The combination meter assembly blinks or turns off the seat belt warning light on the combination meter assembly in accordance with the state of the front seat inner belt assembly (for driver).
The seat belt warning light on the combination meter assembly is used for both the driver seat and front passenger seat.
The seat belt warning system uses the CAN communication system. First, confirm that there is no malfunction in the communication system by checking communication function of the CAN communication system. Refer to the How to Proceed with Troubleshooting procedure (See page Vehicle Interior>SEAT BELT>SEAT BELT WARNING SYSTEM (w/o Occupant Classification System)>HOW TO PROCEED WITH TROUBLESHOOTING).
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Data List.
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| D Seat Buckle SW | Driver seat belt buckle switch signal/ON or OFF | ON: Driver seat belt fastened
OFF: Driver seat belt unfastened |
- |
ON or OFF appears on the tester screen according to the driver seat belt condition.
OK
NG
Remove the front seat inner belt assembly (for driver) (See page Vehicle Interior>SEAT BELT>FRONT SEAT INNER BELT ASSEMBLY>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 - 3 | Driver seat belt unfastened | Below 1 Ω |
| 2 - 3 | Driver seat belt fastened | 10 kΩ or higher |
| *a | Component without harness connected
(Front Seat Inner Belt Assembly (for Driver)) |
OK
NG
Remove the main body ECU (multiplex network body ECU) (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Disconnect the 3D instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| MB-18 (DBKL) - 3D-34 | Always | Below 1 Ω |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3D-34 - M10-3 | Always | Below 1 Ω |
| M10-3 - Body ground | Always | 10 kΩ or higher |
| M10-2 - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3D-34 - M8-3 | Always | Below 1 Ω |
| M8-3 - Body ground | Always | 10 kΩ or higher |
| M8-2 - Body ground | Always | Below 1 Ω |
OK
NG