Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › 2012.03–2014.11
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301574 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P31AB-123  Hybrid Battery Cell Low Voltage  


DESCRIPTION

The power management control ECU alerts the driver and performs fail-safe control based on error signals sent from the battery smart unit.

DTC No. INF Code DTC Detection Condition Trouble Area
P31AB 123 When battery cells are over discharged
(1 trip detection)
·

HV battery

·

Battery smart unit

·

Frame wire

·

Wire harness or connector

·

Hybrid battery junction block assembly

·

Inverter with converter assembly




WIRING DIAGRAM

Refer to the wiring diagram for DTC P301A-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P301A-123).

CAUTION / NOTICE / HINT

CAUTION:
·

This DTC may be stored even when the SOC is high.

·

Do not perform "HV Batt Cell Low Volt READY ON Prevention Cancel" unless specifically directed by the troubleshooting procedure. Doing so may cause a serious malfunction.

·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of HV battery, make sure to return them through an authorized collection agent who is capable of handling them safely. If they are returned via the manufacturer specified route, they will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.READ VALUE USING GTS (PM ECU - Batt Line 1 Volt and Batt Line 2 Volt)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Data List / PM ECU - Batt Line 1 Volt and Batt Line 2 Volt.

Result:
Tester Display Result Proceed to
PM ECU - Batt Line 1 Volt and Batt Line 2 Volt Hi A
PM ECU - Batt Line 1 Volt and Batt Line 2 Volt Lo B




A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

7.CHECK DTC OUTPUT (HYBRID CONTROL)
2.CHECK DTC OUTPUT (HYBRID CONTROL)

A

3.CHECK DTC OUTPUT (HYBRID CONTROL)

B

3.CHECK DTC OUTPUT (HYBRID CONTROL)

A

4.CHECK CONNECTOR CONNECTION CONDITION (BATTERY SMART UNIT CONNECTOR)

B

4.CHECK CONNECTOR CONNECTION CONDITION (BATTERY SMART UNIT CONNECTOR)

OK

5.CHECK HV BATTERY (BATTERY CELL VOLTAGE)

NG

CONNECT SECURELY

5.CHECK HV BATTERY (BATTERY CELL VOLTAGE)
CAUTION:

Be sure to wear insulated gloves.


a.

2012/05 - 2013/12:

i.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



ii.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


iii.

Disconnect the z26 battery smart unit connector.


iv.
U190740E02
2.74,3.146 2.365,3.542 false 2.74,3.01 2.969,3.156 false 2.74,2.948 2.99,2.875 false 2.656,3.146 2.094,3.396 false 2.646,3 2.042,2.854 false 2.646,2.938 2.25,2.594 false 2.646,3.073 2.073,3.135 false 2.74,3.073 2.958,3.375 false 2.531,2.156 2.948,2.344 0.417,0.188 10 false z26 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 3.021,2.781 3.385,2.948 0.365,0.167 10 false VA3 2.99,3.115 3.354,3.281 0.365,0.167 10 false VA2 1.729,2.76 2.042,2.927 0.313,0.167 10 false VA6 1.75,3.052 2.042,3.219 0.292,0.167 10 false VA5 1.781,3.354 2.094,3.521 0.313,0.167 10 false VA4 2.208,3.563 2.573,3.729 0.365,0.167 10 false GA0 1.906,2.49 2.208,2.688 0.302,0.198 10 false VA7 2.938,3.396 3.302,3.563 0.365,0.167 10 false VA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 0):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z26-13 (GA0) - z26-9 (VA1) 1 Power switch off 3.0 V or more
z26-9 (VA1) - z26-5 (VA2) 2 Power switch off 3.0 V or more
z26-5 (VA2) - z26-1 (VA3) 3 Power switch off 3.0 V or more
z26-1 (VA3) - z26-14 (VA4) 4 Power switch off 3.0 V or more
z26-14 (VA4) - z26-10 (VA5) 5 Power switch off 3.0 V or more
z26-10 (VA5) - z26-6 (VA6) 6 Power switch off 3.0 V or more
z26-6 (VA6) - z26-2 (VA7) 7 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



v.
U190741E02
2.521,3.146 2.24,3.542 false 2.594,3.063 2.927,3.271 false 2.51,3.073 2.063,3.344 false 2.688,2.938 3,2.771 false 2.594,3.146 2.865,3.521 false 2.51,2.938 2.021,2.875 false 2.51,3.01 1.938,3.135 false 2.594,3.01 2.927,3.031 false 2.552,2.156 2.938,2.344 0.385,0.188 10 false z26 0.188,0.146 0.354,0.313 0.167,0.167 10 false *a 2.958,3.25 3.323,3.417 0.365,0.167 10 false VA9 1.542,3.052 1.938,3.219 0.396,0.167 10 false VA13 1.646,3.292 2.021,3.458 0.375,0.167 10 false VA12 2.792,3.563 3.104,3.729 0.313,0.167 10 false VA8 2.021,3.552 2.385,3.719 0.365,0.167 10 false VA11 3.021,2.667 3.323,2.865 0.302,0.198 10 false VA7 1.625,2.771 2.021,2.938 0.396,0.167 10 false VA14 2.969,2.969 3.344,3.135 0.375,0.167 10 false VA10

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 1):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z26-2 (VA7) - z26-15 (VA8) 8 Power switch off 3.0 V or more
z26-15 (VA8) - z26-11 (VA9) 9 Power switch off 3.0 V or more
z26-11 (VA9) - z26-7 (VA10) 10 Power switch off 3.0 V or more
z26-7 (VA10) - z26-16 (VA11) 11 Power switch off 3.0 V or more
z26-16 (VA11) - z26-12 (VA12) 12 Power switch off 3.0 V or more
z26-12 (VA12) - z26-8 (VA13) 13 Power switch off 3.0 V or more
z26-8 (VA13) - z26-4 (VA14) 14 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



vi.

Reconnect the z26 battery smart unit connector.


vii.

Disconnect the z27 battery smart unit connector.


viii.
U190736E02
2.146,2.854 2.146,2.333 false 2.24,2.854 2.688,2.333 false 2.24,2.906 2.688,2.906 false 2.073,2.917 1.396,2.583 false 2.083,2.979 1.406,3.313 false 2.156,2.917 2.375,3.427 false 2.156,2.979 1.708,3.5 false 2.24,2.979 2.667,3.198 false 2,3.792 2.375,3.979 0.375,0.188 10 false z27 0.177,0.104 0.344,0.271 0.167,0.167 10 false *a 1.99,2.135 2.354,2.302 0.365,0.167 10 false VA19 2.615,2.156 2.979,2.323 0.365,0.167 10 false VA16 2.719,2.833 3.083,3 0.365,0.167 10 false VA15 0.99,2.469 1.354,2.635 0.365,0.167 10 false VA21 1.021,3.271 1.385,3.438 0.365,0.167 10 false VA20 2.281,3.469 2.646,3.635 0.365,0.167 10 false VA18 1.438,3.51 1.802,3.677 0.365,0.167 10 false VA17 2.688,3.135 3.052,3.302 0.365,0.167 10 false GA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 2):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z27-11 (GA1) - z27-6 (VA15) 15 Power switch off 3.0 V or more
z27-6 (VA15) - z27-1 (VA16) 16 Power switch off 3.0 V or more
z27-1 (VA16) - z27-12 (VA17) 17 Power switch off 3.0 V or more
z27-12 (VA17) - z27-7 (VA18) 18 Power switch off 3.0 V or more
z27-7 (VA18) - z27-2 (VA19) 19 Power switch off 3.0 V or more
z27-2 (VA19) - z27-13 (VA20) 20 Power switch off 3.0 V or more
z27-13 (VA20) - z27-8 (VA21) 21 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



ix.
U190737E02
2,2.844 2,2.323 false 2.083,2.833 2.531,2.313 false 2,2.917 2.583,3.26 false 1.917,2.844 1.469,2.323 false 1.917,2.917 1.24,2.583 false 1.927,2.979 1.25,3.313 false 2.083,2.917 2.729,2.698 false 2,2.979 1.552,3.5 false 2.01,3.792 2.479,3.979 0.469,0.188 10 false z27 0.198,0.135 0.365,0.302 0.167,0.167 10 false *a 1.854,2.135 2.219,2.302 0.365,0.167 10 false VA25 2.458,2.135 2.823,2.302 0.365,0.167 10 false VA22 2.625,3.219 2.99,3.385 0.365,0.167 10 false VA24 1.167,2.156 1.531,2.323 0.365,0.167 10 false VA28 0.844,2.458 1.208,2.625 0.365,0.167 10 false VA27 0.844,3.26 1.208,3.427 0.365,0.167 10 false VA26 2.76,2.573 3.198,2.792 0.438,0.219 10 false VA21 1.281,3.521 1.646,3.688 0.365,0.167 10 false VA23

Measure the voltage according to the value(s) in the table below .

