DTC B1800/51 Short in Driver Side Squib Circuit |
DTC B1801/51 Open in Driver Side Squib Circuit |
DTC B1802/51 Short to GND in Driver Side Squib Circuit |
DTC B1803/51 Short to B+ in Driver Side Squib Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1800/51 | Center airbag sensor receives a line short signal 5 times from the driver side squib circuit during primary check. |
|
| B1801/51 | Center airbag sensor receives an open signal from the driver side squib circuit for 2 seconds. |
|
| B1802/51 | Center airbag sensor receives a short to ground signal from the driver side squib circuit for 0.5 seconds. |
|
| B1803/51 | Center airbag sensor receives a short to B+ signal from the driver side squib circuit for 0.5 seconds. |
|

| 1.CHECK STEERING PAD (DRIVER SIDE SQUIB) |
![]() |
Turn the power switch OFF.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connectors from the steering pad.
Connect SST (resistance 2.1 Ω) to connector E (orange connector).
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the power switch ON (IG), and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the power switch OFF.
Turn the power switch ON (IG), and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| NG | |
| 2.CHECK CONNECTOR |
Turn the power switch OFF.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from the spiral cable.
Check that the spiral cable connectors (on the steering pad side) are not damaged.
|
| ||||
| OK | |
| 3.CHECK DRIVER SIDE SQUIB CIRCUIT |
![]() |
Disconnect the connectors from the center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the power switch ON (IG).
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| D+ - Body ground | Below 1 V |
| D- - Body ground | Below 1 V |
Turn the power switch OFF.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| D+ - D- | Below 1 Ω |
| D+ - Body ground | 1 MΩ or higher |
| D- - Body ground | 1 MΩ or higher |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| D+ - D- | 1 MΩ or higher |
|
| ||||
| NG | |
| 4.CHECK INSTRUMENT PANEL WIRE |
![]() |
Restore the released activation prevention mechanism of connector B to its original position.
Disconnect the instrument panel wire connector from the spiral cable.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the power switch ON (IG).
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| A22-1 (D+) - Body ground | Below 1 V |
| A22-2 (D-) - Body ground | Below 1 V |
Turn the power switch OFF.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| A22-1 (D+) - A22-2 (D-) | Below 1 Ω |
| A22-1 (D+) - Body ground | 1 MΩ or higher |
| A22-2 (D-) - Body ground | 1 MΩ or higher |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| A22-1 (D+) - A22-2 (D-) | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||