SFI SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Turn the power switch ON (READY) and warm up the engine.
Turn the power switch OFF.
Connect Techstream to the DLC3.
Turn the power switch ON (IG).
Turn Techstream ON.
Enter the following menus: Powertrain / Engine and ECT / Data List.
According to the display on the tester, read items in Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Injector (Port) | Injection period of the No. 1 cylinder/ Min.: 0 ms, Max.: 32.64 ms | Idling: 1 to 3 ms (Inspection mode) | - |
| IGN Advance | Ignition timing advance for No. 1 cylinder/ Min.: -64 deg., Max.: 63.5 deg. | Idling: BTDC 7 to 15° (Inspection mode) | - |
| Calculate Load | Calculated load by ECM/ Min.: 0%, Max.: 100% |
| - |
| Vehicle Load | Vehicle load: Min.: 0 %, Max.: 25,700 % | Actual vehicle load | - |
| MAF | Air flow rate from MAF meter/ Min.: 0 g/sec., Max.: 655.35 g/sec. | Idling: 3 to 7 g/sec. (1,500 rpm) | If the value is approximately 0.0 g/sec.:
|
| Engine Speed | Engine speed/ Min.: 0 rpm, Max.: 16,383 rpm | Idling 950 to 1,050 rpm (when putting the engine in inspection mode) | - |
| Vehicle Speed | Vehicle speed/ Min.: 0 km/h, Max.: 255 km/h | Actual vehicle speed | Speed indicated on speedometer |
| Coolant Temp | Engine coolant temperature/ Min.: -40°C, Max.: 140°C | After warming up: 80 to 100°C (176 to 212°F) |
|
| Intake Air | Intake air temperature/ Min.: -40°C, Max.: 140°C | Equivalent to ambient air temperature |
|
| Air-Fuel Ratio | Air-fuel ratio: Min.: 0, Max.: 1.999 | During idling: 1,500 rpm 0.8 to 1.2 | - |
| Ambient Temperature | Ambient air temperature/ Min.: -40°C, Max.: 215°C | Equivalent to ambient air temperature |
|
| Purge Density Learn Value | Learning value of purge density/ Min.: -50, Max.: 350 | -40 to 0% Idling (Inspection mode) | Service data |
| Evap Purge Flow | Purge flow/ Min.: 0%, Max.: 102.4% | Idling: 0 to 100% | - |
| EVAP (Purge) VSV | EVAP (Purge) VSV control duty/ Min.: 0%, Max.: 100% | 0 to 100% During idling: 1,500 rpm | Order signal from ECM |
| Vapor Pressure Tank | Vapor pressure/ Min.: -4.125 kPa, Max.: 2.125 kPa | Fuel tank cap removed: 0 kPa | Pressure inside fuel tank is monitored by the vapor pressure sensor |
| Vapor Pressure Pump | Vapor pressure: Min.: 33.853 kPa, Max.: 125.596 kPa | Approximately 100 kPa: Power switch ON (IG) | EVAP system pressure monitored by canister pressure sensor |
| Vapor pressure (calculated) | Vapor pressure (calculated): Min.: -5.632 kPa, Max.: 715.264 kPa | Approximately 100 kPa: Power switch ON (IG) | EVAP system pressure monitored by canister pressure sensor |
| Knock Correct Learn Value | Correction learning value of knocking/ Min.: -64°CA, Max.: 1,984°CA | 0 to 22°CA Driving: 70 km/h (44 mph) | Service data |
| Knock Feedback Value | Feedback value of knocking/ Min.: -64°CA, Max.: 1,984°CA | -22 to 0°CA Driving: 70 km/h (44 mph) | Service data |
| Clutch Current | Clutch current: Min.: 0 A, Max.: 2.49 A | - | - |
| Electromagnetic Clutch | Electromagnetic clutch: ON or OFF | - | - |
| Accelerator Idle Position | Whether or not accelerator pedal position sensor is detecting idle/ ON or OFF | Idling: ON (inspection mode) | - |
| Throttle Fully Close Learn | Throttle valve fully closed (learned value) Min.: 0 V, Max.: 5 V | 0.4 to 0.8 V | - |
| Fail Safe Drive | Whether or not fail safe function is executed/ ON or OFF | ETCS has failed: ON | - |
| Fail Safe Drive (Main CPU) | Whether or not fail safe function is executed/ ON or OFF | ETCS has failed: ON | - |
| ST1 | Starter signal/ ON or OFF | Cranking: ON | - |
| System Guard | System guard/ ON or OFF | - | ETCS service data |
| Open Side Malfunction | Open side malfunction/ ON or OFF | - | ETCS service data |
| Throttle Pos Sensor Output | Absolute throttle position sensor/ Min.: 0%, Max.: 100% |
