The evaporator temperature sensor (No. 1 cooler thermistor) is installed on the evaporator in the air conditioner unit to detect the temperature of the air that has passed through the evaporator. Its signal is used for air conditioning control. It sends signals to the air conditioning amplifier assembly. The resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the evaporator temperature sensor (No. 1 cooler thermistor) and reads voltage changes as the resistance of the evaporator temperature sensor (No. 1 cooler thermistor) changes. This sensor is used for frost prevention.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1413/13 | Open or short in evaporator temperature sensor (No. 1 cooler thermistor) circuit | ·
Evaporator temperature sensor (No. 1 cooler thermistor) ·
Air conditioning harness assembly ·
Air conditioning amplifier assembly |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Evaporator Fin Thermistor | Evaporator temperature sensor (No. 1 cooler thermistor) /
Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
(See pageVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>PROBLEM SYMPTOMS TABLE)
C
Remove the evaporator temperature sensor (No. 1 cooler thermistor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>REMOVAL).
Disconnect the a1 evaporator temperature sensor (No. 1 cooler thermistor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| b1-1 - b1-2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| b1-1 - b1-2 | -5°C (23°F) | 5.65 to 6.95 kΩ |
| b1-1 - b1-2 | 0°C (32°F) | 4.40 to 5.35 kΩ |
| b1-1 - b1-2 | 5°C (41°F) | 3.40 to 4.15 kΩ |
| b1-1 - b1-2 | 10°C (50°F) | 2.70 to 3.25 kΩ |
| b1-1 - b1-2 | 15°C (59°F) | 2.14 to 2.58 kΩ |
| b1-1 - b1-2 | 20°C (68°F) | 1.71 to 2.05 kΩ |
| b1-1 - b1-2 | 25°C (77°F) | 1.38 to 1.64 kΩ |
| b1-1 - b1-2 | 30°C (86°F) | 1.11 to 1.32 kΩ |
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
| *a | Component without harness connected
(Evaporator Temperature Sensor (No. 1 Cooler Thermistor)) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Allowable Range |
| *e | Temperature (°C (°F)) |
OK
NG
Remove the air conditioning harness assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z1-6 (TEA) - b1-2 | Always | Below 1 Ω |
| z1-5 (SGA) - b1-1 | Always | Below 1 Ω |
| z1-6 (TEA) - Body ground | Always | 10 kΩ or higher |
| z1-5 (SGA) - Body ground | Always | 10 kΩ or higher |
| *a | Front view of wire harness connector
(to Air Conditioning Amplifier Assembly) |
| *b | Front view of wire harness connector
(to Evaporator Temperature Sensor (No. 1 Cooler Thermistor)) |
OK
NG