Home › RESTRAINTS › SUPPLEMENTAL RESTRAINT SYSTEM › AIRBAG SYSTEM

DTC    B1835/58    Short in Front Passenger Side Curtain Shield Squib Circuit

DTC    B1836/58    Open in Front Passenger Side Curtain Shield Squib Circuit

DTC    B1837/58    Short to GND in Front Passenger Side Curtain Shield Squib Circuit

DTC    B1838/58    Short to B+ in Front Passenger Side Curtain Shield Squib Circuit

for Preparation Click here


DESCRIPTION

The front passenger side curtain shield squib circuit consists of the center airbag sensor and the curtain shield airbag RH.
The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are recorded when a malfunction is detected in the front passenger side curtain shield squib circuit.

DTC No.
DTC Detection Condition
Trouble Area
B1835/58
Center airbag sensor receives a line short circuit signal 5 times from the front passenger side curtain shield squib circuit during primary check.
  1. Floor wire No. 2
  2. Curtain shield airbag RH (Front passenger side curtain shield squib)
  3. Center airbag sensor
B1836/58
Center airbag sensor receives an open signal from the front passenger side curtain shield squib circuit for 2 seconds.
  1. Floor wire No. 2
  2. Curtain shield airbag RH (Front passenger side curtain shield squib)
  3. Center airbag sensor
B1837/58
Center airbag sensor receives a short to ground signal from the front passenger side curtain shield squib circuit for 0.5 seconds.
  1. Floor wire No. 2
  2. Curtain shield airbag RH (Front passenger side curtain shield squib)
  3. Center airbag sensor
B1838/58
Center airbag sensor receives a short to B+ signal from the front passenger side curtain shield squib circuit for 0.5 seconds.
  1. Floor wire No. 2
  2. Curtain shield airbag RH (Front passenger side curtain shield squib)
  3. Center airbag sensor

WIRING DIAGRAM


H101119E18


INSPECTION PROCEDURE

HINT:
  1. Perform the simulation method by selecting the "CHECK MODE" (signal check) with the Techstream (Click here).
  2. After selecting the "CHECK MODE" (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on various types of roads (Click here).

1.CHECK CURTAIN SHIELD AIRBAG ASSEMBLY RH (FRONT PASSENGER SIDE CURTAIN SHIELD SQUIB)
C114827E05
  1. Turn the power switch OFF.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect the connectors from the curtain shield airbag RH.

  1. Connect SST (resistance 2.1 Ω) to connector C.

    CAUTION:
    Never connect SST to the curtain shield airbag RH (front passenger side curtain shield squib) for measurement, as this may lead to a serious injury due to airbag deployment.

    NOTICE:
    1. Do not forcibly insert SST into the terminals of the connector when connecting.
    2. Insert SST straight into the terminals of the connector.

SST
09843-18061  
  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the power switch ON (IG), and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the power switch OFF.

  1. Turn the power switch ON (IG), and wait for at least 60 seconds.

  1. Check the DTCs (Click here).

    OK:
    DTC B1835, B1836, B1837, B1838 or 58 is not output.

    HINT:
    DTCs other than DTC B1835, B1836, B1837, B1838 or 58 may be output at this time, but they are not related to this check.



OK
REPLACE CURTAIN SHIELD AIRBAG ASSEMBLY RH
NG


2.CHECK CONNECTOR
  1. Turn the power switch OFF.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect the SST from connector C.

  1. Check that the floor wire No. 2 connector (on the curtain shield airbag RH side) are not damaged.

    OK:
    Lock button is not disengaged, and claw of lock is not deformed or damaged.



NG
REPAIR OR REPLACE FLOOR WIRE NO. 2
OK


3.CHECK FLOOR WIRE NO. 2 (FRONT PASSENGER SIDE CURTAIN SHIELD SQUIB CIRCUIT)
C111666E34
  1. Disconnect the connectors from the center airbag sensor.

  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the power switch ON (IG).

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    C18-1 (IGR+) - Body ground
    Below 1 V
    C18-2 (IGR-) - Body ground
    Below 1 V

  1. Turn the power switch OFF.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Tester Connection
    Specified Condition
    C18-1 (IGR+) - C18-2 (IGR-)
    Below 1 Ω
    C18-1 (IGR+) - Body ground
    1 MΩ or higher
    C18-2 (IGR-) - Body ground
    1 MΩ or higher

  1. Release the activation prevention mechanism built into connector B (Click here).

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Tester Connection
    Specified Condition
    C18-1 (IGR+) - C18-2 (IGR-)
    1 MΩ or higher



NG
REPAIR OR REPLACE FLOOR WIRE NO. 2
OK

REPLACE CENTER AIRBAG SENSOR ASSEMBLY