Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.03–2012.10
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P3004-131  High Voltage Power Resource  


DESCRIPTION

Refer to the description for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).

The power management control ECU monitors the high-voltage wiring between the HV battery and the inverter with converter assembly and detects the following malfunction.

DTC No. INF Code DTC Detection Condition Trouble Area
P3004 131 One of the following occurs during pre-charge (the time from when SMRP turns on until SMRG turns on):
·

Electric battery fuse in the service plug grip has an open circuit

·

Service plug grip is not installed

·

SMRP remains open

·

SMRB remains open

·

Precharge resistor has an open circuit

·

High voltage cable has an open circuit


·

Hybrid battery junction block assembly

·

Frame wire

·

Inverter with converter assembly

·

HV battery

·

Wire harness or connector



WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).


CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

After the repair, clear the DTCs, perform the following procedure and check that the same DTC (including pending DTC) is not output.

1.

Turn the power switch off and wait for 30 seconds or more.

2.

Turn the power switch on (READY) and wait for 30 seconds or more.



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

Result:
Result Proceed to
DTC P3004-131 only is output, or DTC other than the one in the table below is also output. A
Following DTC is also output. B


DTC No. Relevant Diagnosis
P31AB-123 Hybrid Battery Cell Low Voltage

HINT:

P3004-131 may be output due to a malfunction which causes the DTC in the table above to be output. In this case, first troubleshoot the output DTC in the table above. Then, perform a reproduction test to check that no DTCs are output.



e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

Result:
Result Proceed to
DTC P3004-131 only is output, or DTCs other than the ones in the table below are also output. A
DTCs shown in Table 1 are output simultaneously. B
DTCs shown in Table 2 are output simultaneously. C


Table 1
DTC No. Relevant Diagnosis
P0A1A-151, 155, 156, 658, 659 Generator Control Module
P0A1B-164, 193, 512, 661, 786 Drive Motor "A" Control Module
P0A1D-148 Hybrid Powertrain Control Module
P0A78-266, 267, 586 Drive Motor "A" Inverter Performance
P0A94-442 DC / DC Converter Performance
P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
P0AE6-225 Hybrid Battery Precharge Contactor Control Circuit Low
P0AE7-224 Hybrid Battery Precharge Contactor Control Circuit High
P0C76-523 Hybrid Battery System Discharge Time Too Long
P2511-149 HV CPU Power Relay Sensor Circuit Intermittent No Continuity
P3004-800, 801 High Voltage Power Resource
P324E-788 MG-ECU Power Relay Intermittent Circuit
U0110 (all INF codes)*1 Lost Communication with Drive Motor Control Module "A"

Table 2
DTC No. Relevant Diagnosis
P0A95-123 High Voltage Fuse
P0ABF-123 Hybrid Battery Pack Current Sensor Circuit
P0AC0-123 Hybrid Battery Pack Current Sensor Circuit Range / Performance
P0AC1-123 Hybrid Battery Pack Current Sensor "A" Circuit Low
P0AC2-123 Hybrid Battery Pack Current Sensor "A" Circuit High
P0AFC-123 Hybrid Battery Pack Sensor Module
P0B3D-123 Hybrid Battery Voltage Sensor "A" Circuit Low
P0B42-123 Hybrid Battery Voltage Sensor "B" Circuit Low
P0B47-123 Hybrid Battery Voltage Sensor "C" Circuit Low
P0B4C-123 Hybrid Battery Voltage Sensor "D" Circuit Low
P0B51-123 Hybrid Battery Voltage Sensor "E" Circuit Low
P0B56-123 Hybrid Battery Voltage Sensor "F" Circuit Low
P0B5B-123 Hybrid Battery Voltage Sensor "G" Circuit Low
P0B60-123 Hybrid Battery Voltage Sensor "H" Circuit Low
P0B65-123 Hybrid Battery Voltage Sensor "I" Circuit Low
P308A-123 Hybrid Battery Voltage Sensor All Circuits Low
U029A-123 Lost Communication with Hybrid Battery Pack Sensor Module

HINT:
·

*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

·

P3004-131 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.




e.

Turn the power switch off.



A

3.CHECK FREEZE FRAME DATA (HYBRID CONTROL)

B

C

3.CHECK FREEZE FRAME DATA (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Read the freeze frame data of DTC P3004-131.

Result:
Result Proceed to
Both of the following conditions are met:
·

"VH-Voltage after Boosting" is below 50 V.

·

Difference between "Power Resource VB" and "VL-Voltage before Boosting" is 50 V or less.


A
Other than above B



e.

