The cause of the malfunction may be the low-voltage circuit.
Check whether there is an open circuit in the inverter +B low-voltage power source system or a problem in the communication between the EV control ECU and inverter.
| Area | Inspection |
|---|---|
| Inverter +B low-voltage power source system check | Check for inverter overcurrent malfunction. |
| Communication malfunction between EV control ECU and MG-ECU inside inverter with converter assembly | Check for inverter overcurrent malfunction due to communication malfunction. |
| Check for short to ground in inverter +B low-voltage power source system | - |
This step is referenced from the procedures for each DTC.
If the inspection results below are normal, perform the next procedure for the referenced DTC.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the electric vehicle charger assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
| *1 | Luggage Room Relay Block |
| *2 | IGCT NO. 4 Fuse |
Remove the IGCT NO. 4 fuse from the Luggage Room Relay Block.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 4 fuse terminal | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the IGCT NO. 4 fuse.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-30 (GND1) - Body ground | Ignition switch off | Below 1 Ω |
| A19-31 (GND2) - Body ground | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-30 (GND1) - Body ground | Ignition switch off | Below 1 Ω |
| A18-31 (GND2) - Body ground | Ignition switch off | Below 1 Ω |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-10 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| A19-11 (+B2) - Body ground | Ignition switch ON | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-10 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| A18-11 (+B2) - Body ground | Ignition switch ON | 11 to 14 V |
Turning the ignition switch to ON (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Disconnect the A16 EV control ECU connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
*b | Rear view of wire harness connector
(to EV Control ECU) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19,A16)Location & Routingewd_type=routing;type=c,c;code=A19,A16 Click Connector(A16)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A16;pinno=10,11,16,17,14,15,12,13 |
||
| A19-23 (HTM+) - A16-10 (HTM+) | Ignition switch off | Below 1 Ω |
| A19-22 (HTM-) - A16-11 (HTM-) | Ignition switch off | Below 1 Ω |
| A19-3 (MTH+) - A16-16 (MTH+) | Ignition switch off | Below 1 Ω |
| A19-2 (MTH-) - A16-17 (MTH-) | Ignition switch off | Below 1 Ω |
| A19-34 (REQ+) - A16-14(REQ+) | Ignition switch off | Below 1 Ω |
| A19-33 (REQ-) - A16-15 (REQ-) | Ignition switch off | Below 1 Ω |
| A19-14 (CLK+) - A16-12 (CLK+) | Ignition switch off | Below 1 Ω |
| A19-13 (CLK-) - A16-13 (CLK-) | Ignition switch off | Below 1 Ω |
| A19-23 (HTM+) or A16-10 (HTM+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A19-22 (HTM-) or A16-11 (HTM-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A19-3 (MTH+) or A16-16 (MTH+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A19-2 (MTH-) or A16-17 (MTH-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A19-34 (REQ+) or A16-14(REQ+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A19-33 (REQ-) or A16-15 (REQ-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A19-14 (CLK+) or A16-12 (CLK+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A19-13 (CLK-) or A16-13 (CLK-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18,A16)Location & Routingewd_type=routing;type=c,c;code=A18,A16 Click Connector(A16)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A16;pinno=10,11,16,17,14,15,12,13 |
||
| A18-23 (HTM+) - A16-10 (HTM+) | Ignition switch off | Below 1 Ω |
| A18-22 (HTM-) - A16-11 (HTM-) | Ignition switch off | Below 1 Ω |
| A18-3 (MTH+) - A16-16 (MTH+) | Ignition switch off | Below 1 Ω |
| A18-2 (MTH-) - A16-17 (MTH-) | Ignition switch off | Below 1 Ω |
