Home › Engine / Hybrid System › 1NZ-FXE STARTING › POWER SWITCH › 2011.12–2014.12
RM2170E _51 Engine / Hybrid System _057011 1NZ-FXE STARTING _0277984 POWER SWITCH A

1NZ-FXE STARTING  POWER SWITCH  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


Hide 3.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL (for LHD)

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 55405B 4.REMOVE CLUSTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY (for LHD)

Hide 5.REMOVE POWER SWITCH (for LHD)

a.
A267423

Disengage the 2 claws and remove the power switch.


b.

Disconnect the power switch connector.


Hide 6.REMOVE UPPER INSTRUMENT PANEL ASSEMBLY (for RHD)

Hide 7.REMOVE POWER SWITCH (for RHD)

a.
A267424

Disengage the 2 claws and remove the power switch.


b.

Disconnect the power switch connector.