The main body ECU (multiplex network body ECU) detects the condition of the back door lock assembly using this circuit.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Data List.
Read the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Back Door Courtesy SW | Back door courtesy switch signal/ON or OFF | ON: Back door open
OFF: Back door closed |
- |
Normal conditions listed above are displayed.
OK
NG
Remove the back door lock assembly (See page Vehicle Interior>DOOR LOCK>BACK DOOR LOCK>REMOVAL).
Inspect the back door lock assembly (See page Vehicle Interior>DOOR LOCK>BACK DOOR LOCK>INSPECTION).
Back door lock assembly is normal.
OK
NG
Disconnect the 3D instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T5-3 (D+) - 3D-35 | Always | Below 1 Ω |
| T5-3 (D+) - Body ground | Always | 10 kΩ or higher |
| T5-2 (ACT-) - Body ground | Always | Below 1 Ω |
OK
NG
Remove the instrument panel junction block assembly (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3D-35 - MB-20 (BCTY) | Always | Below 1 Ω |
OK
NG