1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When replacing the auxiliary battery, use a new auxiliary battery of the same dimensions with a collective ventilation system and a capacity of 35 Ah or more at a 20-hour rate.
58165F
2.REMOVE FRONT FLOOR COVER RH
3.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
Loosen the nut, and disconnect the cable from the negative (-) auxiliary battery terminal.
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
4.REMOVE AUXILIARY BATTERY
Disengage the 2 claws and open the battery terminal cap.
Loosen the nut and disconnect the cable from the positive (+) auxiliary battery terminal.
Disconnect the battery hose from the auxiliary battery.
Remove the bolt and No. 2 battery clamp from the battery carrier sub-assembly.
Remove the auxiliary battery from the battery carrier sub-assembly.
Remove the battery insulator from the auxiliary battery.