Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.10–2014.11
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A78-113  Drive Motor "A" Inverter Performance  


DESCRIPTION

For a description of the inverter (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A78-266).

If the motor inverter overheats, has a circuit malfunction, or has an internal short, the inverter transmits this information to the MG ECU via the motor inverter fail signal line.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A78 113 Motor inverter fail signal detection
(System overcurrent)
·

Hybrid vehicle generator assembly

·

Hybrid vehicle motor assembly

·

Generator cable

·

Motor cable

·

Inverter with converter assembly

·

Power management control ECU

·

PCU fuse

·

Wire harness or connector



WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A1A-200 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A1A-200).

Refer to the wiring diagram for DTC P324E-788 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P324E-788).

Refer to the wiring diagram for DTC U0110-159 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>U0110-159).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals of the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (READY) and wait for 5 seconds or more.

2.

Perform a road test according to the freeze frame data "Vehicle Spd" for approximately 10 minutes.



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

Result:
Result Proceed to
P0A78-113 is set before any of the DTCs in the table below are set. A
Any of the DTCs including pending DTCs in the table 1 below are set before P0A78-113 is set. B
Any of the DTCs including pending DTCs in the table 2 below are set before P0A78-113 is set. C


Table 1
DTC No. Relevant Diagnosis
P0AC0-817 Hybrid Battery Pack Current Sensor Circuit Range / Performance
P3004-131 High Voltage Power Resource

Table 2
DTC No. Relevant Diagnosis
P0A7F-123 Hybrid Battery Pack Deterioration
P0A80-123 Replace Hybrid Battery Pack
P0A9C-123 Hybrid Battery Temperature Sensor "A" Range / Performance
P0A9D-123 Hybrid Battery Temperature Sensor "A" Circuit Low
P0A9E-123 Hybrid Battery Temperature Sensor "A" Circuit High
P0ABF-123 Hybrid Battery Pack Current Sensor Circuit
P0AC0-123 Hybrid Battery Pack Current Sensor Circuit Range / Performance
P0AC1-123 Hybrid Battery Pack Current Sensor Circuit Low
P0AC2-123 Hybrid Battery Pack Current Sensor Circuit High
P0AC6-123 Hybrid Battery Temperature Sensor "B" Range / Performance
P0AC7-123 Hybrid Battery Temperature Sensor "B" Circuit Low
P0AC8-123 Hybrid Battery Temperature Sensor "B" Circuit High
P0ACB-123 Hybrid Battery Temperature Sensor "C" Range / Performance
P0ACC-123 Hybrid Battery Temperature Sensor "C" Circuit Low
P0ACD-123 Hybrid Battery Temperature Sensor "C" Circuit High
P0AE9-123 Hybrid Battery Temperature Sensor "D" Range / Performance
P0AEA-123 Hybrid Battery Temperature Sensor "D" Circuit Low
P0AEB-123 Hybrid Battery Temperature Sensor "D" Circuit High
P0AFC-123 Hybrid Battery Pack Sensor Module
P0B10-123 Hybrid Battery Pack Current Sensor "B" Circuit Low
P0B11-123 Hybrid Battery Pack Current Sensor "B" Circuit High
P0B13-123 Hybrid Battery Pack Current Sensor "A"/"B" Correlation
P0BC3-123 Hybrid Battery Temperature Sensor "E" Range / Performance
P0BC4-123 Hybrid Battery Temperature Sensor "E" Circuit Low
P0BC5-123 Hybrid Battery Temperature Sensor "E" Circuit High
P0C34-123 Hybrid Battery Temperature Sensor "F" Range / Performance
P0C35-123 Hybrid Battery Temperature Sensor "F" Circuit Low
P0C36-123 Hybrid Battery Temperature Sensor "F" Circuit High
P3011-123 Battery Block 1 Becomes Weak
P3012-123 Battery Block 2 Becomes Weak
P3013-123 Battery Block 3 Becomes Weak
P3014-123 Battery Block 4 Becomes Weak
P3015-123 Battery Block 5 Becomes Weak
P3016-123 Battery Block 6 Becomes Weak
P3017-123 Battery Block 7 Becomes Weak
P3018-123 Battery Block 8 Becomes Weak
P301A-123 Open in Hybrid Battery Cell Voltage Detection Circuit
P301B-123 Hybrid Battery Cell Voltage Detection Circuit Range/Performance
P3065-123 Hybrid Battery Temperature Sensor Range/Performance Stuck "A
P306A-123 Hybrid Battery Temperature Sensor Range / Performance Stuck "B"
P31AA-123 Hybrid Battery Cell High Voltage
P31AB-123 Hybrid Battery Cell Low Voltage
P31AC-123 Hybrid Battery Cell Extreme High Voltage
P31B3-123 Hybrid Battery Voltage High
U029A-123 Lost Communication with Hybrid Battery Pack Sensor Module

HINT:
·

Refer to the freeze frame data to determine the order in which the DTCs were set.

·

P0A78-113 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.




e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

C

2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

Result:
Result Proceed to
P0A78-202 is not output. A
P0A78-202 is also output. B


NOTICE:
·

If P0A78-202 is output, troubleshoot it first. After completing the troubleshooting for P0A78-202, return to perform troubleshooting for this DTC.

·

Parts repaired or replaced during troubleshooting for P0A78-202 do not need to be re-inspected in this diagnosis procedure.




e.

Turn the power switch off.



A

3.CHECK DTC OUTPUT (HYBRID CONTROL)

B

3.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

HINT:
·

If P0A78-202 was not output in step 2 of this diagnosis procedure, check reference 1 below.

·

If P0A78-202 was output in step 2 of this diagnosis procedure, repair that DTC first, then check reference 2 below.



Result:
Result Proceed to
Only P0A78-113 is output, or DTCs other than the ones in the table below are also output. A
Any of the following DTCs including pending DTCs in the table 1 and 3 below are also output. B
Any of the following DTCs in the table 2 and 4 below are also output. C


Table 1 (reference 1)
DTC No. Relevant Diagnosis
P0A1A (all INF codes)*1 Generator Control Module
P0A1B (all INF codes)*1 Drive Motor "A" Control Module
P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
P0A3F-243 Drive Motor "A" Position Sensor Circuit
P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
P0A41-245 Drive Motor "A" Position Sensor Circuit Low
P0A4B-253 Generator Position Sensor Circuit
P0A4C-513 Generator Position Sensor Circuit Range/Performance
P0A4D-255 Generator Position Sensor Circuit Low
P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
P0A72 (all INF codes)*1 Generator Phase V Current
P0A75 (all INF codes)*1 Generator Phase W Current
P0A78-266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance
P0A7A-325, 344, 517, 518, 809, 810, 811 Generator Inverter Performance
P0A90-509 Drive Motor "A" Performance
P0A92-521 Hybrid Generator Performance
P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 DC/DC Converter Performance
P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
P0C76-523 Hybrid Battery System Discharge Time Too Long
P3000-388, 389, 603 HV Battery Malfunction
P3004-133, 803 High Voltage Power Resource

Table 2 (reference 1)
DTC No. Relevant Diagnosis
P0A95-123 High Voltage Fuse
P31B4-123 Extreme Charging Current Caused by Hybrid Battery High Voltage
P31B5-123 Abnormal Current Caused by Continuous Current from Hybrid Battery

Table 3 (reference 2)
DTC No. Relevant Diagnosis
P0A1A (all INF codes)*1 Generator Control Module
P0A1B (all INF codes)*1 Drive Motor "A" Control Module
P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
P0A3F-243 Drive Motor "A" Position Sensor Circuit
P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
P0A41-245 Drive Motor "A" Position Sensor Circuit Low
P0A4B-253 Generator Position Sensor Circuit
P0A4C-513 Generator Position Sensor Circuit Range/Performance
P0A4D-255 Generator Position Sensor Circuit Low
P0A60-294 Drive Motor "A" Phase V Current
P0A63-302 Drive Motor "A" Phase W Current
P0A72 (all INF codes)*1 Generator Phase V Current
P0A75 (all INF codes)*1 Generator Phase W Current
P0A78-266, 267, 279, 287, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance
P0A7A-325, 344, 517, 518, 809, 810, 811 Generator Inverter Performance
P0A92-521 Hybrid Generator Performance
P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 DC/DC Converter Performance
P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
P0C76-523 Hybrid Battery System Discharge Time Too Long
P3000-388, 389, 603 HV Battery Malfunction
P3004-133, 803 High Voltage Power Resource

Table 4 (reference 2)
DTC No. Relevant Diagnosis
P0A95-123 High Voltage Fuse
P31B4-123 Extreme Charging Current Caused by Hybrid Battery High Voltage
P31B5-123 Abnormal Current Caused by Continuous Current from Hybrid Battery

HINT:
·

*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

·

P0A78-113 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.




e.

Turn the power switch off.



A

4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

C

4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

OK

5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

NG

CONNECT SECURELY

5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

OK

6.CHECK GENERATOR RESOLVER

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK GENERATOR RESOLVER

OK

7.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

NG

19.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
7.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

OK

8.CHECK MOTOR RESOLVER

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK MOTOR RESOLVER

OK

9.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

NG

21.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
9.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.


c.
A215643E14
2.063,0.5 2.208,0.656 0.146,0.156 10 true A 2.031,0.75 2.177,0.906 0.146,0.156 10 true A 1.927,0.969 2.073,1.125 0.146,0.156 10 true A 1.583,0.042 1.729,0.198 0.146,0.156 10 true B 1.229,0.323 1.375,0.479 0.146,0.156 10 true B

Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

Specified Condition:
Bolt A:

T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

Bolt B:

T=9.2 N*m (94 kgf*cm, 81 in.*lbf)


NOTICE:
·

Make sure that the tightening torque of the bolt A is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

·

Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).




d.

Disconnect the generator cable from the inverter with converter assembly.


e.

Check for arc marks at the bolts and terminals for the generator cable.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



f.

Connect the generator cable to the inverter with converter assembly.


g.

Install the inverter cover.



A

10.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

10.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.


c.
A255124E06
2.333,0.323 2.458,0.479 0.125,0.156 10 true A 2.292,0.542 2.417,0.698 0.125,0.156 10 false A 2.188,0.74 2.313,0.896 0.125,0.156 10 false A 1.469,0.208 1.594,0.365 0.125,0.156 10 true B 2.052,0.083 2.177,0.24 0.125,0.156 10 false B

Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

Specified Condition:
Bolt A:

T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

Bolt B:

T=9.2 N*m (94 kgf*cm, 81 in.*lbf)


NOTICE:
·

Make sure that the tightening torque of the bolt A is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

·

Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).




d.

Disconnect the motor cable from the inverter with converter assembly.


e.

Check for arc marks at the bolts and terminals for the motor cable.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



f.

Connect the motor cable to the inverter with converter assembly.


g.

Install the inverter cover.



A

11.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

11.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.


c.

Disconnect the generator cable and motor cable from the inverter with converter assembly.


d.
U190548E02
0.938,1 0.583,1 false 1.344,1.771 1.219,1.938 false 1.729,1.802 1.729,1.927 false 2.125,1.781 2.271,1.948 false 0.083,0.052 0.292,0.281 0.208,0.229 10 false *1 0.385,0.927 0.594,1.156 0.208,0.229 10 false *2 1.104,1.958 1.313,2.125 0.208,0.167 10 false W 1.698,1.969 1.844,2.125 0.146,0.156 10 false U 2.26,1.958 2.469,2.125 0.208,0.167 10 false V 2.823,1.094 3.073,1.406 0.25,0.313 10 false f1

Check MG1 for an interphase short using a milliohmmeter.

i.

Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

HINT:

If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.


Standard Resistance:
Tester Connection Condition Specified Condition
f1-1 (W) - f1-2 (U) Power switch off 89.5 to 98.9 mΩ
f1-2 (U) - f1-3 (V) Power switch off 89.5 to 98.9 mΩ
f1-3 (V) - f1-1 (W) Power switch off 89.5 to 98.9 mΩ


Text in Illustration
*1 Generator Cable
(Inverter with Converter Assembly Side)
*2 Shield Ground

HINT:

To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).

R20 = Rt / {1 + 0.00393 X (T - 20)}


The calculation is based on the following:

R20: Resistance at 20°C (68°F) (mΩ)

Rt: Measured resistance (mΩ)

T: Temperature when the resistance is measured (°C)





e.

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
f1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher



f.

Connect the generator cable and motor cable.


g.

Install the inverter cover.



OK

12.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

NG

26.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
12.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.


c.

Disconnect the generator cable and motor cable from the inverter with converter assembly.


d.
U190551E02
0.938,0.99 0.594,1 false 1.354,1.76 1.229,1.958 false 1.729,1.76 1.729,1.948 false 2.115,1.771 2.219,1.969 false 0.094,0.063 0.271,0.24 0.177,0.177 10 false *1 0.406,0.917 0.583,1.094 0.177,0.177 10 false *2 1.135,1.969 1.313,2.146 0.177,0.177 10 false W 1.688,1.969 1.875,2.146 0.188,0.177 10 false U 2.198,1.979 2.375,2.156 0.177,0.177 10 false V 2.833,1.031 3.104,1.198 0.271,0.167 10 false e1

Check MG2 for an interphase short using a milliohmmeter.

i.

Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

HINT:

If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.


Standard Resistance:
Tester Connection Condition Specified Condition
e1-1 (W) - e1-2 (U) Power switch off 152.6 to 169.0 mΩ
e1-2 (U) - e1-3 (V) Power switch off 157.6 to 174.0 mΩ
e1-3 (V) - e1-1 (W) Power switch off 151.6 to 168.0 mΩ


Text in Illustration
*1 Motor Cable
(Inverter with Converter Assembly Side)
*2 Shield Ground

HINT:

To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).

R20 = Rt / {1 + 0.00393 X (T - 20)}


The calculation is based on the following:

R20: Resistance at 20°C (68°F) (mΩ)

Rt: Measured resistance (mΩ)

T: Temperature when the resistance is measured (°C)





e.

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
e1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher



f.

Connect the generator cable and motor cable.


g.

Install the inverter cover.



OK

13.CHECK FUSE (PCU)

NG

28.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
13.CHECK FUSE (PCU)
a.
A237660E03
2.198,2.031 2.938,2.094 false 0.115,0.115 0.333,0.344 0.219,0.229 10 false *1 2.979,2.042 3.198,2.271 0.219,0.229 10 false *2

Remove the PCU fuse from the engine room relay block and junction block assembly.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
PCU fuse terminal Always Below 1Ω


Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 PCU fuse


c.

Install the PCU fuse.



OK

14.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

NG

23.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE)
14.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.
U154307E03
2.135,0.979 2,0.313 false 2.281,0.979 2.448,0.313 false 2.01,1.677 2.135,1.198 false 2.479,1.677 2.281,1.198 false 1.833,0.104 2.146,0.292 0.313,0.188 10 false +B2 1.604,1.729 2.094,1.917 0.49,0.188 10 false GND2 2.396,1.729 2.885,1.917 0.49,0.188 10 false GND1 2.396,0.104 2.708,0.292 0.313,0.188 10 false +B 0.146,0.094 0.458,0.281 0.313,0.188 10 false *a 0.344,1.063 0.667,1.25 0.323,0.188 10 false A59

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A59-28 (GND1) - Body ground Power switch off Below 1 Ω
A59-27 (GND2) - Body ground Power switch off Below 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A59-10 (+B) - Body ground Power switch on (IG) 11 to 14 V
A59-9 (+B2) - Body ground Power switch on (IG) 11 to 14 V


NOTICE:

Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal.


i.

Reconnect the A59 inverter with converter assembly connector.



OK

15.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)

NG

REPAIR OR REPLACE POWER SOURCE CIRCUIT

15.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.

Disconnect the A22 power management control ECU connector.


d.

Measure the resistance according to the value(s) in the table below.

A398184E03
0.417,1.167 0.833,1.417 0.417,0.25 4.708,2.281 5.125,2.531 0.417,0.25 1.99,1.26 2.635,0.771 false 5.417,2.26 5.021,1.802 false 1.885,1.26 2.146,0.76 false 1.802,1.26 1.604,0.698 false 1.708,1.25 1.063,0.708 false 1.188,2 1.698,1.365 false 1.677,2.01 1.802,1.365 false 2.177,2 1.885,1.354 false 2.625,1.99 1.979,1.354 false 5.49,2.01 5.063,1.792 false 5.438,1.708 5.094,1.74 false 5.052,1.74 5.375,1.406 false 4.865,1.74 4.406,1.406 false 4.823,1.74 4.406,1.625 false 4.823,1.792 4.385,1.906 false 4.865,1.792 4.458,2.177 false 0.135,0.094 0.448,0.292 0.313,0.198 10 false *a 3.573,0.125 3.885,0.323 0.313,0.198 10 false *b 0.49,1.198 0.802,1.396 0.313,0.198 10 false A59 0.948,2.021 1.448,2.219 0.5,0.198 10 false CLK- 4.781,2.323 5.094,2.521 0.313,0.198 10 false A22 1.49,2.042 1.99,2.24 0.5,0.198 10 false REQ- 2.031,2.042 2.531,2.24 0.5,0.198 10 false MTH- 2.573,2.021 3.073,2.219 0.5,0.198 10 false HTM- 0.792,0.521 1.292,0.719 0.5,0.198 10 false CLK+ 5.49,1.625 5.99,1.823 0.5,0.198 10 false CLK- 1.385,0.521 1.885,0.719 0.5,0.198 10 false REQ+ 4.083,2.125 4.583,2.323 0.5,0.198 10 false REQ- 1.979,0.552 2.479,0.75 0.5,0.198 10 false MTH+ 5.542,1.948 6.042,2.146 0.5,0.198 10 false MTH- 2.542,0.583 3.042,0.781 0.5,0.198 10 false HTM+ 4.01,1.531 4.51,1.729 0.5,0.198 10 false HTM- 5.5,2.26 6,2.458 0.5,0.198 10 false MTH+ 5.448,1.323 5.948,1.521 0.5,0.198 10 false CLK+ 3.958,1.302 4.458,1.5 0.5,0.198 10 false HTM+ 3.958,1.833 4.458,2.031 0.5,0.198 10 false REQ+