Standard Voltage (Battery Block 3):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z27-8 (VA21) - z27-3 (VA22) 22 Power switch off 3.0 V or more
z27-3 (VA22) - z27-14 (VA23) 23 Power switch off 3.0 V or more
z27-14 (VA23) - z27-9 (VA24) 24 Power switch off 3.0 V or more
z27-9 (VA24) - z27-4 (VA25) 25 Power switch off 3.0 V or more
z27-4 (VA25) - z27-15 (VA26) 26 Power switch off 3.0 V or more
z27-15 (VA26) - z27-10 (VA27) 27 Power switch off 3.0 V or more
z27-10 (VA27) - z27-5 (VA28) 28 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



x.

Reconnect the z27 battery smart unit connector.


xi.

Disconnect the z22 battery smart unit connector.


xii.
U190732E02
1.698,2.844 1.958,2.542 false 1.542,2.906 0.865,2.781 false 1.542,2.979 0.865,3.25 false 1.625,2.906 2.104,2.813 false 1.615,2.979 1.167,3.5 false 1.698,2.917 2.115,3.188 false 1.604,2.844 1.167,2.469 false 1.698,2.969 1.865,3.448 false 1.448,2.094 1.75,2.281 0.302,0.188 10 false z22 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 0.792,2.354 1.156,2.521 0.365,0.167 10 false VA33 1.979,2.396 2.344,2.563 0.365,0.167 10 false VA30 2.135,3.135 2.5,3.302 0.365,0.167 10 false VA29 0.479,2.688 0.844,2.854 0.365,0.167 10 false VA35 0.469,3.188 0.833,3.354 0.365,0.167 10 false VA34 2.125,2.698 2.49,2.865 0.365,0.167 10 false VA32 0.875,3.51 1.24,3.677 0.365,0.167 10 false VA31 1.792,3.469 2.156,3.635 0.365,0.167 10 false GA2

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 4):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z22-11 (GA2) - z22-6 (VA29) 29 Power switch off 3.0 V or more
z22-6 (VA29) - z22-1 (VA30) 30 Power switch off 3.0 V or more
z22-1 (VA30) - z22-12 (VA31) 31 Power switch off 3.0 V or more
z22-12 (VA31) - z22-7 (VA32) 32 Power switch off 3.0 V or more
z22-7 (VA32) - z22-2 (VA33) 33 Power switch off 3.0 V or more
z22-2 (VA33) - z22-13 (VA34) 34 Power switch off 3.0 V or more
z22-13 (VA34) - z22-8 (VA35) 35 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xiii.
U190733E02
1.385,2.906 0.813,2.792 false 1.458,2.917 1.26,3.292 false 1.469,2.979 1.906,3.365 false 1.542,2.917 2.01,3.104 false 1.542,2.844 2.146,2.677 false 1.385,2.979 0.885,3.094 false 1.385,2.844 1.01,2.552 false 1.469,2.844 1.958,2.458 false 1.448,2.094 1.792,2.281 0.344,0.188 10 false z22 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 2.208,2.594 2.573,2.76 0.365,0.167 10 false VA36 2.052,3.052 2.479,3.24 0.427,0.188 10 false VA35 0.615,2.427 0.979,2.594 0.365,0.167 10 false VA42 0.406,2.719 0.771,2.885 0.365,0.167 10 false VA41 0.479,3.031 0.844,3.198 0.365,0.167 10 false VA40 1.042,3.313 1.406,3.479 0.365,0.167 10 false VA38 1.938,3.333 2.302,3.5 0.365,0.167 10 false VA37 1.99,2.365 2.354,2.563 0.365,0.198 10 false VA39

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 5):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z22-8 (VA35) - z22-3 (VA36) 36 Power switch off 3.0 V or more
z22-3 (VA36) - z22-14 (VA37) 37 Power switch off 3.0 V or more
z22-14 (VA37) - z22-9 (VA38) 38 Power switch off 3.0 V or more
z22-9 (VA38) - z22-4 (VA39) 39 Power switch off 3.0 V or more
z22-4 (VA39) - z22-15 (VA40) 40 Power switch off 3.0 V or more
z22-15 (VA40) - z22-10 (VA41) 41 Power switch off 3.0 V or more
z22-10 (VA41) - z22-5 (VA42) 42 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xiv.

Reconnect the z22 battery smart unit connector.


xv.

Disconnect the z23 battery smart unit connector.


xvi.
U190728E02
1.042,3.146 0.698,3.521 false 1.042,3.073 0.5,3.313 false 1.125,3 1.563,3.135 false 1.135,2.938 1.656,2.823 false 1.042,3.01 0.583,3.01 false 1.031,2.948 0.604,2.729 false 1.135,3.083 1.552,3.406 false 1.115,3.135 1.25,3.563 false 0.896,2.198 1.24,2.385 0.344,0.188 10 false z23 0.167,0.188 0.333,0.354 0.167,0.167 10 false *a 1.677,2.74 2.042,2.906 0.365,0.167 10 false VA45 1.625,3.083 1.99,3.25 0.365,0.167 10 false VA44 0.188,2.927 0.552,3.094 0.365,0.167 10 false VA48 1.583,3.375 1.948,3.542 0.365,0.167 10 false VA43 0.5,3.542 0.865,3.708 0.365,0.167 10 false VA46 0.115,3.24 0.479,3.406 0.365,0.167 10 false VA47 0.219,2.604 0.583,2.802 0.365,0.198 10 false VA49 1.156,3.573 1.521,3.74 0.365,0.167 10 false GA3

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 6):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z23-13 (GA3) - z23-9 (VA43) 43 Power switch off 3.0 V or more
z23-9 (VA43) - z23-5 (VA44) 44 Power switch off 3.0 V or more
z23-5 (VA44) - z23-1 (VA45) 45 Power switch off 3.0 V or more
z23-1 (VA45) - z23-14 (VA46) 46 Power switch off 3.0 V or more
z23-14 (VA46) - z23-10 (VA47) 47 Power switch off 3.0 V or more
z23-10 (VA47) - z23-6 (VA48) 48 Power switch off 3.0 V or more
z23-6 (VA48) - z23-2 (VA49) 49 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xvii.
U190729E02
0.875,3 0.615,2.854 false 0.885,3.146 0.625,3.375 false 0.969,3.135 0.854,3.656 false 0.969,3.083 1.406,3.396 false 0.885,3.073 0.573,3.135 false 0.896,2.948 1.438,2.604 false 0.969,3.01 1.521,3.104 false 1.052,2.938 1.458,2.865 false 0.917,2.188 1.24,2.375 0.323,0.188 10 false z23 0.177,0.177 0.344,0.344 0.167,0.167 10 false *a 1.438,3.396 1.802,3.573 0.365,0.177 10 false VA51 1.479,2.479 1.844,2.646 0.365,0.167 10 false VA56 0.229,2.75 0.594,2.917 0.365,0.167 10 false VA55 0.177,3.073 0.542,3.24 0.365,0.167 10 false VA54 0.271,3.323 0.635,3.49 0.365,0.167 10 false VA53 0.677,3.667 1.042,3.833 0.365,0.167 10 false VA50 1.573,3.042 1.938,3.24 0.365,0.198 10 false VA52 1.5,2.771 1.865,2.938 0.365,0.167 10 false VA49

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 7):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z23-2 (VA49) - z23-15 (VA50) 50 Power switch off 3.0 V or more
z23-15 (VA50) - z23-11 (VA51) 51 Power switch off 3.0 V or more
z23-11 (VA51) - z23-7 (VA52) 52 Power switch off 3.0 V or more
z23-7 (VA52) - z23-16 (VA53) 53 Power switch off 3.0 V or more
z23-16 (VA53) - z23-12 (VA54) 54 Power switch off 3.0 V or more
z23-12 (VA54) - z23-8 (VA55) 55 Power switch off 3.0 V or more
z23-8 (VA55) - z23-4 (VA56) 56 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.


Result:
Result Proceed to
The difference between the highest and lowest value is less than 0.3 V and every measured value is 3.0 V or more. A
Other than above. B



xviii.

Reconnect the z23 battery smart unit connector.


xix.

Install the No. 1 hybrid battery shield sub-assembly.



b.

2013/12 -:

i.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



ii.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


iii.

Disconnect the z32 battery smart unit connector.


iv.
U190742E02
2.729,3.135 2.354,3.531 true 2.74,3 2.969,3.146 true 2.74,2.938 2.99,2.865 true 2.656,3.135 2.094,3.385 true 2.646,3 2.042,2.854 true 2.646,2.938 2.25,2.594 true 2.656,3.063 2.083,3.125 true 2.75,3.073 2.969,3.375 true 2.531,2.167 2.948,2.354 0.417,0.188 10 false z32 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 3.021,2.771 3.385,2.938 0.365,0.167 10 false VA3 2.99,3.063 3.354,3.229 0.365,0.167 10 false VA2 1.74,2.75 2.052,2.917 0.313,0.167 10 false VA6 1.771,3.052 2.063,3.219 0.292,0.167 10 false VA5 1.781,3.333 2.094,3.5 0.313,0.167 10 false VA4 2.198,3.542 2.563,3.708 0.365,0.167 10 false GA0 1.927,2.469 2.229,2.667 0.302,0.198 10 false VA7 2.938,3.375 3.302,3.542 0.365,0.167 10 false VA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 0):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z32-13 (GA0) - z32-9 (VA1) 1 Power switch off 3.0 V or more
z32-9 (VA1) -z32-5 (VA2) 2 Power switch off 3.0 V or more
z32-5 (VA2) - z32-1 (VA3) 3 Power switch off 3.0 V or more
z32-1 (VA3) - z32-14 (VA4) 4 Power switch off 3.0 V or more
z32-14 (VA4) - z32-10 (VA5) 5 Power switch off 3.0 V or more
z32-10 (VA5) - z32-6 (VA6) 6 Power switch off 3.0 V or more
z32-6 (VA6) - z32-2 (VA7) 7 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



v.
U190743E02
2.51,3.135 2.229,3.531 true 2.604,3.073 2.938,3.281 true 2.5,3.063 2.052,3.333 true 2.667,2.938 2.979,2.771 true 2.594,3.135 2.865,3.51 true 2.51,2.938 2.021,2.875 true 2.51,3 1.938,3.125 true 2.594,3 2.927,3.021 true 2.542,2.167 2.927,2.354 0.385,0.188 10 false z32 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 2.958,3.229 3.323,3.396 0.365,0.167 10 false VA9 1.542,3.042 1.938,3.208 0.396,0.167 10 false VA13 1.646,3.292 2.021,3.458 0.375,0.167 10 false VA12 2.781,3.542 3.094,3.708 0.313,0.167 10 false VA8 2.021,3.542 2.385,3.708 0.365,0.167 10 false VA11 3.01,2.677 3.313,2.875 0.302,0.198 10 false VA7 1.635,2.781 2.031,2.948 0.396,0.167 10 false VA14 2.969,2.948 3.344,3.115 0.375,0.167 10 false VA10

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 1):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z32-2 (VA7) - z32-15 (VA8) 8 Power switch off 3.0 V or more
z32-15 (VA8) - z32-11 (VA9) 9 Power switch off 3.0 V or more
z32-11 (VA9) - z32-7 (VA10) 10 Power switch off 3.0 V or more
z32-7 (VA10) - z32-16 (VA11) 11 Power switch off 3.0 V or more
z32-16 (VA11) - z32-12 (VA12) 12 Power switch off 3.0 V or more
z32-12 (VA12) - z32-8 (VA13) 13 Power switch off 3.0 V or more
z32-8 (VA13) - z32-4 (VA14) 14 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



vi.

Reconnect the z32 battery smart unit connector.


vii.

Disconnect the z33 battery smart unit connector.


viii.
U190738E02
2.156,2.833 2.156,2.313 true 2.24,2.844 2.688,2.323 true 2.24,2.906 2.688,2.906 true 2.083,2.844 1.406,2.51 false 2.073,2.844 1.396,2.51 true 2.083,2.906 1.406,3.24 false 2.083,2.906 1.406,3.24 true 2.156,2.906 2.375,3.417 true 2.146,2.979 1.698,3.5 true 2.24,2.969 2.667,3.188 true 2,3.802 2.375,3.99 0.375,0.188 10 false z33 0.177,0.104 0.344,0.271 0.167,0.167 10 false *a 2,2.125 2.365,2.292 0.365,0.167 10 false VA19 2.615,2.146 2.979,2.313 0.365,0.167 10 false VA16 2.719,2.844 3.083,3.01 0.365,0.167 10 false VA15 1.01,2.417 1.375,2.583 0.365,0.167 10 false VA21 1.031,3.177 1.396,3.344 0.365,0.167 10 false VA20 2.26,3.438 2.625,3.604 0.365,0.167 10 false VA18 1.448,3.531 1.813,3.698 0.365,0.167 10 false VA17 2.708,3.135 3.073,3.302 0.365,0.167 10 false GA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 2):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z33-11 (GA1) - z33-6 (VA15) 15 Power switch off 3.0 V or more
z33-6 (VA15) - z33-1 (VA16) 16 Power switch off 3.0 V or more
z33-1 (VA16) - z33-12 (VA17) 17 Power switch off 3.0 V or more
z33-12 (VA17) - z33-7 (VA18) 18 Power switch off 3.0 V or more
z33-7 (VA18) - z33-2 (VA19) 19 Power switch off 3.0 V or more
z33-2 (VA19) - z33-13 (VA20) 20 Power switch off 3.0 V or more
z33-13 (VA20) - z33-8 (VA21) 21 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



ix.
U190739E02
2,2.833 2,2.313 true 2.094,2.844 2.542,2.323 true 2,2.927 2.583,3.271 true 1.917,2.844 1.469,2.323 true 1.927,2.906 1.25,2.573 true 1.917,2.969 1.24,3.302 true 2.083,2.906 2.729,2.688 true 2,2.969 1.552,3.49 true 2.01,3.802 2.479,3.99 0.469,0.188 10 false z33 0.177,0.104 0.344,0.271 0.167,0.167 10 false *a 1.833,2.094 2.198,2.26 0.365,0.167 10 false VA25 2.458,2.125 2.823,2.292 0.365,0.167 10 false VA22 2.625,3.198 2.99,3.365 0.365,0.167 10 false VA24 1.188,2.125 1.552,2.292 0.365,0.167 10 false VA28 0.875,2.458 1.24,2.625 0.365,0.167 10 false VA27 0.875,3.281 1.24,3.448 0.365,0.167 10 false VA26 2.76,2.552 3.198,2.771 0.438,0.219 10 false VA21 1.271,3.51 1.635,3.677 0.365,0.167 10 false VA23

Measure the voltage according to the value(s) in the table below .

Standard Voltage (Battery Block 3):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z33-8 (VA21) - z33-3 (VA22) 22 Power switch off 3.0 V or more
z33-3 (VA22) - z33-14 (VA23) 23 Power switch off 3.0 V or more
z33-14 (VA23) - z33-9 (VA24) 24 Power switch off 3.0 V or more
z33-9 (VA24) - z33-4 (VA25) 25 Power switch off 3.0 V or more
z33-4 (VA25) - z33-15 (VA26) 26 Power switch off 3.0 V or more
z33-15 (VA26) - z33-10 (VA27) 27 Power switch off 3.0 V or more
z33-10 (VA27) - z33-5 (VA28) 28 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



x.

Reconnect the z33 battery smart unit connector.


xi.

