Home › Power Source / Network › 1NZ-FXE BATTERY / CHARGING › AUXILIARY BATTERY › from 2017.06
RM2170E _57 Power Source / Network _057031 1NZ-FXE BATTERY / CHARGING _0278063 AUXILIARY BATTERY A

1NZ-FXE BATTERY / CHARGING  AUXILIARY BATTERY  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:
·

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

When replacing the auxiliary battery, use a new auxiliary battery of the same dimensions with a collective ventilation system and a capacity of 35 Ah or more at a 20-hour rate.



Hide 3.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL

a.
A407325

Loosen the nut, and disconnect the cable from the negative (-) auxiliary battery terminal.

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION



Hide 4.REMOVE AUXILIARY BATTERY

a.
A405727

Disengage the 2 claws and open the battery terminal cap.


b.

Loosen the nut and disconnect the cable from the positive (+) auxiliary battery terminal.


c.
A405728

Disconnect the battery hose from the auxiliary battery.


d.
A405729

Remove the bolt and No. 2 battery clamp from the battery carrier sub-assembly.


e.

Remove the auxiliary battery from the battery carrier sub-assembly.


f.
A401434

Remove the battery insulator from the auxiliary battery.