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
A59-8 (HTM+) - A22-24 (HTM+) Power switch off Below 1 Ω
A59-18 (HTM-) - A22-25 (HTM-) Power switch off Below 1 Ω
A59-7 (MTH+) - A22-30 (MTH+) Power switch off Below 1 Ω
A59-17 (MTH-) - A22-29 (MTH-) Power switch off Below 1 Ω
A59-6 (REQ+) - A22-33 (REQ+) Power switch off Below 1 Ω
A59-16 (REQ-) - A22-32 (REQ-) Power switch off Below 1 Ω
A59-5 (CLK+) - A22-21 (CLK+) Power switch off Below 1 Ω
A59-15 (CLK-) - A22-20 (CLK-) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
A59-8 (HTM+) or A22-24 (HTM+) - Body ground and other terminals Power switch off 10 kΩ or higher
A59-18 (HTM-) or A22-25 (HTM-) - Body ground and other terminals Power switch off 10 kΩ or higher
A59-7 (MTH+) or A22-30 (MTH+) - Body ground and other terminals Power switch off 10 kΩ or higher
A59-17 (MTH-) or A22-29 (MTH-) - Body ground and other terminals Power switch off 10 kΩ or higher
A59-6 (REQ+) or A22-33 (REQ+) - Body ground and other terminals Power switch off 10 kΩ or higher
A59-16 (REQ-) or A22-32 (REQ-) - Body ground and other terminals Power switch off 10 kΩ or higher
A59-5 (CLK+) or A22-21 (CLK+) - Body ground and other terminals Power switch off 10 kΩ or higher
A59-15 (CLK-) or A22-20 (CLK-) - Body ground and other terminals Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
*b Rear view of wire harness connector
(to Power Management Control ECU)


e.

Connect the cable to the negative (-) auxiliary battery terminal.


f.

Turn the power switch on (IG).


g.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A59-8 (HTM+) or A22-24 (HTM+) - Body ground Power switch on (IG) Below 1 V
A59-18 (HTM-) or A22-25 (HTM-) - Body ground Power switch on (IG) Below 1 V
A59-7 (MTH+) or A22-30 (MTH+) - Body ground Power switch on (IG) Below 1 V
A59-17 (MTH-) or A22-29 (MTH-) - Body ground Power switch on (IG) Below 1 V
A59-6 (REQ+) or A22-33 (REQ+) - Body ground Power switch on (IG) Below 1 V
A59-16 (REQ-) or A22-32 (REQ-) - Body ground Power switch on (IG) Below 1 V
A59-5 (CLK+) or A22-21 (CLK+) - Body ground Power switch on (IG) Below 1 V
A59-15 (CLK-) or A22-20 (CLK-) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.



h.

Turn the power switch off.


i.

Disconnect the cable from the negative (-) auxiliary battery terminal.


j.

Reconnect the A22 power management control ECU connector.


k.

Reconnect the A59 inverter with converter assembly connector.



OK

16.CHECK POWER MANAGEMENT CONTROL ECU

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

16.CHECK POWER MANAGEMENT CONTROL ECU
a.