Turn the power switch off.



A

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

B

4.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)
4.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

5.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY SIDE)

NG

CONNECT SECURELY

5.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY SIDE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.


c.
U190701E02
0.708,1.177 0.906,1.354 0.198,0.177 10 false T1 0.708,0.917 0.875,1.083 0.167,0.167 10 true B 1.26,0.333 1.427,0.51 0.167,0.177 10 true B 1.76,0.833 1.917,1.021 0.156,0.188 10 true A 1.615,1.313 1.76,1.51 0.146,0.198 10 true A

Check the connection between the frame wire T1 and the inverter with converter assembly.

Specified Condition:
Bolt A:

8.0 N*m (82 kgf*cm, 71 in.*lbf)

Bolt B:

9.2 N*m (94 kgf*cm, 81 ft.*lbf)



d.

Check for arc marks on the terminals of the frame wire.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



e.

Install the inverter cover to the inverter with converter assembly.



A

6.CHECK FRAME WIRE (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY SIDE)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

6.CHECK FRAME WIRE (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY SIDE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


c.
U190693E02
1.708,1.104 1.969,1.26 0.26,0.156 10 false T6 1.698,1.719 1.958,1.875 0.26,0.156 10 false T5

Check the connection between the frame wire T5, T6 and the hybrid battery junction block assembly.


Specified Condition:

9.0 N*m (92 kgf*cm, 80 in.*lbf)


d.

Check for arc marks on the terminals of the frame wire.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



e.

Install the No. 2 hybrid battery shield sub-assembly.



A

7.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

7.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.


c.
U154448E02
0.719,1.104 0.917,1.281 0.198,0.177 10 false T1

Disconnect the frame wire T1 from the inverter with converter assembly.


d.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


e.
U190690E02
2.146,1.833 2.396,1.833 false 1.052,1.833 1.302,1.833 false 0.177,0.104 0.417,0.292 0.24,0.188 10 false *1 0.177,2.177 0.417,2.365 0.24,0.188 10 false *2 2.427,1.76 2.76,1.948 0.333,0.188 10 false CBI 0.771,1.75 1.063,1.938 0.292,0.188 10 false CEI 1.75,4.156 2.01,4.333 0.26,0.177 10 false T5 1.667,3.479 1.927,3.656 0.26,0.177 10 false T6 0.479,1.063 0.74,1.24 0.26,0.177 10 false T1

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T6-1 (CBI) - T1-2 (CBI) Power switch off Below 1 Ω
T5-1 (CEI) - T1-1 (CEI) Power switch off Below 1 Ω


Text in Illustration
*1 Frame Wire
(Inverter with Converter Assembly Side)
*2 Frame Wire
(Hybrid Battery Junction Block Assembly)


f.

Install the No. 2 hybrid battery shield sub-assembly.


g.

Connect the frame wire to the inverter with converter assembly.


h.

Install the inverter cover to the inverter with converter assembly.



OK

8.CHECK CONNECTOR CONNECTION CONDITION (HV BATTERY HIGH VOLTAGE CONNECTOR)

NG

8.CHECK CONNECTOR CONNECTION CONDITION (HV BATTERY HIGH VOLTAGE CONNECTOR)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


c.
U190640E02
1.521,0.469 1.781,0.625 0.26,0.156 10 false k3 0.844,1.948 1.104,2.104 0.26,0.156 10 false h3

Check the connections between the HV battery high voltage connectors (k3, h3) and the hybrid battery junction block assembly.

OK:

The connectors are connected securely and not damaged.



d.

Check for arc marks on the terminals of the HV battery high voltage connectors.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



e.

Install the No. 2 hybrid battery shield sub-assembly.



A

9.CHECK HV BATTERY

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

9.CHECK HV BATTERY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


c.
U190696E02
1.188,1.792 1.406,1.99 0.219,0.198 10 false h3 1.531,1.365 1.74,1.563 0.208,0.198 10 false k3 1.885,1.438 2.073,1.635 0.188,0.198 10 true 1 2.563,1.479 2.781,1.677 0.219,0.198 10 true 2

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
k3-1 (+) - 1 Power switch off 84 V or higher
h3-1 (-) - 2 Power switch off 84 V or higher


CAUTION:

Do not allow the probes of the electrical tester to contact each other during this inspection.



d.

Install the No. 2 hybrid battery shield sub-assembly.



OK

10.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

NG

10.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the L5 power management control ECU connector.


c.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


d.

Disconnect the c6 hybrid battery junction block assembly connector.

HINT:

Before disconnecting the connector c6 that drives the system main relay of the hybrid battery junction block assembly, make sure that the connector is securely engaged.



e.

Measure the resistance according to the value(s) in the table below.

A317802E16
2.917,1.667 3.271,1.917 0.354,0.25 5.792,1.854 6.135,2.104 0.344,0.25 2.01,1.948 2.323,1.698 false 4.823,2.24 5.104,2.042 false 2.385,1.698 2.646,1.99 false 5.208,2.031 5.615,2.292 false 0.115,0.115 0.542,0.385 0.427,0.271 10 false *a 3.823,0.156 4.25,0.427 0.427,0.271 10 false *b 3.021,1.719 3.448,1.99 0.427,0.271 10 false L5 5.885,1.896 6.313,2.167 0.427,0.271 10 false c6 1.563,1.896 2.052,2.167 0.49,0.271 10 false SMRB 4.521,2.24 5.01,2.51 0.49,0.271 10 false SMRB 2.646,2.01 3.135,2.281 0.49,0.271 10 false SMRP 5.688,2.25 6.177,2.521 0.49,0.271 10 false SMRP

Standard Resistance:
Tester Connection Condition Specified Condition
L5-4 (SMRB) - c6-4 (SMRB) Power switch off Below 1 Ω
L5-3 (SMRP) - c6-3 (SMRP) Power switch off Below 1 Ω


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)
*b Rear view of wire harness connector
(to Hybrid Battery Junction Block Assembly)


f.

Reconnect the c6 hybrid battery junction block assembly connector.


g.

Install the No. 2 hybrid battery shield sub-assembly.


h.

Reconnect the L5 power management control ECU connector.



OK

11.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

11.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the hybrid battery junction block assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>COMPONENTS).


c.
U190682E02
0.092,0.085 0.317,0.283 0.225,0.198 10 *a 2.099,2.997 2.437,3.140 0.338,0.143 10 GND 1.322,2.997 1.766,3.140 0.444,0.143 10 SMRB 2.119,2.726 2.242,2.978 false 1.673,2.726 1.575,2.979 false 0.933,2.39 1.159,2.588 0.225,0.198 10 c6 0.572,1.875 0.798,2.072 0.225,0.198 10 T6 0.367,1.343 0.615,1.836 false 1.704,1.875 1.929,2.072 0.225,0.198 10 k3 2.05,1.338 1.828,1.836 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
k3-1 (+) - T6-1 (CBI) Auxiliary battery voltage is applied between terminals c6-4 (SMRB) and c6-2 (GND) Below 1 Ω


Text in Illustration
*a Component without harness connected
(Hybrid Battery Junction Block Assembly)


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
c6-4 (SMRB) - c6-2 (GND) -40 to 80 °C (-40 to 176°F) 19.0 to 35.5 Ω



e.

Install the hybrid battery junction block assembly.



OK

12.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)

NG

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

12.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the hybrid battery junction block assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>COMPONENTS).


c.
U190683E02
0.092,0.085 0.317,0.283 0.225,0.198 10 *a 2.099,2.997 2.437,3.140 0.338,0.143 10 GND 1.494,2.997 1.938,3.140 0.444,0.143 10 SMRP 2.119,2.726 2.242,2.978 false 1.845,2.726 1.747,2.979 false 0.933,2.39 1.159,2.588 0.225,0.198 10 c6 0.572,1.875 0.798,2.072 0.225,0.198 10 T5 0.374,0.924 0.615,1.836 false 3.028,0.614 3.254,0.811 0.225,0.198 10 h3 2.942,0.765 2.667,0.94 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
h3-1 (-) - T5-1 (CEI) Auxiliary battery voltage is applied between terminals c6-3 (SMRP) and c6-2 (GND) 28.5 to 31.5 Ω


Text in Illustration
*a Component without harness connected
(Hybrid Battery Junction Block Assembly)


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
c6-3 (SMRP) - c6-2 (GND) -40 to 80 °C (-40 to 176°F) 112 to 274 Ω



e.

Install the hybrid battery junction block assembly.



OK

13.CHECK FOR INTERMITTENT PROBLEMS

NG

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

13.CHECK FOR INTERMITTENT PROBLEMS

Result:
Result Proceed to
Problem symptom does not recur. A
Problem symptom recur. B


HINT:
·

Since 2 trip detection logic is used, the DTC detection condition must be met twice.

·

If DTC P3004-131 is output again after performing the inspection, replace the hybrid vehicle converter. If DTC P3004-131 is not output again, replace the hybrid battery junction block assembly.




A

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

B