17-6 (WRB1) | Always | Below 1 Ω |
| A48-4 (WRB2) - B17-4 (WRB2) | Always | Below 1 Ω |
| A48-8 (WRA1) or B17-3 (WRA1) - Body ground and other terminals | Always | 10 kΩ or higher |
| A48-7 (WRA2) or B17-1 (WRA2) - Body ground and other terminals | Always | 10 kΩ or higher |
| A48-5 (WRB1) or B17-6 (WRB1) - Body ground and other terminals | Always | 10 kΩ or higher |
| A48-4 (WRB2) or B17-4 (WRB2) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC cooling water temperature control valve connector.
Reconnect the FC control ECU connector.
OK
NG
OK
NG
Pre-procedure1
Disconnect the FC control ECU connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B1)Location & Routingewd_type=routing;type=c;code=B1 Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECUewd_type=component;type=c;code=B1;pinno=104 |
||
| B1-104 (E1) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC control ECU connector.
OK
NG
Pre-procedure1
Disconnect the FC cooling water temperature control valve connector.
Remove the FC-B relay from the No. 1 front compartment relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B17)Location & Routingewd_type=routing;type=c;code=B17 Click Connector(B17)Engine Compartment>No. 2 Stack Wire>FC Cooling Water Temperature Control Valveewd_type=component;type=c;code=B17;pinno=2,5 |
||
| B17-2 (+B1) - 5 (FC-B relay holder) | Always | Below 1 Ω |
| B17-5 (+B2) - 5 (FC-B relay holder) | Always | Below 1 Ω |
| B17-2 (+B1), B17-5 (+B2) or 5 (FC-B relay holder) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reinstall the FC-B relay.
Reconnect the FC cooling water temperature control valve connector.
OK
NG