Disconnect the z30 battery smart unit connector.


xii.
U190734E02
1.698,2.844 1.958,2.542 true 1.542,2.906 0.865,2.781 true 1.531,2.969 0.854,3.24 true 1.615,2.896 2.094,2.802 true 1.615,2.979 1.167,3.5 true 1.698,2.906 2.115,3.177 true 1.625,2.833 1.188,2.458 true 1.698,2.979 1.865,3.458 true 1.458,2.115 1.76,2.302 0.302,0.188 10 false z30 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 0.833,2.344 1.198,2.51 0.365,0.167 10 false VA33 1.979,2.406 2.344,2.573 0.365,0.167 10 false VA30 2.135,3.135 2.5,3.302 0.365,0.167 10 false VA29 0.479,2.656 0.844,2.823 0.365,0.167 10 false VA35 0.49,3.167 0.854,3.333 0.365,0.167 10 false VA34 2.125,2.698 2.49,2.865 0.365,0.167 10 false VA32 0.906,3.5 1.271,3.667 0.365,0.167 10 false VA31 1.792,3.479 2.156,3.646 0.365,0.167 10 false GA2

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 4):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z30-11 (GA2) - z30-6 (VA29) 29 Power switch off 3.0 V or more
z30-6 (VA29) - z30-1 (VA30) 30 Power switch off 3.0 V or more
z30-1 (VA30) - z30-12 (VA31) 31 Power switch off 3.0 V or more
z30-12 (VA31) - z30-7 (VA32) 32 Power switch off 3.0 V or more
z30-7 (VA32) - z30-2 (VA33) 33 Power switch off 3.0 V or more
z30-2 (VA33) - z30-13 (VA34) 34 Power switch off 3.0 V or more
z30-13 (VA34) - z30-8 (VA35) 35 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xiii.
U190735E02
1.375,2.896 0.802,2.781 true 1.469,2.906 1.271,3.281 true 1.469,2.979 1.906,3.365 true 1.552,2.906 2.021,3.094 true 1.552,2.844 2.156,2.677 true 1.375,2.969 0.875,3.083 true 1.375,2.833 1,2.542 true 1.469,2.844 1.958,2.458 true 1.458,2.104 1.802,2.292 0.344,0.188 10 false z30 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 2.208,2.583 2.573,2.75 0.365,0.167 10 false VA36 2.073,3.021 2.5,3.208 0.427,0.188 10 false VA35 0.615,2.417 0.979,2.583 0.365,0.167 10 false VA42 0.417,2.688 0.781,2.854 0.365,0.167 10 false VA41 0.5,3.01 0.865,3.177 0.365,0.167 10 false VA40 1.052,3.292 1.417,3.458 0.365,0.167 10 false VA38 1.948,3.323 2.313,3.49 0.365,0.167 10 false VA37 2,2.354 2.365,2.552 0.365,0.198 10 false VA39

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 5):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z30-8 (VA35) - z30-3 (VA36) 36 Power switch off 3.0 V or more
z30-3 (VA36) - z30-14 (VA37) 37 Power switch off 3.0 V or more
z30-14 (VA37) - z30-9 (VA38) 38 Power switch off 3.0 V or more
z30-9 (VA38) - z30-4 (VA39) 39 Power switch off 3.0 V or more
z30-4 (VA39) - z30-15 (VA40) 40 Power switch off 3.0 V or more
z30-15 (VA40) - z30-10 (VA41) 41 Power switch off 3.0 V or more
z30-10 (VA41) - z30-5 (VA42) 42 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xiv.

Reconnect the z30 battery smart unit connector.


xv.

Disconnect the z31 battery smart unit connector.


xvi.
U190730E02
1.031,3.135 0.688,3.51 true 1.031,3.063 0.49,3.302 true 1.135,3.01 1.573,3.146 true 1.125,2.938 1.646,2.823 true 1.042,3.01 0.583,3.01 true 1.031,2.938 0.604,2.719 true 1.125,3.073 1.542,3.396 true 1.125,3.135 1.26,3.563 true 0.906,2.208 1.25,2.396 0.344,0.188 10 false z31 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 1.688,2.719 2.052,2.885 0.365,0.167 10 false VA45 1.635,3.073 2,3.24 0.365,0.167 10 false VA44 0.208,2.927 0.573,3.094 0.365,0.167 10 false VA48 1.583,3.344 1.948,3.51 0.365,0.167 10 false VA43 0.479,3.531 0.844,3.698 0.365,0.167 10 false VA46 0.125,3.24 0.49,3.406 0.365,0.167 10 false VA47 0.24,2.615 0.604,2.813 0.365,0.198 10 false VA49 1.135,3.573 1.5,3.74 0.365,0.167 10 false GA3

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 6):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z31-13 (GA3) - z31-9 (VA43) 43 Power switch off 3.0 V or more
z31-9 (VA43) - z31-5 (VA44) 44 Power switch off 3.0 V or more
z31-5 (VA44) - z31-1 (VA45) 45 Power switch off 3.0 V or more
z31-1 (VA45) - z31-14 (VA46) 46 Power switch off 3.0 V or more
z31-14 (VA46) - z31-10 (VA47) 47 Power switch off 3.0 V or more
z31-10 (VA47) - z31-6 (VA48) 48 Power switch off 3.0 V or more
z31-6 (VA48) - z31-2 (VA49) 49 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xvii.
U190731E02
0.885,3 0.625,2.854 true 0.885,3.135 0.625,3.365 true 0.969,3.135 0.854,3.656 true 0.979,3.073 1.417,3.385 true 0.875,3.073 0.563,3.135 true 0.896,2.938 1.438,2.594 true 0.969,3.01 1.521,3.104 true 1.052,2.948 1.458,2.875 true 0.917,2.198 1.24,2.385 0.323,0.188 10 false z31 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 1.406,3.406 1.771,3.583 0.365,0.177 10 false VA51 1.469,2.49 1.833,2.656 0.365,0.167 10 false VA56 0.25,2.771 0.615,2.938 0.365,0.167 10 false VA55 0.188,3.063 0.552,3.229 0.365,0.167 10 false VA54 0.271,3.354 0.635,3.521 0.365,0.167 10 false VA53 0.667,3.667 1.031,3.833 0.365,0.167 10 false VA50 1.552,3.042 1.917,3.24 0.365,0.198 10 false VA52 1.49,2.771 1.854,2.938 0.365,0.167 10 false VA49

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 7):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z31-2 (VA49) - z31-15 (VA50) 50 Power switch off 3.0 V or more
z31-15 (VA50) - z31-11 (VA51) 51 Power switch off 3.0 V or more
z31-11 (VA51) - z31-7 (VA52) 52 Power switch off 3.0 V or more
z31-7 (VA52) - z31-16 (VA53) 53 Power switch off 3.0 V or more
z31-16 (VA53) - z31-12 (VA54) 54 Power switch off 3.0 V or more
z31-12 (VA54) - z31-8 (VA55) 55 Power switch off 3.0 V or more
z31-8 (VA55) - z31-4 (VA56) 56 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.


Result:
Result Proceed to
The difference between the highest and lowest value is less than 0.3 V and every measured value is 3.0 V or more. A
Other than above. B



xviii.

Reconnect the z31 battery smart unit connector.


xix.

Install the No. 1 hybrid battery shield sub-assembly.




A

B

6.CHECK BATTERY SMART UNIT
6.CHECK BATTERY SMART UNIT
NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance.


a.

2012/05 - 2013/12:


ii.

Measure the resistance according to the value(s) in the table below.

HINT:
·

If the voltage of any cell of the HV battery was less than 3.0 V, measure the resistance of the battery smart unit at the terminals which relate to that battery cell.

·

If the difference between the highest and lowest measured cell voltage of each battery block is 0.3 V or more, measure the resistance of the battery smart unit at the terminals which relate to the cell with the lowest measured voltage.



