N*m (kgf*cm, ft.*lbf): Specified torque | - | - |
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the FC cooling water temperature control valve removal/installation are shown below.
When the cable is disconnected/reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Learning completes when vehicle is operated normally
| Effect/Inoperative Function When Necessary Procedures are not Performed | Necessary Procedures | Link |
|---|---|---|
| Air conditioning system | After the ignition switch is turned to ON, the servo motor and expansion valve standard position is recognized. | - |
2. CAUTIONS FOR COOLANT (FC STACK COOLANT)
3. PRECAUTION
16A40
4.REMOVE FC COOLING WATER ION EXCHANGER ASSEMBLY
G3834
5.REMOVE SERVICE PLUG GRIP
G9200A
10.DISCONNECT FC CONVERTER POWER OUTLET CABLE (INVERTER WITH CONVERTER ASSEMBLY)
|
|
| *A | for LHD | *B | for RHD |
G9A25
11.REMOVE FC CONVERTER POWER OUTLET BRACKET
82662B
12.REMOVE NO. 2 RELAY BLOCK COVER
82121F
13.DISCONNECT STACK WIRE
88689F
14.REMOVE NO. 2 COOLER BRACKET
16579A
15.REMOVE NO. 9 FC RADIATOR HOSE
Slide the clip and remove the No. 9 FC radiator hose from the FC cooling water temperature sensor control valve.
To prevent contamination by foreign matter, cover the connecting portions of the No. 9 FC radiator hose and FC cooling water temperature control valve with plastic bags.
16577D
16.DISCONNECT NO. 7 FC RADIATOR HOSE
Slide the clip and disconnect the No. 7 FC radiator hose from the FC cooling water temperature sensor control valve.
To prevent contamination by foreign matter, cover the connecting portions of the No. 7 FC radiator hose and FC cooling water temperature control valve with plastic bags.
16A31
17.REMOVE FC COOLING WATER TEMPERATURE CONTROL VALVE
|
|
Remove the 3 bolts and disconnect the connector.
To prevent contamination by foreign matter, cover the connecting portions of the FC cooling water temperature control valve with plastic bags.
Slide the clip and remove the No. 6 FC radiator hose from the FC cooling water temperature sensor control valve.