1.INSTALL POWER SWITCH (for RHD)
Connect the power switch connector.
Engage the 2 claws to install the power switch.
2.INSTALL UPPER INSTRUMENT PANEL ASSEMBLY (for RHD)
3.INSTALL POWER SWITCH (for LHD)
Connect the power switch connector.
Engage the 2 claws to install the power switch.
55405B
4.INSTALL CENTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY (for LHD)
5.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL (for LHD)
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).
58165F
6.INSTALL FRONT FLOOR COVER RH (for LHD)