When the power switch is turned on (IG), auxiliary battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes current to flow to the coil of the No. 1 integration relay (EFI MAIN relay), closing the contact and supplying power to terminals +B and +B2 of the ECM.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C10-16 (E1) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C9-16 (E1) - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the ECM connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A40-37 (IGSW) - Body ground | Power switch on (IG) | 11 to 14 V |
| *a | Front view of wire harness connector
(to ECM) |
OK
NG
Inspect the No. 1 integration relay (EFI MAIN relay) (See page Engine / Hybrid System>1NZ-FXE (ENGINE CONTROL)>INTEGRATION RELAY>INSPECTION).
OK
NG
Remove the No. 1 integration relay and ENG W/PMP relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Remove the ENG W/PMP relay connected between the checked terminals as the coil inside the relay influences the measurement value.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2C-4 - A40-2 (+B) | Always | Below 1 Ω |
| 2C-4 - A40-3 (+B2) | Always | Below 1 Ω |
| 2C-3 - A40-46 (MREL) | Always | Below 1 Ω |
| 2C-4 or A40-2 (+B) - Body ground | Always | 10 kΩ or higher |
| 2C-4 or A40-3 (+B2) - Body ground | Always | 10 kΩ or higher |
| 2C-3 or A40-46 (MREL) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the No. 1 integration relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2C-2 - Body ground | Always | Below 1 Ω |
OK
NG
Inspect the No. 1 integration relay (IG2 relay) (See page Engine / Hybrid System>1NZ-FXE (ENGINE CONTROL)>INTEGRATION RELAY>INSPECTION).
OK
NG
Remove the No. 1 integration relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2D-4 - A40-37 (IGSW) | Always | Below 1 Ω |
| 2D-4 or A40-37 (IGSW) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the No. 1 integration relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2E-1 - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector
(to No. 1 Integration Relay) |
OK
NG
Remove the No. 1 integration relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2D-2 - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the certification ECU (smart key ECU assembly) connector.
Remove the No. 1 integration relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G77-9 (IG2D) - 2D-3 | Always | Below 1 Ω |
| G77-9 (IG2D) or 2D-3 - Body ground | Always | 10 kΩ or higher |
OK
NG