G9200
1.REMOVE INVERTER WITH CONVERTER ASSEMBLY
G9110
2.REMOVE INVERTER BRACKET ASSEMBLY
G9040
3.REMOVE INVERTER WATER PUMP ASSEMBLY
Disconnect the 2 water hoses.
Put pieces of cloth into the pipes and in the disconnected hoses to prevent foreign matter from entering the inverter water pump and cooling system.
Disconnect the connector.
Apply insulating tape to the connectors of the wire harness and inverter water pump assembly with motor to prevent the entry of coolant.
Remove the 3 bolts and the inverter water pump assembly.
G9031A
4.REMOVE HV WATER PUMP BRACKET SUB-ASSEMBLY
Disconnect the clamp.
Remove the 2 bolts and the HV water pump bracket sub-assembly.