The combination meter assembly receives the hazard warning signal switch ON signal and controls the operation of the hazard warning lights.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Combination Meter / Data List.
Read the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Hazard Flasher Switch | Hazard switch signal/ON or OFF | ON: Hazard switch on
OFF: Hazard switch off |
- |
Normal conditions listed above are displayed.
OK
NG
Remove the hazard warning signal switch assembly (See page Vehicle Exterior>LIGHTING (EXT)>HAZARD WARNING SWITCH>REMOVAL).
Inspect the hazard warning signal switch assembly (See page Vehicle Exterior>LIGHTING (EXT)>HAZARD WARNING SWITCH>INSPECTION).
OK
NG
Disconnect the G3 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G2-4 (TB) - G3-3 (HAZ) | Always | Below 1 Ω |
| G2-4 (TB) - Body ground | Always | 10 kΩ or higher |
| G2-1 (E) - Body ground | Always | Below 1 Ω |
OK
NG