A417508C02
1.156,2.229 1.594,2.521 0.438,0.292 1.885,2.229 2.323,2.521 0.438,0.292 2.563,2.24 3,2.531 0.438,0.292 3.271,2.25 3.708,2.542 0.438,0.292 0.344,0.115 1,0.729 0.656,0.615 10 false *a 1.271,2.271 1.854,2.615 0.583,0.344 10 false z23 2.01,2.271 2.594,2.615 0.583,0.344 10 false z22 2.667,2.281 3.25,2.625 0.583,0.344 10 false z27 3.385,2.302 3.969,2.646 0.583,0.344 10 false z26
*a Component without harness connected
(Battery Smart Unit)
- -


Standard Resistance (Battery Block 0):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z26-13 (GA0) (-) - z26-9 (VA1) (+) 1 Always 50 kΩ or higher
z26-9 (VA1) (-) - z26-5 (VA2) (+) 2 Always 50 kΩ or higher
z26-5 (VA2) (-) - z26-1 (VA3) (+) 3 Always 50 kΩ or higher
z26-1 (VA3) (-) - z26-14 (VA4) (+) 4 Always 50 kΩ or higher
z26-14 (VA4) (-) - z26-10 (VA5) (+) 5 Always 50 kΩ or higher
z26-10 (VA5) (-) - z26-6 (VA6) (+) 6 Always 50 kΩ or higher
z26-6 (VA6) (-) - z26-2 (VA7) (+) 7 Always 50 kΩ or higher
z26-13 (GA0) (-) -z26-2 (VA7) (+)
·

1

·

2

·

3

·

4

·

5

·

6

·

7


Always 350 kΩ or higher


Standard Resistance (Battery Block 1):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z26-2 (VA7) (-) - z26-15 (VA8) (+) 8 Always 50 kΩ or higher
z26-15 (VA8) (-) - z26-11 (VA9) (+) 9 Always 50 kΩ or higher
z26-11 (VA9) (-) - z26-7 (VA10) (+) 10 Always 50 kΩ or higher
z26-7 (VA10) (-) - z26-16 (VA11) (+) 11 Always 50 kΩ or higher
z26-16 (VA11) (-) - z26-12 (VA12) (+) 12 Always 50 kΩ or higher
z26-12 (VA12) (-) - z26-8 (VA13) (+) 13 Always 50 kΩ or higher
z26-8 (VA13) (-) - z26-4 (VA14) (+) 14 Always 50 kΩ or higher
z26-2 (VA7) (-) - z26-4 (VA14) (+)
·

8

·

9

·

10

·

11

·

12

·

13

·

14


Always 350 kΩ or higher


Standard Resistance (Battery Block 2):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z27-11 (GA1) (-) - z27-6 (VA15) (+) 15 Always 50 kΩ or higher
z27-6 (VA15) (-) - z27-1 (VA16) (+) 16 Always 50 kΩ or higher
z27-1 (VA16) (-) - z27-12 (VA17) (+) 17 Always 50 kΩ or higher
z27-12 (VA17) (-) - z27-7 (VA18) (+) 18 Always 50 kΩ or higher
z27-7 (VA18) (-) - z27-2 (VA19) (+) 19 Always 50 kΩ or higher
z27-2 (VA19) (-) - z27-13 (VA20) (+) 20 Always 50 kΩ or higher
z27-13 (VA20) (-) - z27-8 (VA21) (+) 21 Always 50 kΩ or higher
z27-11 (GA1) (-) - z27-8 (VA21) (+)
·

15

·

16

·

17

·

18

·

19

·

20

·

21


Always 350 kΩ or higher


Standard Resistance (Battery Block 3):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z27-8 (VA21) (-) - z27-3 (VA22) (+) 22 Always 50 kΩ or higher
z27-3 (VA22) (-) - z27-14 (VA23) (+) 23 Always 50 kΩ or higher
z27-14 (VA23) (-) - z27-9 (VA24) (+) 24 Always 50 kΩ or higher
z27-9 (VA24) (-) - z27-4 (VA25) (+) 25 Always 50 kΩ or higher
z27-4 (VA25) (-) - z27-15 (VA26) (+) 26 Always 50 kΩ or higher
z27-15 (VA26) (-) - z27-10 (VA27) (+) 27 Always 50 kΩ or higher
z27-10 (VA27) (-) - z27-5 (VA28) (+) 28 Always 50 kΩ or higher
z27-8 (VA21) (-) - z27-5 (VA28) (+)
·

22

·

23

·

24

·

25

·

26

·

27

·

28


Always 350 kΩ or higher


Standard Resistance (Battery Block 4):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z22-11 (GA2) (-) - z22-6 (VA29) (+) 29 Always 50 kΩ or higher
z22-6 (VA29) (-) - z22-1 (VA30) (+) 30 Always 50 kΩ or higher
z22-1 (VA30) (-) - z22-12 (VA31) (+) 31 Always 50 kΩ or higher
z22-12 (VA31) (-) - z22-7 (VA32) (+) 32 Always 50 kΩ or higher
z22-7 (VA32) (-) - z22-2 (VA33) (+) 33 Always 50 kΩ or higher
z22-2 (VA33) (-) - z22-13 (VA34) (+) 34 Always 50 kΩ or higher
z22-13 (VA34) (-) - z22-8 (VA35) (+) 35 Always 50 kΩ or higher
z22-11 (GA2) (-) - z22-8 (VA35) (+)
·

29

·

30

·

31

·

32

·

33

·

34

·

35


Always 350 kΩ or higher


Standard Resistance (Battery Block 5):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z22-8 (VA35) (-) - z22-3 (VA36) (+) 36 Always 50 kΩ or higher
z22-3 (VA36) (-) - z22-14 (VA37) (+) 37 Always 50 kΩ or higher
z22-14 (VA37) (-) - z22-9 (VA38) (+) 38 Always 50 kΩ or higher
z22-9 (VA38) (-) - z22-4 (VA39) (+) 39 Always 50 kΩ or higher
z22-4 (VA39) (-) - z22-15 (VA40) (+) 40 Always 50 kΩ or higher
z22-15 (VA40) (-) - z22-10 (VA41) (+) 41 Always 50 kΩ or higher
z22-10 (VA41) (-) - z22-5 (VA42) (+) 42 Always 50 kΩ or higher
z22-8 (VA35) (-) - z22-5 (VA42) (+)
·

36

·

37

·

38

·

39

·

40

·

41

·

42


Always 350 kΩ or higher


Standard Resistance (Battery Block 6):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z23-13 (GA3) (-) - z23-9 (VA43) (+) 43 Always 50 kΩ or higher
z23-9 (VA43) (-) - z23-5 (VA44) (+) 44 Always 50 kΩ or higher
z23-5 (VA44) (-) - z23-1 (VA45) (+) 45 Always 50 kΩ or higher
z23-1 (VA45) (-) - z23-14 (VA46) (+) 46 Always 50 kΩ or higher
z23-14 (VA46) (-) - z23-10 (VA47) (+) 47 Always 50 kΩ or higher
z23-10 (VA47) (-) - z23-6 (VA48) (+) 48 Always 50 kΩ or higher
z23-6 (VA48) (-) - z23-2 (VA49) (+) 49 Always 50 kΩ or higher
z23-13 (GA3) (-) - z23-2 (VA49) (+)
·

43

·

44

·

45

·

46

·

47

·

48

·

49


Always 350 kΩ or higher


Standard Resistance (Battery Block 7):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z23-2 (VA49) (-) - z23-15 (VA50) (+) 50 Always 50 kΩ or higher
z23-15 (VA50) (-) - z23-11 (VA51) (+) 51 Always 50 kΩ or higher
z23-11 (VA51) (-) - z23-7 (VA52) (+) 52 Always 50 kΩ or higher
z23-7 (VA52) (-) - z23-16 (VA53) (+) 53 Always 50 kΩ or higher
z23-16 (VA53) (-) - z23-12 (VA54) (+) 54 Always 50 kΩ or higher
z23-12 (VA54) (-) - z23-8 (VA55) (+) 55 Always 50 kΩ or higher
z23-8 (VA55) (-) - z23-4 (VA56) (+) 56 Always 50 kΩ or higher
z23-2 (VA49) (-) - z23-4 (VA56) (+)
·

50

·

51

·

52

·

53

·

54

·

55

·

56


Always 350 kΩ or higher


NOTICE:
·

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.

·

Read the resistance after the value has stabilized.

·

In order to avoid damaging the terminals of the battery smart unit, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery smart unit.




iii.

Install the battery smart unit.

Result:
Result Proceed to
All measured values were within specified range. A
Other than above. B




b.

2013/12 -:


ii.

Measure the resistance according to the value(s) in the table below.

HINT:
·

If the voltage of any cell of the HV battery was less than 3.0 V, measure the resistance of the battery smart unit at the terminals which relate to that battery cell.

·

If the difference between the highest and lowest measured cell voltage of each battery block is 0.3 V or more, measure the resistance of the battery smart unit at the terminals which relate to the cell with the lowest measured voltage.



A417508C03
1.156,2.229 1.594,2.521 0.438,0.292 1.885,2.229 2.323,2.521 0.438,0.292 2.563,2.24 3,2.531 0.438,0.292 3.271,2.25 3.708,2.542 0.438,0.292 0.344,0.115 1,0.729 0.656,0.615 10 false *a 1.271,2.271 1.854,2.615 0.583,0.344 10 false z31 2.01,2.271 2.594,2.615 0.583,0.344 10 false z30 2.667,2.281 3.25,2.625 0.583,0.344 10 false z33 3.365,2.302 3.948,2.646 0.583,0.344 10 false z32
*a Component without harness connected
(Battery Smart Unit)
- -


Standard Resistance (Battery Block 0):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z32-13 (GA0) (-) - z32-9 (VA1) (+) 1 Always 50 kΩ or higher
z32-9 (VA1) (-) - z32-5 (VA2) (+) 2 Always 50 kΩ or higher
z32-5 (VA2) (-) - z32-1 (VA3) (+) 3 Always 50 kΩ or higher
z32-1 (VA3) (-) - z32-14 (VA4) (+) 4 Always 50 kΩ or higher
z32-14 (VA4) (-) - z32-10 (VA5) (+) 5 Always 50 kΩ or higher
z32-10 (VA5) (-) - z32-6 (VA6) (+) 6 Always 50 kΩ or higher
z32-6 (VA6) (-) - z32-2 (VA7) (+) 7 Always 50 kΩ or higher
z32-13 (GA0) (-) -z32-2 (VA7) (+)
·

1

·

2

·

3

·

4

·

5

·

6

·

7


Always 350 kΩ or higher


Standard Resistance (Battery Block 1):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z32-2 (VA7) (-) - z32-15 (VA8) (+) 8 Always 50 kΩ or higher
z32-15 (VA8) (-) - z32-11 (VA9) (+) 9 Always 50 kΩ or higher
z32-11 (VA9) (-) - z32-7 (VA10) (+) 10 Always 50 kΩ or higher
z32-7 (VA10) (-) - z32-16 (VA11) (+) 11 Always 50 kΩ or higher
z32-16 (VA11) (-) - z32-12 (VA12) (+) 12 Always 50 kΩ or higher
z32-12 (VA12) (-) - z32-8 (VA13) (+) 13 Always 50 kΩ or higher
z32-8 (VA13) (-) - z32-4 (VA14) (+) 14 Always 50 kΩ or higher
z32-2 (VA7) (-) - z32-4 (VA14) (+)
·

8

·

9

·

10

·

11

·

12

·

13

·

14


Always 350 kΩ or higher


Standard Resistance (Battery Block 2):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z33-11 (GA1) (-) - z33-6 (VA15) (+) 15 Always 50 kΩ or higher
z33-6 (VA15) (-) - z33-1 (VA16) (+) 16 Always 50 kΩ or higher
z33-1 (VA16) (-) - z33-12 (VA17) (+) 17 Always 50 kΩ or higher
z33-12 (VA17) (-) - z33-7 (VA18) (+) 18 Always 50 kΩ or higher
z33-7 (VA18) (-) - z33-2 (VA19) (+) 19 Always 50 kΩ or higher
z33-2 (VA19) (-) - z33-13 (VA20) (+) 20 Always 50 kΩ or higher
z33-13 (VA20) (-) - z33-8 (VA21) (+) 21 Always 50 kΩ or higher
z33-11 (GA1) (-) - z33-8 (VA21) (+)
·

15

·

16

·

17

·

18

·

19

·

20

·

21


Always 350 kΩ or higher


Standard Resistance (Battery Block 3):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z33-8 (VA21) (-) - z33-3 (VA22) (+) 22 Always 50 kΩ or higher
z33-3 (VA22) (-) - z33-14 (VA23) (+) 23 Always 50 kΩ or higher
z33-14 (VA23) (-) - z33-9 (VA24) (+) 24 Always 50 kΩ or higher
z33-9 (VA24) (-) - z33-4 (VA25) (+) 25 Always 50 kΩ or higher
z33-4 (VA25) (-) - z33-15 (VA26) (+) 26 Always 50 kΩ or higher
z33-15 (VA26) (-) - z33-10 (VA27) (+) 27 Always 50 kΩ or higher
z33-10 (VA27) (-) - z33-5 (VA28) (+) 28 Always 50 kΩ or higher
z33-8 (VA21) (-) - z33-5 (VA28) (+)
·

22

·

23

·

24

·

25

·

26

·

27

·

28


Always 350 kΩ or higher


Standard Resistance (Battery Block 4):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z30-11 (GA2) (-) - z30-6 (VA29) (+) 29 Always 50 kΩ or higher
z30-6 (VA29) (-) - z30-1 (VA30) (+) 30 Always 50 kΩ or higher
z30-1 (VA30) (-) - z30-12 (VA31) (+) 31 Always 50 kΩ or higher
z30-12 (VA31) (-) - z30-7 (VA32) (+) 32 Always 50 kΩ or higher
z30-7 (VA32) (-) - z30-2 (VA33) (+) 33 Always 50 kΩ or higher
z30-2 (VA33) (-) - z30-13 (VA34) (+) 34 Always 50 kΩ or higher
z30-13 (VA34) (-) - z30-8 (VA35) (+) 35 Always 50 kΩ or higher
z30-11 (GA2) (-) - z30-8 (VA35) (+)
·

29

·

30

·

31

·

32

·

33

·

34

·

35


Always 350 kΩ or higher


Standard Resistance (Battery Block 5):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z30-8 (VA35) (-) - z30-3 (VA36) (+) 36 Always 50 kΩ or higher
z30-3 (VA36) (-) - z30-14 (VA37) (+) 37 Always 50 kΩ or higher
z30-14 (VA37) (-) - z30-9 (VA38) (+) 38 Always 50 kΩ or higher
z30-9 (VA38) (-) - z30-4 (VA39) (+) 39 Always 50 kΩ or higher
z30-4 (VA39) (-) - z30-15 (VA40) (+) 40 Always 50 kΩ or higher
z30-15 (VA40) (-) - z30-10 (VA41) (+) 41 Always 50 kΩ or higher
z30-10 (VA41) (-) - z30-5 (VA42) (+) 42 Always 50 kΩ or higher
z30-8 (VA35) (-) - z30-5 (VA42) (+)
·

36

·

37

·

38

·

39

·

40

·

41

·

42


Always 350 kΩ or higher


Standard Resistance (Battery Block 6):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z31-13 (GA3) (-) - z31-9 (VA43) (+) 43 Always 50 kΩ or higher
z31-9 (VA43) (-) - z31-5 (VA44) (+) 44 Always 50 kΩ or higher
z31-5 (VA44) (-) - z31-1 (VA45) (+) 45 Always 50 kΩ or higher
z31-1 (VA45) (-) - z31-14 (VA46) (+) 46 Always 50 kΩ or higher
z31-14 (VA46) (-) - z31-10 (VA47) (+) 47 Always 50 kΩ or higher
z31-10 (VA47) (-) - z31-6 (VA48) (+) 48 Always 50 kΩ or higher
z31-6 (VA48) (-) - z31-2 (VA49) (+) 49 Always 50 kΩ or higher
z31-13 (GA3) (-) - z31-2 (VA49) (+)
·

43

·

44

·

45

·

46

·

47

·

48

·

49


Always 350 kΩ or higher


Standard Resistance (Battery Block 7):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z31-2 (VA49) (-) - z31-15 (VA50) (+) 50 Always 50 kΩ or higher
z31-15 (VA50) (-) - z31-11 (VA51) (+) 51 Always 50 kΩ or higher
z31-11 (VA51) (-) - z31-7 (VA52) (+) 52 Always 50 kΩ or higher
z31-7 (VA52) (-) - z31-16 (VA53) (+) 53 Always 50 kΩ or higher
z31-16 (VA53) (-) - z31-12 (VA54) (+) 54 Always 50 kΩ or higher
z31-12 (VA54) (-) - z31-8 (VA55) (+) 55 Always 50 kΩ or higher
z31-8 (VA55) (-) - z31-4 (VA56) (+) 56 Always 50 kΩ or higher
z31-2 (VA49) (-) - z31-4 (VA56) (+)
·

50

·

51

·

52

·

53

·

54

·

55

·

56


Always 350 kΩ or higher


NOTICE:
·

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.

·

Read the resistance after the value has stabilized.

·

In order to avoid damaging the terminals of the battery smart unit, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery smart unit.




iii.

Install the battery smart unit.

Result:
Result Proceed to
All measured values were within specified range. A
Other than above. B





A

B

30.REPLACE BATTERY SMART UNIT
7.CHECK DTC OUTPUT (HYBRID CONTROL)

A

8.SYSTEM CHECK (HYBRID CONTROL)

B

8.SYSTEM CHECK (HYBRID CONTROL)
CAUTION:

Before repairing or replacing the malfunctioning part, do not perform "HV Batt Cell Low Volt READY ON Prevention Cancel".


a.

While depressing the brake pedal, press the power switch and check that the hybrid system turns on (READY).

NOTICE:

Do not turn the power switch on (READY) repeatedly.

Doing so may cause a malfunction.



Result:
Result Proceed to
Hybrid system starts. A
Hybrid system does not start. B


b.

Turn the power switch off.



A

9.CHECK DTC OUTPUT (HYBRID CONTROL)

B

13.CHECK DTC OUTPUT (HYBRID CONTROL)
9.CHECK DTC OUTPUT (HYBRID CONTROL)

A

10.CHECK CONNECTOR CONNECTION CONDITION (BATTERY SMART UNIT CONNECTOR)

B

10.CHECK CONNECTOR CONNECTION CONDITION (BATTERY SMART UNIT CONNECTOR)

OK

11.CHECK HV BATTERY (BATTERY CELL VOLTAGE)

NG

CONNECT SECURELY

11.CHECK HV BATTERY (BATTERY CELL VOLTAGE)
CAUTION:

Be sure to wear insulated gloves.


a.

2012/05 - 2013/12:

i.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



ii.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


iii.

Disconnect the z26 battery smart unit connector.


iv.
U190740E02
2.74,3.146 2.365,3.542 false 2.74,3.01 2.969,3.156 false 2.74,2.948 2.99,2.875 false 2.656,3.146 2.094,3.396 false 2.646,3 2.042,2.854 false 2.646,2.938 2.25,2.594 false 2.646,3.073 2.073,3.135 false 2.74,3.073 2.958,3.375 false 2.531,2.156 2.948,2.344 0.417,0.188 10 false z26 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 3.021,2.781 3.385,2.948 0.365,0.167 10 false VA3 2.99,3.115 3.354,3.281 0.365,0.167 10 false VA2 1.729,2.76 2.042,2.927 0.313,0.167 10 false VA6 1.75,3.052 2.042,3.219 0.292,0.167 10 false VA5 1.781,3.354 2.094,3.521 0.313,0.167 10 false VA4 2.208,3.563 2.573,3.729 0.365,0.167 10 false GA0 1.906,2.49 2.208,2.688 0.302,0.198 10 false VA7 2.938,3.396 3.302,3.563 0.365,0.167 10 false VA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 0):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z26-13 (GA0) - z26-9 (VA1) 1 Power switch off 3.0 V or more
z26-9 (VA1) - z26-5 (VA2) 2 Power switch off 3.0 V or more
z26-5 (VA2) - z26-1 (VA3) 3 Power switch off 3.0 V or more
z26-1 (VA3) - z26-14 (VA4) 4 Power switch off 3.0 V or more
z26-14 (VA4) - z26-10 (VA5) 5 Power switch off 3.0 V or more
z26-10 (VA5) - z26-6 (VA6) 6 Power switch off 3.0 V or more
z26-6 (VA6) - z26-2 (VA7) 7 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



v.
U190741E02
2.521,3.146 2.24,3.542 false 2.594,3.063 2.927,3.271 false 2.51,3.073 2.063,3.344 false 2.688,2.938 3,2.771 false 2.594,3.146 2.865,3.521 false 2.51,2.938 2.021,2.875 false 2.51,3.01 1.938,3.135 false 2.594,3.01 2.927,3.031 false 2.552,2.156 2.938,2.344 0.385,0.188 10 false z26 0.188,0.146 0.354,0.313 0.167,0.167 10 false *a 2.958,3.25 3.323,3.417 0.365,0.167 10 false VA9 1.542,3.052 1.938,3.219 0.396,0.167 10 false VA13 1.646,3.292 2.021,3.458 0.375,0.167 10 false VA12 2.792,3.563 3.104,3.729 0.313,0.167 10 false VA8 2.021,3.552 2.385,3.719 0.365,0.167 10 false VA11 3.021,2.667 3.323,2.865 0.302,0.198 10 false VA7 1.625,2.771 2.021,2.938 0.396,0.167 10 false VA14 2.969,2.969 3.344,3.135 0.375,0.167 10 false VA10

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 1):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z26-2 (VA7) - z26-15 (VA8) 8 Power switch off 3.0 V or more
z26-15 (VA8) - z26-11 (VA9) 9 Power switch off 3.0 V or more
z26-11 (VA9) - z26-7 (VA10) 10 Power switch off 3.0 V or more
z26-7 (VA10) - z26-16 (VA11) 11 Power switch off 3.0 V or more
z26-16 (VA11) - z26-12 (VA12) 12 Power switch off 3.0 V or more
z26-12 (VA12) - z26-8 (VA13) 13 Power switch off 3.0 V or more
z26-8 (VA13) - z26-4 (VA14) 14 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



vi.

Reconnect the z26 battery smart unit connector.


vii.

Disconnect the z27 battery smart unit connector.


viii.
U190736E02
2.146,2.854 2.146,2.333 false 2.24,2.854 2.688,2.333 false 2.24,2.906 2.688,2.906 false 2.073,2.917 1.396,2.583 false 2.083,2.979 1.406,3.313 false 2.156,2.917 2.375,3.427 false 2.156,2.979 1.708,3.5 false 2.24,2.979 2.667,3.198 false 2,3.792 2.375,3.979 0.375,0.188 10 false z27 0.177,0.104 0.344,0.271 0.167,0.167 10 false *a 1.99,2.135 2.354,2.302 0.365,0.167 10 false VA19 2.615,2.156 2.979,2.323 0.365,0.167 10 false VA16 2.719,2.833 3.083,3 0.365,0.167 10 false VA15 0.99,2.469 1.354,2.635 0.365,0.167 10 false VA21 1.021,3.271 1.385,3.438 0.365,0.167 10 false VA20 2.281,3.469 2.646,3.635 0.365,0.167 10 false VA18 1.438,3.51 1.802,3.677 0.365,0.167 10 false VA17 2.688,3.135 3.052,3.302 0.365,0.167 10 false GA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 2):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z27-11 (GA1) - z27-6 (VA15) 15 Power switch off 3.0 V or more
z27-6 (VA15) - z27-1 (VA16) 16 Power switch off 3.0 V or more
z27-1 (VA16) - z27-12 (VA17) 17 Power switch off 3.0 V or more
z27-12 (VA17) - z27-7 (VA18) 18 Power switch off 3.0 V or more
z27-7 (VA18) - z27-2 (VA19) 19 Power switch off 3.0 V or more
z27-2 (VA19) - z27-13 (VA20) 20 Power switch off 3.0 V or more
z27-13 (VA20) - z27-8 (VA21) 21 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



ix.
U190737E02
2,2.844 2,2.323 false 2.083,2.833 2.531,2.313 false 2,2.917 2.583,3.26 false 1.917,2.844 1.469,2.323 false 1.917,2.917 1.24,2.583 false 1.927,2.979 1.25,3.313 false 2.083,2.917 2.729,2.698 false 2,2.979 1.552,3.5 false 2.01,3.792 2.479,3.979 0.469,0.188 10 false z27 0.198,0.135 0.365,0.302 0.167,0.167 10 false *a 1.854,2.135 2.219,2.302 0.365,0.167 10 false VA25 2.458,2.135 2.823,2.302 0.365,0.167 10 false VA22 2.625,3.219 2.99,3.385 0.365,0.167 10 false VA24 1.167,2.156 1.531,2.323 0.365,0.167 10 false VA28 0.844,2.458 1.208,2.625 0.365,0.167 10 false VA27 0.844,3.26 1.208,3.427 0.365,0.167 10 false VA26 2.76,2.573 3.198,2.792 0.438,0.219 10 false VA21 1.281,3.521 1.646,3.688 0.365,0.167 10 false VA23

Measure the voltage according to the value(s) in the table below .