| Read the value with intrusive operation (active test) |
| Throttle Idle Position | Whether or not throttle position sensor is detecting idle/ ON or OFF | Idling: ON (inspection mode) | - |
| Throttle Require Position | Throttle requirement position/ Min.: 0 V, Max.: 5 V | Idling: 0.5 to 1.0 V (Inspection mode) | - |
| Throttle Sensor Position | Throttle sensor positioning/ Min.: 0%, Max.: 100% | Idling: 10 to 18% (Inspection mode) | Calculated value based on VTA1 |
| Throttle Sensor Position #2 | Throttle sensor positioning #2/ Min.: 0%, Max.: 100% | - | Calculated value based on VTA2 |
| Throttle Position No.1 | Throttle position sensor No. 1 output voltage/ Min.: 0 V, Max.: 4.98 V | - | ETCS service data |
| Throttle Position No.2 | Throttle position sensor No. 2 output voltage/ Min.: 0 V, Max.: 4.98 V | - | ETCS service data |
| Throttle Position No.1 | Throttle position No. 1/ Min.: 0 V, Max.: 5 V |
| - |
| Throttle Position No.2 | Throttle position No. 2/ Min.: 0 V, Max.: 5 V |
| Read the value with intrusive operation (active test) |
| Throttle Position Command | Throttle position command value/ Min.: 0 V, Max.: 4.9804 V | 0.5 to 4.8 V | ETCS service data |
| Throttle Sens Open Pos #1 | Throttle sensor opener position No. 1/ Min.: 0 V, Max.: 4.9804 V | 0.6 to 0.9 V | ETCS service data |
| Throttle Sens Open Pos #2 | Throttle sensor opener position No. 2/ Min.: 0 V, Max.: 4.9804 V | 2.2 to 2.6 V | ETCS service data |
| Throttle Sens Open #1(AD) | Throttle sensor opener position No. 1 (AD)/ Min.: 0 V, Max.: 4.9804 V | 0.6 to 0.9 V | ETCS service data |
| Throttle Motor | Whether or not throttle motor control is permitted/ ON or OFF | Idling: ON (Inspection mode) | Read the value with the power switch ON (Do not start engine) |
| Throttle Motor Current | Throttle motor current Min.: 0 A, Max.: 20 A | Idling: 0 to 3.0 A (Inspection mode) | - |
| Throttle Motor DUTY | Throttle motor Min.: 0%, Max.: 100% | Idling: 0.5 to 40% (Inspection mode) | - |
| Throttle Motor Current | Throttle motor current Min.: 0 A, Max.: 19.92 A | Idling: 0 to 3.0 A | - |
| Throttle Motor Open Duty | Throttle motor opening duty ratio/ Min.: 0%, Max.: 100% | Idling: 0 to 40% | When accelerator pedal is depressed, duty ratio is increased |
| Throttle Motor Close Duty | Throttle motor closed duty ratio/ Min.: 0%, Max.: 100% | Idling: 0 to 40% | When accelerator pedal is released quickly, duty ratio is increased |
| Throttle Motor Duty (Open) | Throttle motor duty ratio (open)/ Min.: 0%, Max.: 100% | - | ETCS service data |
| Throttle Motor Duty (Close) | Throttle motor duty ratio (close)/ Min.: 0%, Max.: 100% | - | ETCS service data |
| O2S B1 S2 | Heated oxygen sensor output voltage for bank 1 sensor 2/ Min.: 0 V, Max.: 1.275 V | Driving: 70 km/h (44 mph) 0.1 to 0.9 V | Performing the Control the Injection Volume or Control the Injection Volume for A/F Sensor function of the Active Test enables the technician to check voltage output of the sensor |
| AFS B1 S1 | A/F sensor output voltage for bank 1 sensor 1/ Min.: 0 V, Max.: 7.999 V | Idling: 2.8 to 3.8 V (Inspection mode) | Performing the Control the Injection Volume or Control the Injection Volume for A/F Sensor function of the Active Test enables the technician to check voltage output of the sensor |
| Total FT #1 | Total fuel trim of bank 1: Average value for fuel trim system of bank 1/ Min.: -0.5, Max.: 0.496 | Idling: -0.2 to 0.2 (Inspection mode) | - |
| Short FT #1 | Short-term fuel trim of bank 1/ Min.: -100%, Max.: 99.2% | 0 +- 20% | This item is the short-term fuel compensation used to maintain the air-fuel ratio at stoichiometric air-fuel ratio |
| Long FT #1 | Long-term fuel trim of bank 1/ Min.: -100%, Max.: 99.2% | 0 +- 20% | This item is the overall fuel compensation carried out in long-term to compensate for a continual deviation of the short-term fuel trim from the central value |