| A18-34 (REQ+) - A16-14(REQ+) | Ignition switch off | Below 1 Ω |
| A18-33 (REQ-) - A16-15 (REQ-) | Ignition switch off | Below 1 Ω |
| A18-14 (CLK+) - A16-12 (CLK+) | Ignition switch off | Below 1 Ω |
| A18-13 (CLK-) - A16-13 (CLK-) | Ignition switch off | Below 1 Ω |
| A18-23 (HTM+) or A16-10 (HTM+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A18-22 (HTM-) or A16-11 (HTM-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A18-3 (MTH+) or A16-16 (MTH+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A18-2 (MTH-) or A16-17 (MTH-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A18-34 (REQ+) or A16-14(REQ+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A18-33 (REQ-) or A16-15 (REQ-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A18-14 (CLK+) or A16-12 (CLK+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A18-13 (CLK-) or A16-13 (CLK-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19,A16)Location & Routingewd_type=routing;type=c,c;code=A19,A16 Click Connector(A16)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A16;pinno=10,11,16,17,14,15,12,13 |
||
| A19-23 (HTM+) or A16-10 (HTM+) - Body ground | Ignition switch ON | Below 1 V |
| A19-22 (HTM-) or A16-11 (HTM-) - Body ground | Ignition switch ON | Below 1 V |
| A19-3 (MTH+) or A16-16 (MTH+) - Body ground | Ignition switch ON | Below 1 V |
| A19-2 (MTH-) or A16-17 (MTH-) - Body ground | Ignition switch ON | Below 1 V |
| A19-34 (REQ+) or A16-14(REQ+) - Body ground | Ignition switch ON | Below 1 V |
| A19-33 (REQ-) or A16-15 (REQ-) - Body ground | Ignition switch ON | Below 1 V |
| A19-14 (CLK+) or A16-12 (CLK+) - Body ground | Ignition switch ON | Below 1 V |
| A19-13 (CLK-) or A16-13 (CLK-) - Body ground | Ignition switch ON | Below 1 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18,A16)Location & Routingewd_type=routing;type=c,c;code=A18,A16 Click Connector(A16)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A16;pinno=10,11,16,17,14,15,12,13 |
||
| A18-23 (HTM+) or A16-10 (HTM+) - Body ground | Ignition switch ON | Below 1 V |
| A18-22 (HTM-) or A16-11 (HTM-) - Body ground | Ignition switch ON | Below 1 V |
| A18-3 (MTH+) or A16-16 (MTH+) - Body ground | Ignition switch ON | Below 1 V |
| A18-2 (MTH-) or A16-17 (MTH-) - Body ground | Ignition switch ON | Below 1 V |
| A18-34 (REQ+) or A16-14(REQ+) - Body ground | Ignition switch ON | Below 1 V |
| A18-33 (REQ-) or A16-15 (REQ-) - Body ground | Ignition switch ON | Below 1 V |
| A18-14 (CLK+) or A16-12 (CLK+) - Body ground | Ignition switch ON | Below 1 V |
| A18-13 (CLK-) or A16-13 (CLK-) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the EV control ECU and inverter with converter assembly connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A16 EV control ECU connector.
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
Pre-procedure1
Disconnect the A16 EV control ECU connector.
Procedure1
| *a | Component without harness connected
(EV Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A16)Location & Routingewd_type=routing;type=c;code=A16 Click Connector(A16)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A16;pinno=10,11,16,17,14,15,12,13 |
||
| A16-10 (HTM+) - A16-11 (HTM-) | Ignition switch off | 80 to 170 Ω |
| A16-16 (MTH+) - A16-17 (MTH-) | Ignition switch off | 80 to 170 Ω |
| A16-14 (REQ+) - A16-15 (REQ-) | Ignition switch off | 80 to 170 Ω |
| A16-12 (CLK+) - A16-13 (CLK-) | Ignition switch off | 80 to 170 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A16 EV control ECU connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-10 (+B) - Body ground | Ignition switch off | 10 kΩ or higher |
| A19-11 (+B2) - Body ground | Ignition switch off | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-10 (+B) - Body ground | Ignition switch off | 10 kΩ or higher |
| A18-11 (+B2) - Body ground | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT