The MG ECU located in the inverter with converter assembly detects the temperature of the generator inverter using the temperature sensor built into the generator inverter. If necessary, the MG ECU will limit inverter output to help prevent generator inverter overheating. The power management control ECU also detects malfunctions in the sensor based on the temperature sensor values. The inverter with converter assembly detects malfunctions in the generator inverter temperature sensor and its wiring.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0BCD | 315 | Temperature calculated by power management control ECU and actual temperature are different for 10 seconds or more. | ·
Inverter cooling system ·
Cooling fan system ·
Inverter with converter assembly |
| P0BD0 | 314 | Unusual sudden change in generator inverter temperature sensor output occurs and the offset continues, or unusual sudden change in generator inverter temperature sensor output occurs repeatedly. |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 90 seconds or more.
Drive the vehicle for approximately 10 minutes referring to the following freeze frame data or Data List items: "Vehicle Spd".
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| Only P0BCD-315 or P0BD0-314 is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A93-346 | Inverter Cooling System Performance |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P314A-828 | Inverter Coolant Pump Speed Signal |
P0BCD-315 or P0BD0-314 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
OK
NG
A
B
C
OK
NG
OK
NG
A
B
NEXT