| Fuel System Status (Bank1) | Fuel system status (Bank 1) / OL or CL or OL DRIVE or OL FAULT or CL FAULT | Idling after warming up: CL (Inspection mode) |
|
| Fuel System Status (Bank2) | Fuel system status: OL or CL or OL DRIVE or OL FAULT or CL FAULT | - | Not available |
| O2FT B1 S2 | Short-term fuel trim associated with the bank 1 sensor 2/ Min.: -100%, Max.: 99.2% | 0 +- 20% | Same as Short FT #1 |
| AF Lambda B1 S1 | Short-term fuel trim associated with the bank 1 sensor 1/ Min.: 0, Max.: 1.999 |
| - |
| Catalyst Temp (B1 S1) | Catalyst temperature (Bank 1, Sensor 1)/ Min.: -40°C, Max.: 6,513.5°C | - | - |
| Catalyst Temp (B1 S2) | Catalyst temperature (Bank 1, Sensor 2)/ Min.: -40°C, Max.: 6,513.5°C | - | - |
| Sub O2S Impedance B1S2 | Sub O2S impedance B1S2: Min.:0 Ω, Max.:21247.68 Ω | 5 to 15,000 Ω | - |
| Initial Engine Coolant Temp | Initial engine coolant temperature/ Min.: -40°C, Max.: 120°C | Close to ambient air temperature | Service data |
| Initial Intake Air Temp | Initial intake air temperature/ Min.: -40°C, Max.: 120°C | Close to ambient air temperature | Service data |
| Injection Volum (Cylinder1) | Injection volume (cylinder 1)/ Min.: 0 ml, Max.: 2.048 ml | 0 to 0.5 ml | Quantity of fuel injection volume for 10 times |
| Closed Throttle Position SW | Closed throttle position switch: ON or OFF |
| - |
| Engine Oil Pressure SW | Engine oil pressure switch signal/ 0: OFF / 1: ON | Indicating ON while engine is running | - |
| ETCS Actuator Power | Whether or not electric throttle control system power is input/ ON or OFF | Idling: ON (inspection mode) | - |
| +BM Voltage | +BM voltage/ Min.: 0, Max.: 19.92182 | Idling: 10 to 15 V | ETCS service data |
| Battery Voltage | Battery voltage/ Min.: 0 V, Max.: 65.535 V | Idling: 9 to 14 V (Inspection mode) | - |
| Actuator Power Supply | Actuator power supply/ ON or OFF | Idling ON (Inspection mode) | ETCS service data |
| Atmosphere Pressure | Atmospheric pressure: Min.: 0 kPa, Max.: 255 kPa | Approximately 100 kPa: Power switch ON (IG) | - |
| EVAP Purge VSV | VSV status for EVAP control/ ON or OFF | VSV operating: ON | VSV for EVAP is controlled by the ECM (ground side duty control) |
| Fuel Pump/Speed Status | Fuel pump/speed status/ ON or OFF | Idling: ON (Inspection mode) | - |
| VVT Control Status (Bank1) | VVT control status/ ON or OFF | - | Support for VVT active test |
| Vacuum Pump | Key-off EVAP system leak detection pump status: ON or OFF | - | Active Test support data |
| EVAP System Vent Valve | Key-off EVAP system vent valve status: ON or OFF | - | Active Test support data |
| Electric Fan Motor | Electric fan motor: ON or OFF | - | Support for fan motor active test |
| Tank Bypass VSV | Tank bypass VSV: ON or OFF | - | Support for tank bypass VSV active test |
| TC and TE1 | TC and TE1 terminal of DLC3: ON or OFF | - | - |
| VVT Aim Angle (Bank1) | VVT aim angle (bank 1): Min.: 0%, Max.: 100% | Idling: 0% | VVT duty signal value during intrusive operation |
| VVT Change Angle (Bank1) | VVT change angle: Min.: 0°FR, Max.: 60°FR | Idling: 0 to 5 °FR | Displacement angle during intrusive operation |
| VVT OCV Duty (Bank1) | VVT OCV operation duty: Min.: 0%, Max.:100% | Idling: 0% | Requested duty value for intrusive operation |
| Idle Fuel Cut | Fuel cut idle: ON or OFF | Fuel cut operation: ON | Fuel cut idle = "ON" when throttle valve is fully closed and engine speed is over 2,800 rpm |
| FC TAU | Fuel cut TAU: Fuel cut during very light load: ON or OFF | Fuel cut operating: ON | The fuel cut is being performed under very light load to prevent incomplete engine combustion |
| Ignition | Ignition counter: Min.: 0, Max.: 800 | 0 to 800 | - |
| Cylinder #1 Misfire Count | Misfire ratio of the cylinder 1: Min.: 0, Max.: 255 | 0% | This item is displayed only during idling |
| Cylinder #2 Misfire Count | Misfire ratio of the cylinder 2: Min.: 0, Max.: 255 | 0% | This item is displayed only during idling |
| Cylinder #3 Misfire Count | Misfire ratio of the cylinder 3: Min.: 0, Max.: 255 | 0% | This item is displayed only during idling |
| Cylinder #4 Misfire Count | Misfire ratio of the cylinder 4: Min.: 0, Max.: 255 | 0% | This item is displayed only during idling |
| All Cylinders Misfire Count | All cylinders misfire rate: Min.: 0, Max.: 255 | 0 to 35 | - |
| Misfire RPM | Engine RPM for first misfire range: Min.: 0 rpm, Max.: 6,375 rpm | Misfire 0: 0 rpm | - |
| Misfire Load | Engine load for first misfire range: Min.: 0 g/rev, Max.: 3.98 g/rev | Misfire 0: 0 g/rev | - |
| Misfire Margin | Misfire monitoring: MIn.: -100%, Max.: 99.22% | -100 to 99.2% | Misfire detecting margin |
| # Codes | #Codes: Min.: 0, Max.: 255 | - | Number of detected DTCs |
| Check Mode | Check mode: ON or OFF | Check mode ON: ON | (Click here) |
| Misfire Test | Check mode result for misfire monitor: Complete or Incomplete | - | - |
| OXS1 Test | Check mode result for HO2 sensor: Complete or Incomplete | - | - |
| A/F Test Results (Bank1) | Check mode result for air-fuel ratio sensor: Complete or Incomplete | - | - |
| MIL | MIL status: ON or OFF | MIL ON: ON | - |
| MIL ON Run Distance | MIL ON run distance: Min.: 0 second, Max.: 65,535 seconds | Distance after DTC is detected | - |
| Running Time from MIL ON | Running time from MIL ON: Min.: 0 minute, Max.: 65,535 minutes | Equivalent to running time after MIL was ON | - |
| Engine Run Time | Engine run time: Min.: 0 second, Max.: 65,535 seconds | Time after engine start | Service data |
| Time after DTC Cleared | Time after DTC cleared: Min.: 0 minute, Max.: 65,535 minutes | Equivalent to time after DTCs were erased | - |
| Distance from DTC Cleared | Distance after DTC cleared: Min.: 0 km/h, Max.: 65535 km | Equivalent to drive distance after DTCs were erased | - |
| Warmup Cycle Cleard DTC | Warm-up cycle after DTC cleared: Min.: 0, Max.: 255 | - | Number of warm-up cycles after DTC is cleared |
| OBD Requirements | OBD requirement | OBD2 | - |
| Number of Emission DTC | Emission related DTCs | - | Number of emission related DTCs |
| Complete Parts Monitor | Comprehensive component monitor: Not Avl or Avail | - | - |
| Fuel System Monitor | Fuel system monitor: Not Avl or Avail | - | - |
| Misfire Monitor | Misfire monitor: Not Avl or Avail | - | - |
| O2S(A/FS) Monitor | O2S (A/FS ) heater monitor: Not Avl or Avail | - | - |
| O2S(A/FS) Monitor | O2S (A/FS ) heater monitor: Complete or Incomplete | - | - |
| EVAP Monitor | EVAP monitor: Not Avl or Avail | - | - |
| EVAP Monitor | EVAP monitor: Complete or Incomplete | - | - |
| Catalyst Monitor | Catalyst monitor: Not Avl or Avail | - | - |
| Catalyst Monitor | Catalyst monitor: Complete or Incomplete | - | - |
| Component Monitor ENA | Comprehensive component monitor: Unable or Enable | - | - |
| Component Monitor CMPL | Comprehensive component monitor: Complete or Incomplete | - | - |
| Fuel System Monitor ENA | Fuel system monitor: Unable or Enable | - | - |
| Fuel System Monitor CMPL | Fuel system monitor: Complete or Incomplete | - | - |
| Misfire Monitor ENA | Misfire monitor: Unable or Enable | - | - |
| Misfire Monitor CMPL | Misfire monitor: Complete or Incomplete | - | - |
| EGR Monitor ENA | EGR monitor: Unable or Enable | - | - |
| EGR Monitor CMPL | EGR monitor: Complete or Incomplete | - | - |
| Heater Monitor ENA | O2S (A/FS ) heater monitor: Unable or Enable | - | - |
| Heater Monitor CMPL | O2S (A/FS ) heater monitor: Complete or Incomplete | - | - |
| O2S(A/FS) Monitor ENA | O2S (A/FS ) monitor: Unable or Enable | - | - |
| O2S(A/FS) Monitor CMPL | O2S (A/FS ) monitor: Complete or Incomplete | - | - |
| A/C Monitor ENA | A/C monitor: Unable or Enable | - | - |
| A/C Monitor CMPL | A/C monitor: Complete or Incomplete | - | - |
| 2nd Air Monitor ENA | 2nd air monitor: Unable or Enable | - | - |
| 2nd Air Monitor CMPL | 2nd air monitor: Complete or Incomplete | - | - |
| EVAP Monitor ENA | EVAP monitor: Unable or Enable | - | - |
| EVAP Monitor CMPL | EVAP monitor: Complete or Incomplete | - | - |
| Heated Cat Monitor ENA | Heated catalyst monitor: Unable or Enable | - | - |
| Heated Cat Monitor CMPL | Heated catalyst monitor: Complete or Incomplete | - | - |
| Catalyst Monitor ENA | Catalyst monitor: Unable or Enable | - | - |
| Catalyst Monitor CMPL | Catalyst monitor: Complete or Incomplete | - | - |
| Requested Engine Torque | Requested engine torque: Min.: 0 kW, Max.: 16383.75 kW | 0 to 57 kW | Flag information for hybrid vehicle |
| HV Target Engine Speed | HV target engine speed: Min.: 0 rpm, Max.: 6375 rpm | 0 to 5000 rpm | Flag information for hybrid vehicle |
| Actual Engine Torque | Actual engine torque: Min.: -128 Nm, Max.: 127 Nm | -128 to 127 Nm | Flag information for hybrid vehicle |
| Estimated Engine Torque | Estimated engine torque: Min.: 0 Nm, Max.: 510 Nm | 0 to 120 Nm | Flag information for hybrid vehicle |
| Engine Run Time | Engine run time: Min.: 0 second, Max.: 255 seconds | 0 to 255 seconds | Flag information for hybrid vehicle |
| Request Engine Run Time | Request engine run time: Min.: 0 second, Max.: 25.5 seconds | 0 to 25.5 seconds | Flag information for hybrid vehicle |
| Judge Time Engine Ignition | Judgment time for ignition of engine: Min.: 0 second, Max.: 25.5 seconds | 0 to 25.5 seconds | Flag information for hybrid vehicle |
| Judge Time Engine Output | Judgment time for engine output: Min.: 0 second, Max.: 25.5 seconds | 0 to 25.5 seconds | Flag information for hybrid vehicle |
| Estimated Intake Port Temp | Estimated intake port temperature: Min.: -40°C, Max.: 215°C | 80 to 100°C | Flag information for hybrid vehicle |
| Fuel Level | Fuel level: Empty or Not Emp | - | Flag information for hybrid vehicle |
| ISC Learning | ISC learning: Complete or Incomplete | - | - |
| F/C for Engine Stop Req | Fuel cut for engine stop request: OFF or ON | - | Flag information for hybrid vehicle |
| Engine Independent | Engine independently operation: Not Opr or Operate | - | Flag information for hybrid vehicle |
| Racing Operation | Rev-up operation: Not Opr or Operate | - | Flag information for hybrid vehicle |
| Request Warm-up | Request warm-up: Not Req or Request | - | Flag information for hybrid vehicle |
| Engine Independent Control | Engine independently control operation: Not Opr or Operate | - | Flag information for hybrid vehicle |
| Tank Outlet Water Temp | CHS tank outlet temperature sensor output: Min: -40°C, Max: 215°C | - |
|
| Water Flow Valve | Water valve position signal: Min: 0 V, Max: 4.98 V | 0.45 to 4.6 V | Voltage varies based on valve position |
| ISC Learning Value | ISC learning value: Min: 0 L/s, Max: 19.92 L/s | - | Flag information for hybrid vehicle |
| Direction Value 1 | Direction Val Heat Storage 3 way valve (ctrl side): Min: 0 V, Max: 5 V | 2.5 to 4.5 V | - |
| Direction Value 2 | Direction Val Heat Storage 3 way valve (OBD side): Min: 0 V, Max: 5 V | 2.5 to 4.5 V | - |
| Model Code | Identifying model code | NHW20# | - |
| Engine Type | Identifying engine type | 1NZFXE | - |
| Cylinder Number | Identifying cylinder number: Min.: 0, Max.: 255 | 4 | - |
| Destination | Identifying destination | A (America) | - |
| Model Year | Identifying model year: Min.: 1900, Max.: 2155 | 2008 | - |
| System Identification | Identifying engine system | HV | - |
| ACTIVE TEST |
Turn the power switch ON (READY) and warm up the engine.
