Refer to the description for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0AA1 | 231 | SMRB on the HV battery positive side is stuck closed. | ·
Hybrid battery junction block assembly ·
Inverter with converter assembly ·
Hybrid vehicle control ECU ·
Wire harness and connector |
Refer to the wiring diagram for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).
When performing P0AA1-231 troubleshooting, use either a tool wrapped with vinyl insulation tape or a insulated tool. (It is extremely dangerous when a high-voltage charge passes through a non-insulated tool causing a short.)
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
If the DTCs are cleared or the cable is disconnected and reconnected to the negative (-) auxiliary battery terminal before performing repairs, turning the power switch on (READY) may cause a malfunction. Do not turn the power switch on (READY).
If P0AA1-231 is stored, the hybrid system cannot be turned on (READY).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (READY) and wait for 30 seconds or more.
Turn the power switch off and wait for 30 seconds or more.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| Only P0AA1-231 is output or P0AA1-231 and DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 658, 791 | Generator Control Module |
| P0A1B-786, 794 | Drive Motor "A" Control Module |
| P0A1D-148 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P2511-149 | HV CPU Power Relay Sense Circuit Intermittent No Continuity |
| P3004-132 | High Voltage Power Resource |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| P324E-788 | MG-ECU Power Relay Intermittent Circuit |
| U0110 (all INF codes)*1 | Lost Communication with Drive Motor Control Module "A" |
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0AA1-231 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data of DTC P0AA1-231.
| Result | Proceed to |
|---|---|
| "VL-Voltage before Boosting" is 55 V or more. | A |
| "VL-Voltage before Boosting" is less than 55 V. | B |
If VH-Voltage after Boosting is output even when an off command is being sent to the system main relay (positive side), P0AA1-231 is output. If the difference between the "VL-Voltage before Boosting" and the "VH-Voltage after Boosting" is large, it is determined that there is an inverter (VH sensor) malfunction.
Turn the power switch off.
A
B
OK
NG
NEXT
Check the connection condition of the MG5 floor wire connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter (See page General>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE).
The connector is connected securely.
The terminals are not deformed and are connected securely.
No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
NEXT
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid vehicle battery cover panel LH (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).
Check the connector connections and contact pressure of the relevant terminals for the hybrid battery junction block assembly connector (See page General>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE ).
The connector is connected securely and there are no contact pressure problems.
Install the No. 1 hybrid vehicle battery cover panel LH.
OK
NG
NEXT
Check the installation condition of the G6 ground wire.
The G6 ground wire is securely installed.
OK
NG
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid vehicle battery cover panel LH (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).
Disconnect connector M40 from the hybrid battery junction block assembly.
Disconnect connector G80 from the hybrid vehicle control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G80-4 (SMRB) - M40-1 (SMRB) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G80-4 (SMRB) and M40-1 (SMRB) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Rear view of wire harness connector
(to Hybrid Battery Junction Block Assembly) |
Connect the hybrid vehicle control ECU connector.
Connect the hybrid battery junction block assembly connector.
Install the No. 1 hybrid vehicle battery cover panel LH.
OK
NG
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid vehicle battery cover panel LH (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).
Disconnect connector M40 from the hybrid battery junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M40-2 (GND) - Body ground | Power switch off | Below 1 Ω |
| *a | Rear view of wire harness connector
(to Hybrid Battery Junction Block Assembly) |
Connect the hybrid battery junction block assembly connector.
Install the No. 1 hybrid vehicle battery cover panel LH.
OK
NG
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid vehicle battery cover panel LH (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).
Disconnect connector M40 from the hybrid battery junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M40-1 (SMRB) - M40-2 (GND) | -40 to 80 °C (-40 to 176°F) | 25.0 to 59.0 Ω |
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Connect the hybrid battery junction block assembly connector.
Install the No. 1 hybrid vehicle battery cover panel LH.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| P5-1 (CBI) - A-1 (+) | Power switch off | 10 kΩ or higher |
If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.
If the result of reading the freeze frame data is A, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
Install the No. 2 hybrid battery shield sub-assembly.
OK
NG
NEXT
Install the service plug grip.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Clear the DTCs (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DTC CHECK / CLEAR).
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Data List / Power Resource VB, VL-Voltage before Boosting.
According to the display on the intelligent tester, read the Data List and monitor the values of "Power Resource VB" and "VL-Voltage before Boosting" for 3 minutes.
| Result | Proceed to |
|---|---|
| Difference between "Power Resource VB" and "VL-Voltage before Boosting" is always less than 100 V. | A |
| Difference between "Power Resource VB" and "VL-Voltage before Boosting" is 100 V or more. | B |
A
B