Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › from 2021.08
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0453477 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P1AFC00  System Voltage (AM) Circuit Voltage Below Threshold  


DESCRIPTION

The battery ECU assembly monitors its internal operation and will store a DTC when it detects an internal malfunction.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1AFC00 System Voltage (AM) Circuit Voltage Below Threshold The battery ECU assembly shutdown memory procedure did not complete normally in consecutive 40 trips.
(1 trip detection logic)
·

Wire harness or connector

·

Battery ECU assembly

·

Fuse


Master Warning:
Comes on
EV Battery A

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 10 minutes or more.

3.

Turn the ignition switch to ON and wait for 11 seconds or more. *1

4.

Turn the ignition switch off and wait for 30 seconds or more. *2

5.

Perform the procedures *1 and *2 41 times or more.

6.

Enter the following menus: Powertrain / EV Battery / Utility / All Readiness.

7.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




WIRING DIAGRAM

Refer to the wiring diagram for DTC P056014.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P056014

CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.

Make sure to remove the service plug grip first.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the EV supply battery assembly

-

Disconnecting the low voltage connector of the FC converter assembly

-

Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)


·
A484004

To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.

-

The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.

-

Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.


·
A484005C01
1.667,0.74 2.115,0.427 true 2.188,0.385 2.448,0.552 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.

If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.



NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART


·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



PROCEDURE

1.CHECK FUSE (LUG-B NO. 1)

OK

2.CHECK HARNESS AND CONNECTOR (LUG-B NO. 1 FUSE - BATTERY TERMINAL)

NG

REPLACE FUSE (LUG-B NO. 1)

2.CHECK HARNESS AND CONNECTOR (LUG-B NO. 1 FUSE - BATTERY TERMINAL)

OK

3.CHECK CONNECTOR CONNECTION CONDITION (NO. 2 EV BATTERY PACK WIRE CONNECTOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (LUG-B NO. 1 FUSE - BATTERY TERMINAL)

3.CHECK CONNECTOR CONNECTION CONDITION (NO. 2 EV BATTERY PACK WIRE CONNECTOR)

OK

4.CHECK HARNESS AND CONNECTOR (AM VOLTAGE)

NG

CONNECT SECURELY

4.CHECK HARNESS AND CONNECTOR (AM VOLTAGE)

OK

5.CHECK CONNECTOR CONNECTION CONDITION (BATTERY ECU ASSEMBLY CONNECTOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (NO. 2 EV BATTERY PACK WIRE CONNECTOR - BATTERY TERMINAL)

5.CHECK CONNECTOR CONNECTION CONDITION (BATTERY ECU ASSEMBLY CONNECTOR)

OK

6.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - NO. 2 EV BATTERY PACK WIRE CONNECTOR)

NG

CONNECT SECURELY

6.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - NO. 2 EV BATTERY PACK WIRE CONNECTOR)

OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY ECU ASSEMBLY - NO. 2 EV BATTERY PACK WIRE CONNECTOR)