Turn the power switch OFF.
Connect Techstream to the DLC3.
Turn the power switch ON (IG).
Turn Techstream ON.
Enter the following menus: Powertrain / Engine and ECT / Active Test.
According to the display on the tester, perform items in Active Test.
| Tester Display | Test Part | Control Range |
| Control the Injection Volume | [Test Details] Control the injection volume Min.: -12.5%, Max.: 24.8% [Vehicle Condition] Engine speed: 3,000 rpm or less |
|
| Control the Injection Volume for A/F Sensor | [Test Details] Control the injection volume -12.5 or 24.8% (Change the injection volume 12.5 % or 25%) [Vehicle Condition] Engine speed: 3,000 rpm or less |
|
| Activate the VSV for Evap Control | [Test Details] Activate the VSV for EVAP control ON or OFF | (Click here) |
| Activate the VSV for Tank Bypass | [Test Details] Activate the VSV for tank bypass ON or OFF | (Click here) |
| Control the Fuel Pump / Speed | [Test Details] Control the fuel pump ON or OFF | - |
| Connect the TC and TE1 | [Test Details] Connect TC and TE1 ON or OFF | - |
| Control the Idle Fuel Cut Prohibit | [Test Details] Control the idle fuel cut prohibit ON or OFF | - |
| Control the Electric Cooling Fan | [Test Details] Control the electric cooling fan ON or OFF | - |
| Control the ETCS Open/Close Slow Speed | [Test Details] Control the ETCS opening/closing slow speed ON or OFF | Throttle valve intrusive operation |
| Control the ETCS Open/Close Fast Speed | [Test Details] Control the ETCS opening/closing fast speed ON or OFF | Throttle valve intrusive operation |
| Control the VVT Linear (Bank1) | [Test Details] Control the VVT (bank 1) Min.: -128%, Max.: 127% | - |
| Control the VVT System (Bank1) | [Test Details] Activate the VVT system (Bank 1) ON or OFF |
|
| Activate the Water Pump | [Test Details] Activate the water pump ON or OFF | Coolant heat storage water pump |
| Activate the Water Flow Valve 1 | [Test Details] Activate the water valve ON or OFF | Unused |
| Activate the Water Flow Valve 2 | [Test Details] Activate the water valve ON or OFF | Unused |
| Activate the Water Flow Valve 3 | [Test Details] Activate the water valve ON or OFF | Water valve intrusive valve operation (position when engine is in pre-heat mode) (Click here) |
| Activate the Water Flow Valve 4 | [Test Details] Activate the water valve ON or OFF | Water valve intrusive valve operation (position when hot coolant recovering) (Click here) |
| Activate the Water Flow Valve 5 | [Test Details] Activate the water valve ON or OFF | Water valve intrusive valve operation (position when engine is in normal operation) (Click here) |
| Activate the Vacuum Pump | [Test Details] Activate the leak detection pump ON or OFF | - |
| Activate the VSV for Vent Valve | [Test Details] Activate the vent valve ON or OFF | - |
| SYSTEM CHECK |
Connect Techstream to the DLC3.
Turn the power switch ON (READY).
Turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Utility.
Perform the System Check by referring to the below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Evaporative System Check (Automatic Mode) | Perform 9 steps in order to operate EVAP key-off monitor automatically | 35°C (95°F) or less |
|
| Evaporative System Check (Manual Mode) | Perform 9 steps in order to operate EVAP key-off monitor automatically | 35°C (95°F) or less |
|