Disconnect the A22 power management control ECU connector.


b.
U154381E03
1.333,1.792 0.5,1.083 false 1.375,1.792 1.083,1.083 false 1.615,1.792 1.76,1.073 false 1.667,1.792 2.385,1.094 false 0.688,2.365 1.333,1.865 false 1.198,2.354 1.385,1.854 false 1.833,2.375 1.563,1.854 false 2.354,2.365 1.625,1.854 false 0.208,0.875 0.594,1.031 0.385,0.156 10 false HTM- 0.781,0.885 1.188,1.042 0.406,0.156 10 false HTM+ 1.615,0.885 2,1.042 0.385,0.156 10 false CLK+ 2.26,0.885 2.646,1.042 0.385,0.156 10 false CLK- 0.365,2.385 0.771,2.542 0.406,0.156 10 false REQ+ 0.938,2.375 1.344,2.531 0.406,0.156 10 false REQ- 1.615,2.396 2.021,2.552 0.406,0.156 10 false MTH+ 2.25,2.385 2.656,2.542 0.406,0.156 10 false MTH- 0.167,0.052 0.344,0.208 0.177,0.156 10 false *a 1.354,2.667 1.625,2.833 0.271,0.167 10 false A22

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A22-24 (HTM+) - A22-25 (HTM-) Power switch off 80 to 170 Ω
A22-30 (MTH+) - A22-29 (MTH-) Power switch off 80 to 170 Ω
A22-33 (REQ+) - A22-32 (REQ-) Power switch off 80 to 170 Ω
A22-21 (CLK+) - A22-20 (CLK-) Power switch off 80 to 170 Ω


Text in Illustration
*a Component without harness connected
(Power Management Control ECU)


c.

Reconnect the A22 power management control ECU connector.



OK

17.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)

NG

17.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)

OK

18.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)

NG

CONNECT SECURELY

18.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)

OK

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

CONNECT SECURELY

19.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)

OK

20.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR RESOLVER)

NG

CONNECT SECURELY

20.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR RESOLVER)

OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

NG

21.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)

OK

22.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR RESOLVER)

NG

CONNECT SECURELY

22.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR RESOLVER)

OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

NG

23.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.
U154308E02
1.938,0.396 2.115,0.99 false 2.542,0.385 2.271,0.99 false 1.729,0.198 2.042,0.375 0.313,0.177 10 false +B2 2.427,0.198 2.74,0.375 0.313,0.177 10 false +B 0.125,0.042 0.438,0.219 0.313,0.177 10 false *a 0.427,1.042 0.74,1.219 0.313,0.177 10 false A59

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A59-10 (+B) - Body ground Power switch off 10 kΩ or higher
A59-9 (+B2) - Body ground Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


d.

Reconnect the A59 inverter with converter assembly connector.



OK

24.REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

25.REPAIR OR REPLACE HARNESS OR CONNECTOR
24.REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS
a.

Refer to replace inverter with converter assembly parts (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DTC CHECK / CLEAR).



NEXT

REPLACE FUSE (PCU)

25.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (PCU)

26.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the inverter with converter assembly.


c.
A217462E06
1.604,0.042 1.771,0.208 0.167,0.167 10 false A 2.385,0.24 2.521,0.375 0.135,0.135 10 false A 0.917,1.594 1.052,1.76 0.135,0.167 10 true A 1.354,2.458 1.5,2.625 0.146,0.167 10 false B 1.188,2.656 1.333,2.833 0.146,0.177 10 true B 0.958,2.885 1.094,3.052 0.135,0.167 10 true B

Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

Specified Condition:
Bolt A:

T=20 N*m (204 kgf*cm, 15 ft.*lbf)

Bolt B:

T=10 N*m (102 kgf*cm, 7 ft.*lbf)


NOTICE:
·

Make sure that the tightening torque of the bolt A is between 16 and 24 N*m (163 and 245 kgf*cm, 12 and 18 ft.*lbf).

·

Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).




d.

Disconnect the generator cable from the hybrid vehicle transaxle assembly.


e.

Check for arc marks at the bolts and terminals for the generator cable.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



f.

Connect the generator cable to the hybrid vehicle transaxle assembly.


g.

Install the inverter with converter assembly.



