Home › Vehicle Exterior › LIGHTING (EXT) › LIGHTING SYSTEM › from 2017.06
RM2170E _59 Vehicle Exterior _057049 LIGHTING (EXT) _0278196 LIGHTING SYSTEM J

LIGHTING (EXT)  LIGHTING SYSTEM  Daytime Running Light Relay Circuit  


DESCRIPTION

The main body ECU (multiplex network body ECU) controls the daytime running lights.

WIRING DIAGRAM

E374290E01
1.979,0.99 3.5,1.219 1.521,0.229 10 false from Auxiliary Battery 5.344,1.156 6.26,1.354 0.917,0.198 10 false DRL 6.042,2.01 6.958,2.208 0.917,0.198 10 false DRLE 5.781,1.906 6.167,2.104 0.385,0.198 10 false 26 4.719,0.823 5.104,1.021 0.385,0.198 10 false 1 4.677,1 5.063,1.198 0.385,0.198 10 false 3E 4.677,1.302 5.063,1.5 0.385,0.198 10 false 10 4.677,1.49 5.063,1.688 0.385,0.198 10 false 3B 4.698,1.823 5.083,2.021 0.385,0.198 10 false 33 4.688,2 5.073,2.198 0.385,0.198 10 false 3B 4.313,1.917 4.698,2.115 0.385,0.198 10 false 2 3.406,1.917 3.792,2.115 0.385,0.198 10 false 1 3.406,2.427 3.792,2.625 0.385,0.198 10 false 5 4.313,2.438 4.698,2.635 0.385,0.198 10 false 3 3.802,2.844 4.719,3.042 0.917,0.198 10 false DRL 4.844,3.573 5.906,4.292 1.063,0.719 10 false Instrument Panel Junction Block Assembly 5.365,4.76 7.01,5.344 1.646,0.583 10 false Main Body ECU (Multiplex Network Body ECU) 0.604,4.625 3.5,4.927 2.896,0.302 10 false Daytime Running Light Assembly RH 0.604,4.438 0.99,4.635 0.385,0.198 10 false A81 0.896,3.781 1.302,4.021 0.406,0.24 10 false 1 1.063,3.792 1.448,3.99 0.385,0.198 10 false E 2.656,3.792 3.042,3.99 0.385,0.198 10 false 2 2.458,1.677 2.844,1.875 0.385,0.198 10 false B 1.052,1.677 1.438,1.875 0.385,0.198 10 false E 0.573,2.208 0.958,2.406 0.385,0.198 10 false A83 0.573,2.354 2.948,2.656 2.375,0.302 10 false Daytime Running Light Assembly LH 5.354,4.542 5.74,4.74 0.385,0.198 10 false MB 0.875,1.677 1.26,1.875 0.385,0.198 10 false 1 2.656,1.677 3.042,1.875 0.385,0.198 10 false 2 2.438,3.802 2.823,4 0.385,0.198 10 false B 3.948,1.135 4.719,1.333 0.771,0.198 10 false DC/DC

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

1.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Main Body / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Main Body
Tester Display Measurement Item Control Range Diagnostic Note
Daytime Running Light Daytime running lights OFF or ON -

OK:

Daytime running lights illuminate.




OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

2.INSPECT DRL RELAY
2.INSPECT DRL RELAY

OK

3.CHECK HARNESS AND CONNECTOR (DRL RELAY INPUT VOLTAGE)

NG

REPLACE DRL RELAY

3.CHECK HARNESS AND CONNECTOR (DRL RELAY INPUT VOLTAGE)
a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
1 (DRL relay) - Body ground Power switch off 11 to 14 V
5 (DRL relay) - Body ground Power switch off 11 to 14 V




OK

4.CHECK HARNESS AND CONNECTOR (DRL RELAY - DAYTIME RUNNING LIGHT ASSEMBLY)

NG

7.CHECK HARNESS AND CONNECTOR (DRL RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
4.CHECK HARNESS AND CONNECTOR (DRL RELAY - DAYTIME RUNNING LIGHT ASSEMBLY)
a.

Disconnect the A83 daytime running light assembly LH connector.


b.

Disconnect the A81 daytime running light assembly RH connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 (DRL relay) - A83-2 (B) Always Below 1 Ω
3 (DRL relay) - A81-2 (B) Always Below 1 Ω
3 (DRL relay) or A83-2 (B) - Body ground Always 10 kΩ or higher
3 (DRL relay) or A81-2 (B) - Body ground Always 10 kΩ or higher




OK

5.CHECK HARNESS AND CONNECTOR (DRL RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (DRL RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
a.

Disconnect the 3B instrument panel junction block assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (DRL relay) - 3B-33 Always Below 1 Ω
2 (DRL relay) or 3B-33 - Body ground Always 10 kΩ or higher




OK

6.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
E259633C08
4.583,0.167 4.917,0.417 0.333,0.25 1.083,0.167 1.417,0.417 0.333,0.25 5.604,1.406 5.854,0.958 false 0.083,0.083 0.396,0.281 0.313,0.198 10 false *a 1.177,0.208 1.49,0.406 0.313,0.198 10 false 3B 4.656,0.208 4.969,0.406 0.313,0.198 10 false MB 5.365,1.458 5.854,1.656 0.49,0.198 10 false DRLE
*a Component without harness connected
(Instrument Panel Junction Block Assembly)
- -


a.

Remove the instrument panel junction block assembly.

Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL


b.

Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3B-33 - MB-26 (DRLE) Always Below 1 Ω




OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)

NG

REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

7.CHECK HARNESS AND CONNECTOR (DRL RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
a.

Disconnect the 3B instrument panel junction block assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (DRL relay) - 3B-10 Always Below 1 Ω
5 (DRL relay) - 3B-10 Always Below 1 Ω
1 (DRL relay) or 3B-10 - Body ground Always 10 kΩ or higher
5 (DRL relay) or 3B-10 - Body ground Always 10 kΩ or higher




OK

8.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
E371711C01
4.698,0.229 5.104,0.448 0.406,0.219 1.865,0.208 2.271,0.427 0.406,0.219 0.24,0.229 0.552,0.427 0.313,0.198 10 false *a 4.802,0.25 5.115,0.448 0.313,0.198 10 false 3E 1.979,0.229 2.292,0.427 0.313,0.198 10 false 3B
*a Component without harness connected
(Instrument Panel Junction Block Assembly)
- -


a.

Remove the instrument panel junction block assembly.

Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3E-1 - 3B-10 Always Below 1 Ω




OK

9.CHECK HARNESS AND CONNECTOR (AUXILIARY BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)

NG

REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

9.CHECK HARNESS AND CONNECTOR (AUXILIARY BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
a.

Disconnect the 3E instrument panel junction block assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
3E-1 - Body ground Power switch off 11 to 14 V




OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR