Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.10–2014.11
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0AA6-526  Hybrid Battery Voltage System Isolation Fault  P0AA6-611  Hybrid Battery Voltage System Isolation Fault  P0AA6-612  Hybrid Battery Voltage System Isolation Fault  P0AA6-613  Hybrid Battery Voltage System Isolation Fault  P0AA6-614  Hybrid Battery Voltage System Isolation Fault  


DESCRIPTION

The power management control ECU monitors the battery smart unit and detects insulation malfunctions in the high-voltage system.

DTC No. INF Code DTC Detection Condition Trouble Area
P0AA6 526(*1) Insulation resistance between the high-voltage circuit and the body has decreased.*2
·

Hybrid vehicle transaxle assembly

·

Motor cable

·

Generator cable

·

Inverter with converter assembly

·

Frame wire

·

No. 2 engine wire

·

Hybrid battery junction block assembly

·

Air conditioning system

·

HV battery

·

Battery smart unit


611 Insulation resistance of the high voltage circuit in the air conditioning system has decreased.*3 Air conditioning system
612 Insulation resistance of the HV battery area has decreased.*3
·

Hybrid battery junction block assembly

·

Battery smart unit

·

HV battery


613 Insulation resistance of the transaxle area has decreased.*3
·

Hybrid vehicle transaxle assembly

·

Motor cable

·

Generator cable

·

Inverter with converter assembly


614 Insulation resistance of the high-voltage DC area has decreased.*3
·

Inverter with converter assembly

·

Frame wire

·

Air conditioning system

·

No. 2 engine wire

·

Hybrid battery junction block assembly



HINT:
·

*1: INF code 526 is stored together with P0AA6.

·

*2: The insulation malfunction detection circuit in the battery voltage sensor monitors the insulation resistance between the high voltage circuits and body. If the insulation resistance decreases, the power management control ECU stores DTC P0AA6-526 and illuminates the MIL first.

·

*3: If the following operations are performed within the same trip after DTC P0AA6-526 is stored, just one of the related DTCs (P0AA6-611, 612, 613 or 614) will be stored.

(a)

Apply the parking brake firmly.

(b)

Wait for 1 minute or more with the vehicle stopped, the brake pedal firmly depressed, the power switch on (READY), drive (D) selected and the air conditioning system on (Lo/COOL MAX, blower speed HI), then turn the power switch off and wait for 1 minute or more.


·

If DTC P0AA6 is stored, the vehicle cannot start.

·

When measuring insulation resistance using a megohmmeter, measure the resistance while jiggling the high voltage wire harness.



WIRING DIAGRAM

A256774E01
0.149,0.054 0.365,0.237 0.216,0.183 10 *a 3.477,7.493 3.693,7.676 0.216,0.183 10 *b 5.703,7.15 5.919,7.333 0.216,0.183 10 *c 1.243,6.383 1.459,6.566 0.216,0.183 10 *d 6.215,4.59 6.431,4.773 0.216,0.183 10 *e 3.527,7.15 3.743,7.333 0.216,0.183 10 *f 1.066,1.076 1.282,1.259 0.216,0.183 10 *1 1.825,3.131 2.041,3.314 0.216,0.183 10 *2 2.544,1.828 2.760,2.011 0.216,0.183 10 *3 2.544,3.911 2.760,4.094 0.216,0.183 10 *4 2.544,4.538 2.760,4.721 0.216,0.183 10 *5 2.914,4.678 3.131,4.861 0.216,0.183 10 *6 0.464,2.998 0.680,3.181 0.216,0.183 10 *7 3.738,1.09 3.954,1.273 0.216,0.183 10 *8 4.429,2.115 4.645,2.298 0.216,0.183 10 *9 5.252,3.138 5.559,3.321 0.307,0.183 10 *10 6.239,2.754 6.546,2.937 0.307,0.183 10 *11 6.239,3.598 6.546,3.781 0.307,0.183 10 *12 4.161,5.344 4.469,5.527 0.307,0.183 10 *13 4.44,6.133 4.747,6.316 0.307,0.183 10 *14 5.746,6.149 6.053,6.332 0.307,0.183 10 *15

Text in Illustration
*1 HV Battery *2 Battery Smart Unit
*3 SMRB *4 SMRG
*5 SMRP *6 System Main Resistor
*7 Service Plug Grip *8 Inverter with Converter Assembly
*9 Boost Converter *10 Inverter
*11 MG1 *12 MG2
*13 Compressor with Motor Assembly *14 A/C Inverter
*15 A/C Motor - -
*a High-voltage Areas *b INF Code 526 Vehicle Insulation Resistance Reduction Area
*c INF Code 611 Air Conditioning System Area *d INF Code 612 HV Battery Area
*e INF Code 613 Transaxle Area *f INF Code 614 High Voltage Direct Current Area

SYSTEM DESCRIPTION

HINT:

If a decrease in insulation resistance cannot be confirmed using a megohmmeter, check the Short Wave Highest Val in the Data List.


Characteristics of Short Wave Highest Value


a.

The Data List item Short Wave Highest Val and insulation resistance have the relationship shown in the table below. Short Wave Highest Val decreases with a decrease in insulation resistance. However, in some cases, even though the insulation resistance of the vehicle is normal, Short Wave Highest Val may decrease. Therefore, check Short Wave Highest Val while considering the following.

·

Do not check until approximately 1 minute has passed after the power switch is turned on (IG) (*1).

·

Do not check when there is a difference between the system voltages (Power Resource VB, VL-Voltage before Boosting, and VH-Voltage after Boosting) (*2).

Short Wave Highest Value Trouble Area
Neither condition (*1) nor (*2) is met and Short Wave Highest Val is approximately 0 V Since the insulation resistance is close to 0 Ω, there is a strong possibility of interference with a metal object.
Neither condition (*1) nor (*2) is met and Short Wave Highest Val is between 0 and 5 V Since the insulation resistance is several hundred kiloohms, there is a strong possibility of the presence of fluid such as coolant.




How to Determine Part with Insulation Malfunction


a.

Jiggle the high-voltage wire harness to check if the resistance to body ground changes with the position of the wire harness or force applied.


b.

Repeat rotating and stopping of the MG1, MG2 and compressor with motor assembly. Check that the Short Wave Highest Val does not decrease (for example if the motor stops with foreign matter forming a leak path) when the motor stops, or that the Short Wave Highest Val does not return to normal (for example if foreign matter moves away from the leak path) when the motor rotates.


c.

Increase the temperature of MG1and MG2. Check if the Short Wave Highest Val decreases with the temperature increase.


d.

Check that the transaxle fluid is not cloudy and the coolant level in the reserve tank has not dropped as the transaxle fluid will become cloudy when mixed with coolant, resulting in low insulation resistance.



Confirmation After Replacing Parts


a.

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output. (Do not turn the power switch off during this inspection.)

i.

Apply the parking brake and secure the wheels using chocks.


ii.

With the vehicle stationary, turn the power switch on (READY) with park (P) selected and wait for 60 seconds or more.


iii.

Turn the air conditioning system on (MAX COLD, blower speed HI).


iv.

While depressing the brake pedal without depressing the accelerator pedal, move the shift lever to D and wait for 5 minutes.

·

If step A is performed within the same trip after DTC P0AA6-526 is stored, the parts with insufficient insulation resistance will be determined, and a DTC (P0AA6-611, 612, 613 or 614) will be stored.

·

If no DTCs are output, proceed to the next step.



v.

Drive the vehicle for approximately 5 minutes referring to the following freeze frame data items: "Vehicle Spd", "Shift Sensor Shift Pos", "Accel Pedal Pos #1", "Engine Revolution", "Engine Coolant Temp" and "Master Cylinder Ctrl Trq" (If the freeze frame data item "Vehicle Spd" is 6 mph (10 km/h) or less, drive the vehicle at 6 mph (10 km/h) or more.).

·

If step A is performed within the same trip after DTC P0AA6-526 is stored, the parts with insufficient insulation resistance will be determined, and a DTC (P0AA6-611, 612, 613 or 614) will be stored.

·

If no DTCs are output, insulation fault does not detected.



vi.

Wait for 1 minute or more with the vehicle stopped, the power switch on (READY), the shift lever in P and the air conditioning system on (Lo/COOL MAX, blower speed HI), then turn the power switch off and wait for 1 minute or more. (Step A)




CAUTION / NOTICE / HINT

CAUTION:
·

When performing P0AA6 troubleshooting, use either a tool wrapped with vinyl insulation tape or a insulated tool. (It is extremely dangerous when a high-voltage charge passes through a non-insulated tool causing a short.)

·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

When measuring insulation resistance using a megohmmeter, set the megohmmeter to 500 V.


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

Result:
Result Proceed to
P0AA6 only is output. A
P0AA6 and P0A1D (power management control ECU malfunction) are output. B
P0AA6 and P0AA7 (malfunction in the battery smart unit) are output. C
P0AA6 and P0AFC (Hybrid Battery Pack Sensor Module) are output. D



e.

Turn the power switch off.



A

2.CHECK INFORMATION CODE

B

C

D

2.CHECK INFORMATION CODE
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Access the freeze frame data of DTC P0AA6 and read the INF code.

NOTICE:
·

Information codes 611, 612, 613 and 614 are not stored with 526 simultaneously. If a drop in insulation resistance is detected and DTC P0AA6-526 is output, wait for 1 minute with power switch on (READY), drive (D) selected and the air conditioning system on within the same trip, then turn the power switch off and wait for 1 minute to determine the information code (611, 612, 613 or 614).

·

If only DTC P0AA6-526 is output, perform the diagnosis procedure for INF code 526 to inspect all the high voltage circuits.



Result:
Result Proceed to
526 (decrease in the insulation resistance of the high-voltage circuit) only is output A
526 and 611 (decrease in the insulation resistance of the air conditioning system area) are output Refer to the troubleshooting procedures for P0AA6-611 (Air conditioning system) (See page (Click here))
526 and 612 (decrease in the insulation resistance of the battery area) are output B
526 and 613 (decrease in the insulation resistance of the transaxle area) are output C
526 and 614 (decrease in the insulation resistance of the high-voltage DC area) are output D



e.

Turn the power switch off.



A

3.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE)

B

8.CHECK HV BATTERY AREA

C

10.CHECK INVERTER WITH CONVERTER ASSEMBLY

D

11.CHECK HIGH VOLTAGE DIRECT CURRENT AREA
3.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.

HINT:

Make sure that no foreign matter has entered or contaminated the inverter with converter assembly.



c.
U190699E02
1.823,0.333 1.677,0.125 1.677,0.125 1.271,0.125 true 1.521,0.615 1.375,0.406 1.375,0.406 0.969,0.406 true 2.417,0.563 2.583,0.74 0.167,0.177 10 false e1 2.094,1 2.281,1.177 0.188,0.177 10 false f1 1.104,0.042 1.271,0.208 0.167,0.167 10 true *1 0.792,0.323 0.958,0.49 0.167,0.167 10 true *2

Disconnect the motor cable e1 and generator cable f1 from the inverter with converter assembly.

Text in Illustration
*1 Motor Cable
*2 Generator Cable


d.

Connect the cable to the negative (-) auxiliary battery terminal.

HINT:

As the insulation resistance may vary when motor (MG2) rotates, perform this inspection while rotating the front wheels.



e.

Turn the power switch on (IG).

NOTICE:

Turning the power switch on (IG) with the service grip removed causes DTCs to be stored. Clear the DTCs after performing this inspection.



f.

With the neutral (N) selected and lift up the vehicle.


g.
U190552E02
0.969,1.021 0.625,1.031 false 1.354,1.771 1.229,1.969 false 1.719,1.771 1.719,1.958 false 2.125,1.781 2.229,1.979 false 0.083,0.083 0.26,0.26 0.177,0.177 10 false *1 0.396,0.969 0.573,1.146 0.177,0.177 10 false *2 1.135,1.969 1.313,2.146 0.177,0.177 10 false W 1.688,1.969 1.875,2.146 0.188,0.177 10 false U 2.208,1.969 2.385,2.146 0.177,0.177 10 false V 2.823,1.042 3.094,1.208 0.271,0.167 10 false e1

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below while rotating the front wheels 2 revolutions in the same direction simultaneously.

NOTICE:
·

Carefully perform this inspection as motor (MG2) may generate current when the front wheels are rotated by hand.

·

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.



Standard Resistance:
Tester Connection Condition Specified Condition
e1-3 (V) - Body ground and shield ground Power switch on 100 MΩ or higher
e1-2 (U) - Body ground and shield ground Power switch on 100 MΩ or higher
e1-1 (W) - Body ground and shield ground Power switch on 100 MΩ or higher


Text in Illustration
*1 Motor Cable
(Inverter with Converter Assembly Side)
*2 Shield Ground


h.

Lower the vehicle and push the P position switch.


i.

Turn the power switch off.


j.

Disconnect the cable from the negative (-) auxiliary battery terminal.



OK

4.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE)

NG

16.CHECK MOTOR CABLE
4.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Connect the cable to the negative (-) auxiliary battery terminal.

HINT:

As the insulation resistance may vary when generator (MG1) rotates, perform this inspection while rotating the front wheels.



c.

Turn the power switch on (IG).

NOTICE:

Turning the power switch on (IG) with the service grip removed causes DTCs to be stored. Clear the DTCs after performing this inspection.



d.

With the neutral (N) selected and lift up the vehicle.


e.
U190549E02
0.948,1.031 0.594,1.031 false 1.333,1.792 1.208,1.958 false 1.75,1.823 1.75,1.948 false 2.146,1.802 2.292,1.969 false 0.073,0.094 0.281,0.323 0.208,0.229 10 false *1 0.396,0.958 0.604,1.188 0.208,0.229 10 false *2 1.115,1.969 1.323,2.135 0.208,0.167 10 false W 1.708,1.969 1.854,2.125 0.146,0.156 10 false U 2.25,1.958 2.458,2.125 0.208,0.167 10 false V 2.823,1.094 2.958,1.26 0.135,0.167 10 false f1

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below while rotating the front wheels 2 revolutions in the same direction simultaneously.

NOTICE:
·

Carefully perform this inspection as generator (MG1) may generate current when the front wheels are rotated by hand.

·

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.



Standard Resistance:
Tester Connection Condition Specified Condition
f1-3 (V) - Body ground and shield ground Power switch on 100 MΩ or higher
f1-2 (U) - Body ground and shield ground Power switch on 100 MΩ or higher
f1-1 (W) - Body ground and shield ground Power switch on 100 MΩ or higher


Text in Illustration
*1 Generator Cable
(Inverter with Converter Assembly Side)
*2 Shield Ground


f.

Lower the vehicle and push the P position switch.


g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal.



OK

5.CHECK NO. 2 ENGINE WIRE

NG

17.CHECK GENERATOR CABLE
5.CHECK NO. 2 ENGINE WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
U190700E02
1.031,1.646 1.292,1.865 0.26,0.219 10 false E3

Disconnect the No. 2 engine wire (air conditioning harness) E3 from the inverter with converter assembly.

HINT:

Make sure that no foreign matter has entered or contaminated the connector of the No. 2 engine wire (air conditioning harness) E3.



c.
U190554E02
2.625,0.563 3.125,0.563 false 1.813,1.229 1.813,1.802 true 1.417,1.229 1.063,1.583 true 0.073,0.083 0.25,0.25 0.177,0.167 10 false *1 3.156,0.479 3.333,0.646 0.177,0.167 10 false *2 0.833,1.604 1.281,1.771 0.448,0.167 10 false ACPB 1.573,1.823 2.021,1.99 0.448,0.167 10 false ACPE 0.469,1.083 0.729,1.26 0.26,0.177 10 false E3

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
E3-1 (ACPB) - Body ground and shield ground Power switch off 3 MΩ or higher
E3-2 (ACPE) - Body ground and shield ground Power switch off 3 MΩ or higher


Text in Illustration
*1 No. 2 Engine Wire (Air Conditioning Harness)
(Inverter with Converter Assembly Side)
*2 Shield Ground



OK

6.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

13.CHECK NO. 2 ENGINE WIRE
6.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
U154445E02
0.688,1.115 0.885,1.292 0.198,0.177 10 false T1

Disconnect the frame wire T1 from the inverter with converter assembly.

HINT:

Make sure that no foreign matter has entered or contaminated the connector of the frame wire T1.



c.
A379087

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
High voltage terminal - Body ground Power switch off 1 MΩ or higher


HINT:

Perform this inspection with the motor cable, generator cable and No. 2 engine wire (air conditioning harness) disconnected from the inverter with converter assembly.




OK

7.CHECK FRAME WIRE

NG

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

7.CHECK FRAME WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
U190556E02
1.229,1.76 0.677,1.833 false 2.063,1.76 2.698,1.833 false 2.427,0.875 2.906,0.521 false 0.104,0.094 0.292,0.26 0.188,0.167 10 false *1 0.406,1.76 0.688,1.958 0.281,0.198 10 false CEI 2.729,1.76 3.01,1.958 0.281,0.198 10 false CBI 2.906,1.063 3.167,1.24 0.26,0.177 10 false T1 2.948,0.406 3.135,0.573 0.188,0.167 10 false *2

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
T1-1 (CEI) - Body ground and shield ground Power switch off 10 MΩ or higher
T1-2 (CBI) - Body ground and shield ground Power switch off 10 MΩ or higher


Text in Illustration
*1 Frame Wire
(Inverter with Converter Assembly Side)
*2 Shield Ground

HINT:

Visually inspect the frame wire for damage. If there is any damage, then this is the likely cause of low insulation resistance.




OK

8.CHECK HV BATTERY AREA

NG

14.CHECK FRAME WIRE
8.CHECK HV BATTERY AREA
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


c.

2012/05 - 2013/12:

i.
U190637E02
0.26,0.885 0.521,1.042 0.26,0.156 10 false z23 0.583,0.708 0.844,0.865 0.26,0.156 10 false z22 0.927,0.563 1.188,0.719 0.26,0.156 10 false z27 1.292,0.438 1.552,0.594 0.26,0.156 10 false z26

Disconnect the z22, z23, z27 and z26 battery smart unit connectors.



d.

2013/12 -:

i.
U190638E02
0.25,0.885 0.51,1.042 0.26,0.156 10 false z31 0.583,0.719 0.844,0.875 0.26,0.156 10 false z30 0.917,0.563 1.177,0.719 0.26,0.156 10 false z33 1.292,0.448 1.552,0.604 0.26,0.156 10 false z32

Disconnect the z30, z31, z32 and z33 battery smart unit connectors.



e.
A251527E02
1.396,0.667 1.229,1.458 false 2.458,0.708 2.74,1.479 false 2.708,1.49 2.844,1.656 0.135,0.167 10 false 1 1.167,1.479 1.333,1.688 0.167,0.208 10 true 2

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
1 - Body ground Power switch off 10 MΩ or higher
2 - Body ground Power switch off 10 MΩ or higher




OK

9.CHECK HV BATTERY

NG

15.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
9.CHECK HV BATTERY
a.

Check that no electrolyte is leaking from each HV battery stack (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>INSPECTION).


Result:
Result Proceed to
Electrolyte is not leaking from the HV battery stack. A
Electrolyte is leaking from the HV battery stack. B



A

B

10.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.

HINT:

Make sure that no foreign matter has entered or contaminated the inverter with converter assembly.



c.
U190699E02
1.823,0.333 1.677,0.125 1.677,0.125 1.271,0.125 true 1.521,0.615 1.375,0.406 1.375,0.406 0.969,0.406 true 2.417,0.563 2.583,0.74 0.167,0.177 10 false e1 2.094,1 2.281,1.177 0.188,0.177 10 false f1 1.104,0.042 1.271,0.208 0.167,0.167 10 true *1 0.792,0.323 0.958,0.49 0.167,0.167 10 true *2

Disconnect the motor cable e1 and generator cable f1 from the inverter with converter assembly.

Text in Illustration
*1 Motor Cable
*2 Generator Cable


d.
A379088

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
High voltage terminal - Body ground Power switch off 1 MΩ or higher


Result:
Result Proceed to
NG A
OK B




A

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

B

18.CHECK MOTOR CABLE
11.CHECK HIGH VOLTAGE DIRECT CURRENT AREA
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.

HINT:

Make sure that no foreign matter has entered or contaminated the inverter with converter assembly.



c.
U154447E03
0.719,1.115 0.917,1.292 0.198,0.177 10 false T1

Disconnect the frame wire T1 from the inverter with converter assembly.

HINT:

Make sure that no foreign matter has entered or contaminated the connector of the frame wire T1.



d.
U190556E02
1.229,1.76 0.677,1.833 false 2.063,1.76 2.698,1.833 false 2.427,0.875 2.906,0.521 false 0.104,0.094 0.292,0.26 0.188,0.167 10 false *1 0.406,1.76 0.688,1.958 0.281,0.198 10 false CEI 2.729,1.76 3.01,1.958 0.281,0.198 10 false CBI 2.906,1.063 3.167,1.24 0.26,0.177 10 false T1 2.948,0.406 3.135,0.573 0.188,0.167 10 false *2

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
T1-1 (CEI) - Body ground and shield ground Power switch off 10 MΩ or higher
T1-2 (CBI) - Body ground and shield ground Power switch off 10 MΩ or higher


Text in Illustration
*1 Frame Wire
(Inverter with Converter Assembly Side)
*2 Shield Ground

HINT:

Visually inspect the frame wire for damage. If there is any damage, then this is the likely cause of low insulation resistance.




OK

12.CHECK NO. 2 ENGINE WIRE

NG

14.CHECK FRAME WIRE
12.CHECK NO. 2 ENGINE WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
U190712E02
1.094,1.635 1.292,1.844 0.198,0.208 10 false E3

Disconnect the No. 2 engine wire (air conditioning harness) E3 from the inverter with converter assembly.


c.
U190554E02
2.625,0.563 3.125,0.563 false 1.813,1.229 1.813,1.802 true 1.417,1.229 1.063,1.583 true 0.073,0.083 0.25,0.25 0.177,0.167 10 false *1 3.156,0.479 3.333,0.646 0.177,0.167 10 false *2 0.833,1.604 1.281,1.771 0.448,0.167 10 false ACPB 1.573,1.823 2.021,1.99 0.448,0.167 10 false ACPE 0.469,1.083 0.729,1.26 0.26,0.177 10 false E3

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
E3-1 (ACPB) - Body ground and shield ground Power switch off 3 MΩ or higher
E3-2 (ACPE) - Body ground and shield ground Power switch off 3 MΩ or higher


Text in Illustration
*1 No. 2 Engine Wire (Air Conditioning Harness)
(Inverter with Converter Assembly Side)
*2 Shield Ground



OK

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

13.CHECK NO. 2 ENGINE WIRE
13.CHECK NO. 2 ENGINE WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
U110637E04
2.802,0.719 3.031,0.344 false 1.177,2.198 1.365,2.375 0.188,0.177 10 false E1 3.031,0.167 3.219,0.375 0.188,0.208 10 false *1

Disconnect the No. 2 engine wire (air conditioning harness) E1 from the compressor with motor assembly.

Text in Illustration
*1 Green Lock


c.
U190554E02
2.625,0.563 3.125,0.563 false 1.813,1.229 1.813,1.802 true 1.417,1.229 1.063,1.583 true 0.073,0.083 0.25,0.25 0.177,0.167 10 false *1 3.156,0.479 3.333,0.646 0.177,0.167 10 false *2 0.833,1.604 1.281,1.771 0.448,0.167 10 false ACPB 1.573,1.823 2.021,1.99 0.448,0.167 10 false ACPE 0.469,1.083 0.729,1.26 0.26,0.177 10 false E3

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
E3-1 (ACPB) - Body ground and shield ground Power switch off 10 MΩ or higher
E3-2 (ACPE) - Body ground and shield ground Power switch off 10 MΩ or higher


Text in Illustration
*1 No. 2 Engine Wire (Air Conditioning Harness)
(Inverter with Converter Assembly Side)
*2 Shield Ground



OK

GO TO AIR CONDITIONING SYSTEM (P0AA6-611)

NG

REPLACE NO. 2 ENGINE WIRE

14.CHECK FRAME WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


c.
A252586

Disconnect the frame wire from the hybrid battery junction block assembly.


d.
U190656E02
2.042,1.813 2.594,1.396 false 1.771,1.083 2.031,1.24 0.26,0.156 10 false T5 2.292,0.333 2.552,0.49 0.26,0.156 10 false T6 1.844,1.75 2.073,1.958 0.229,0.208 10 true *1

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
T6-1 (CBI) - Body ground and shield ground Power switch off 10 MΩ or higher
T5-1 (CEI) - Body ground and shield ground Power switch off 10 MΩ or higher


Text in Illustration
*1 Shield Ground

HINT:

Visually inspect the frame wire for damage. If there is any damage, then this is the likely cause of low insulation resistance.




OK

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

NG

15.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
U190639E02
1.552,0.458 1.813,0.667 0.26,0.208 10 false k3 0.865,1.958 1.156,2.156 0.292,0.198 10 false h3

Disconnect the high voltage cable connector of the HV battery k3 and h3 from the hybrid battery junction block assembly.


c.
U190641E02
1.021,0.719 1.281,0.875 0.26,0.156 10 false k3 0.354,1.198 0.615,1.354 0.26,0.156 10 false h3

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
h3-1 (-) - Hybrid Battery Carrier Panel Power switch off 10 MΩ or higher
k3-1 (+) - Hybrid Battery Carrier Panel Power switch off 10 MΩ or higher




OK

NG

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

16.CHECK MOTOR CABLE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the motor cable from the hybrid vehicle transaxle assembly (See page Drivetrain>P410 (HYBRID TRANSMISSION / TRANSAXLE)>MOTOR CABLE>COMPONENTS).


c.
U190552E02
0.969,1.021 0.625,1.031 false 1.354,1.771 1.229,1.969 false 1.719,1.771 1.719,1.958 false 2.125,1.781 2.229,1.979 false 0.083,0.083 0.26,0.26 0.177,0.177 10 false *1 0.396,0.969 0.573,1.146 0.177,0.177 10 false *2 1.135,1.969 1.313,2.146 0.177,0.177 10 false W 1.688,1.969 1.875,2.146 0.188,0.177 10 false U 2.208,1.969 2.385,2.146 0.177,0.177 10 false V 2.823,1.042 3.094,1.208 0.271,0.167 10 false e1

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
e1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher


Text in Illustration
*1 Motor Cable
(Inverter with Converter Assembly Side)
*2 Shield Ground



OK

NG

17.CHECK GENERATOR CABLE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the generator cable from the hybrid vehicle transaxle assembly (See page Drivetrain>P410 (HYBRID TRANSMISSION / TRANSAXLE)>GENERATOR CABLE>COMPONENTS).


c.
U190549E02
0.948,1.031 0.594,1.031 false 1.333,1.792 1.208,1.958 false 1.75,1.823 1.75,1.948 false 2.146,1.802 2.292,1.969 false 0.073,0.094 0.281,0.323 0.208,0.229 10 false *1 0.396,0.958 0.604,1.188 0.208,0.229 10 false *2 1.115,1.969 1.323,2.135 0.208,0.167 10 false W 1.708,1.969 1.854,2.125 0.146,0.156 10 false U 2.25,1.958 2.458,2.125 0.208,0.167 10 false V 2.823,1.094 2.958,1.26 0.135,0.167 10 false f1

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
f1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher


Text in Illustration
*1 Generator Cable
(Inverter with Converter Assembly Side)
*2 Shield Ground



OK

NG

18.CHECK MOTOR CABLE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the motor cable from the hybrid vehicle transaxle assembly (See page Drivetrain>P410 (HYBRID TRANSMISSION / TRANSAXLE)>MOTOR CABLE>COMPONENTS).


c.
U190552E02
0.969,1.021 0.625,1.031 false 1.354,1.771 1.229,1.969 false 1.719,1.771 1.719,1.958 false 2.125,1.781 2.229,1.979 false 0.083,0.083 0.26,0.26 0.177,0.177 10 false *1 0.396,0.969 0.573,1.146 0.177,0.177 10 false *2 1.135,1.969 1.313,2.146 0.177,0.177 10 false W 1.688,1.969 1.875,2.146 0.188,0.177 10 false U 2.208,1.969 2.385,2.146 0.177,0.177 10 false V 2.823,1.042 3.094,1.208 0.271,0.167 10 false e1

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
e1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher


Text in Illustration
*1 Motor Cable
(Inverter with Converter Assembly Side)
*2 Shield Ground



OK

19.CHECK GENERATOR CABLE

NG

19.CHECK GENERATOR CABLE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the generator cable from the hybrid vehicle transaxle assembly (See page Drivetrain>P410 (HYBRID TRANSMISSION / TRANSAXLE)>GENERATOR CABLE>COMPONENTS).


c.
U190549E02
0.948,1.031 0.594,1.031 false 1.333,1.792 1.208,1.958 false 1.75,1.823 1.75,1.948 false 2.146,1.802 2.292,1.969 false 0.073,0.094 0.281,0.323 0.208,0.229 10 false *1 0.396,0.958 0.604,1.188 0.208,0.229 10 false *2 1.115,1.969 1.323,2.135 0.208,0.167 10 false W 1.708,1.969 1.854,2.125 0.146,0.156 10 false U 2.25,1.958 2.458,2.125 0.208,0.167 10 false V 2.823,1.094 2.958,1.26 0.135,0.167 10 false f1

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
f1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher


Text in Illustration
*1 Generator Cable
(Inverter with Converter Assembly Side)
*2 Shield Ground



OK

NG