A

27.CHECK GENERATOR CABLE

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

27.CHECK GENERATOR CABLE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the generator cable.


c.
U190584E02
1.323,1.813 1.063,1.927 false 1.729,1.823 1.729,1.917 false 2.156,1.813 2.365,1.938 false 1.427,4.146 1.26,4.354 false 1.781,4.146 1.76,4.354 false 2.135,4.146 2.271,4.354 false 0.917,1.115 0.76,1.24 false 2.417,3.073 2.604,2.99 false 0.135,0.083 0.333,0.25 0.198,0.167 10 false *1 0.552,1.198 0.708,1.354 0.156,0.156 10 false *3 0.135,2.406 0.375,2.604 0.24,0.198 10 false *2 0.958,1.948 1.115,2.104 0.156,0.156 10 false W 1.688,1.948 1.844,2.104 0.156,0.156 10 false U 2.385,1.948 2.542,2.104 0.156,0.156 10 false V 2.219,4.375 2.375,4.531 0.156,0.156 10 false W 1.719,4.375 1.885,4.563 0.167,0.188 10 false U 1.177,4.375 1.344,4.552 0.167,0.177 10 false V 2.656,2.885 2.823,3.063 0.167,0.177 10 false *3 2.802,1.177 2.979,1.333 0.177,0.156 10 false f1 2.813,3.458 3,3.646 0.188,0.188 10 false f2

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
f1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher


Text in Illustration
*1 Generator Cable
(Inverter with Converter Assembly Side)
*2 Generator Cable
(Hybrid Vehicle Transaxle Assembly Side)
*3 Shield ground

NOTICE:

Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground



d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
f1-1 (W) - f2-3 (W) Power switch off Below 1 Ω
f1-2 (U) - f2-2 (U) Power switch off Below 1 Ω
f1-3 (V) - f2-1 (V) Power switch off Below 1 Ω
f1-1 (W) - f2-2 (U) Power switch off 100 MΩ or higher
f1-2 (U) - f2-1 (V) Power switch off 100 MΩ or higher
f1-3 (V) - f2-3 (W) Power switch off 100 MΩ or higher



e.

Install the generator cable.



OK

NG

28.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A217463

Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

Specified Condition:

T=10 N*m (102 kgf*cm, 7 ft.*lbf)


NOTICE:

Make sure that the tightening torque of the bolts is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).



c.

Disconnect the motor cable from the hybrid vehicle transaxle assembly.


d.

Check for arc marks at the bolts and terminals for the motor cable.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



e.

Connect the motor cable to the hybrid vehicle transaxle assembly.



A

29.CHECK MOTOR CABLE

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

29.CHECK MOTOR CABLE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the motor cable.


c.
U190585E02
0.938,1.104 0.76,1.344 false 1.365,1.813 1.24,1.948 false 1.74,1.813 1.719,1.958 false 2.125,1.813 2.177,1.948 false 1.385,4.344 1.271,4.417 false 1.719,4.333 1.719,4.396 false 2.083,4.354 2.167,4.396 false 2.281,3.01 2.531,2.729 false 0.125,0.177 0.354,0.406 0.229,0.229 10 false *1 0.677,1.375 0.875,1.583 0.198,0.208 10 false *3 0.167,2.677 0.365,2.917 0.198,0.24 10 false *2 1.156,1.969 1.406,2.271 0.25,0.302 10 false W 2.146,1.979 2.354,2.188 0.208,0.208 10 false V 1.677,1.969 1.844,2.135 0.167,0.167 10 false U 2.146,4.417 2.365,4.594 0.219,0.177 10 false W 1.208,4.427 1.406,4.573 0.198,0.146 10 false U 1.677,4.417 1.844,4.583 0.167,0.167 10 false V 2.656,1.458 2.875,1.667 0.219,0.208 10 false e1 2.656,3.583 2.875,3.792 0.219,0.208 10 false e2 2.573,2.594 2.771,2.802 0.198,0.208 10 false *3

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
e1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher


Text in Illustration
*1 Motor Cable
(Inverter with Converter Assembly Side)
*2 Motor Cable
(Hybrid Vehicle Transaxle Assembly Side)
*3 Shield ground

NOTICE:

Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground



d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
e1-1 (W) - e2-1 (W) Power switch off Below 1 Ω
e1-2 (U) - e2-3 (U) Power switch off Below 1 Ω
e1-3 (V) - e2-2 (V) Power switch off Below 1 Ω
e1-1 (W) - e2-3 (U) Power switch off 100 MΩ or higher
e1-2 (U) - e2-2 (V) Power switch off 100 MΩ or higher
e1-3 (V) - e2-1 (W) Power switch off 100 MΩ or higher



e.

Install the motor cable.



OK

NG