Standard Voltage (Battery Block 3):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z27-8 (VA21) - z27-3 (VA22) 22 Power switch off 3.0 V or more
z27-3 (VA22) - z27-14 (VA23) 23 Power switch off 3.0 V or more
z27-14 (VA23) - z27-9 (VA24) 24 Power switch off 3.0 V or more
z27-9 (VA24) - z27-4 (VA25) 25 Power switch off 3.0 V or more
z27-4 (VA25) - z27-15 (VA26) 26 Power switch off 3.0 V or more
z27-15 (VA26) - z27-10 (VA27) 27 Power switch off 3.0 V or more
z27-10 (VA27) - z27-5 (VA28) 28 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



x.

Reconnect the z27 battery smart unit connector.


xi.

Disconnect the z22 battery smart unit connector.


xii.
U190732E02
1.698,2.844 1.958,2.542 false 1.542,2.906 0.865,2.781 false 1.542,2.979 0.865,3.25 false 1.625,2.906 2.104,2.813 false 1.615,2.979 1.167,3.5 false 1.698,2.917 2.115,3.188 false 1.604,2.844 1.167,2.469 false 1.698,2.969 1.865,3.448 false 1.448,2.094 1.75,2.281 0.302,0.188 10 false z22 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 0.792,2.354 1.156,2.521 0.365,0.167 10 false VA33 1.979,2.396 2.344,2.563 0.365,0.167 10 false VA30 2.135,3.135 2.5,3.302 0.365,0.167 10 false VA29 0.479,2.688 0.844,2.854 0.365,0.167 10 false VA35 0.469,3.188 0.833,3.354 0.365,0.167 10 false VA34 2.125,2.698 2.49,2.865 0.365,0.167 10 false VA32 0.875,3.51 1.24,3.677 0.365,0.167 10 false VA31 1.792,3.469 2.156,3.635 0.365,0.167 10 false GA2

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 4):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z22-11 (GA2) - z22-6 (VA29) 29 Power switch off 3.0 V or more
z22-6 (VA29) - z22-1 (VA30) 30 Power switch off 3.0 V or more
z22-1 (VA30) - z22-12 (VA31) 31 Power switch off 3.0 V or more
z22-12 (VA31) - z22-7 (VA32) 32 Power switch off 3.0 V or more
z22-7 (VA32) - z22-2 (VA33) 33 Power switch off 3.0 V or more
z22-2 (VA33) - z22-13 (VA34) 34 Power switch off 3.0 V or more
z22-13 (VA34) - z22-8 (VA35) 35 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xiii.
U190733E02
1.385,2.906 0.813,2.792 false 1.458,2.917 1.26,3.292 false 1.469,2.979 1.906,3.365 false 1.542,2.917 2.01,3.104 false 1.542,2.844 2.146,2.677 false 1.385,2.979 0.885,3.094 false 1.385,2.844 1.01,2.552 false 1.469,2.844 1.958,2.458 false 1.448,2.094 1.792,2.281 0.344,0.188 10 false z22 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 2.208,2.594 2.573,2.76 0.365,0.167 10 false VA36 2.052,3.052 2.479,3.24 0.427,0.188 10 false VA35 0.615,2.427 0.979,2.594 0.365,0.167 10 false VA42 0.406,2.719 0.771,2.885 0.365,0.167 10 false VA41 0.479,3.031 0.844,3.198 0.365,0.167 10 false VA40 1.042,3.313 1.406,3.479 0.365,0.167 10 false VA38 1.938,3.333 2.302,3.5 0.365,0.167 10 false VA37 1.99,2.365 2.354,2.563 0.365,0.198 10 false VA39

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 5):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z22-8 (VA35) - z22-3 (VA36) 36 Power switch off 3.0 V or more
z22-3 (VA36) - z22-14 (VA37) 37 Power switch off 3.0 V or more
z22-14 (VA37) - z22-9 (VA38) 38 Power switch off 3.0 V or more
z22-9 (VA38) - z22-4 (VA39) 39 Power switch off 3.0 V or more
z22-4 (VA39) - z22-15 (VA40) 40 Power switch off 3.0 V or more
z22-15 (VA40) - z22-10 (VA41) 41 Power switch off 3.0 V or more
z22-10 (VA41) - z22-5 (VA42) 42 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xiv.

Reconnect the z22 battery smart unit connector.


xv.

Disconnect the z23 battery smart unit connector.


xvi.
U190728E02
1.042,3.146 0.698,3.521 false 1.042,3.073 0.5,3.313 false 1.125,3 1.563,3.135 false 1.135,2.938 1.656,2.823 false 1.042,3.01 0.583,3.01 false 1.031,2.948 0.604,2.729 false 1.135,3.083 1.552,3.406 false 1.115,3.135 1.25,3.563 false 0.896,2.198 1.24,2.385 0.344,0.188 10 false z23 0.167,0.188 0.333,0.354 0.167,0.167 10 false *a 1.677,2.74 2.042,2.906 0.365,0.167 10 false VA45 1.625,3.083 1.99,3.25 0.365,0.167 10 false VA44 0.188,2.927 0.552,3.094 0.365,0.167 10 false VA48 1.583,3.375 1.948,3.542 0.365,0.167 10 false VA43 0.5,3.542 0.865,3.708 0.365,0.167 10 false VA46 0.115,3.24 0.479,3.406 0.365,0.167 10 false VA47 0.219,2.604 0.583,2.802 0.365,0.198 10 false VA49 1.156,3.573 1.521,3.74 0.365,0.167 10 false GA3

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 6):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z23-13 (GA3) - z23-9 (VA43) 43 Power switch off 3.0 V or more
z23-9 (VA43) - z23-5 (VA44) 44 Power switch off 3.0 V or more
z23-5 (VA44) - z23-1 (VA45) 45 Power switch off 3.0 V or more
z23-1 (VA45) - z23-14 (VA46) 46 Power switch off 3.0 V or more
z23-14 (VA46) - z23-10 (VA47) 47 Power switch off 3.0 V or more
z23-10 (VA47) - z23-6 (VA48) 48 Power switch off 3.0 V or more
z23-6 (VA48) - z23-2 (VA49) 49 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xvii.
U190729E02
0.875,3 0.615,2.854 false 0.885,3.146 0.625,3.375 false 0.969,3.135 0.854,3.656 false 0.969,3.083 1.406,3.396 false 0.885,3.073 0.573,3.135 false 0.896,2.948 1.438,2.604 false 0.969,3.01 1.521,3.104 false 1.052,2.938 1.458,2.865 false 0.917,2.188 1.24,2.375 0.323,0.188 10 false z23 0.177,0.177 0.344,0.344 0.167,0.167 10 false *a 1.438,3.396 1.802,3.573 0.365,0.177 10 false VA51 1.479,2.479 1.844,2.646 0.365,0.167 10 false VA56 0.229,2.75 0.594,2.917 0.365,0.167 10 false VA55 0.177,3.073 0.542,3.24 0.365,0.167 10 false VA54 0.271,3.323 0.635,3.49 0.365,0.167 10 false VA53 0.677,3.667 1.042,3.833 0.365,0.167 10 false VA50 1.573,3.042 1.938,3.24 0.365,0.198 10 false VA52 1.5,2.771 1.865,2.938 0.365,0.167 10 false VA49

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 7):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z23-2 (VA49) - z23-15 (VA50) 50 Power switch off 3.0 V or more
z23-15 (VA50) - z23-11 (VA51) 51 Power switch off 3.0 V or more
z23-11 (VA51) - z23-7 (VA52) 52 Power switch off 3.0 V or more
z23-7 (VA52) - z23-16 (VA53) 53 Power switch off 3.0 V or more
z23-16 (VA53) - z23-12 (VA54) 54 Power switch off 3.0 V or more
z23-12 (VA54) - z23-8 (VA55) 55 Power switch off 3.0 V or more
z23-8 (VA55) - z23-4 (VA56) 56 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.


Result:
Result Proceed to
The difference between the highest and lowest value is less than 0.3 V and every measured value is 3.0 V or more. A
Other than above. B



xviii.

Reconnect the z23 battery smart unit connector.


xix.

Install the No. 1 hybrid battery shield sub-assembly.



b.

2013/12 -:

i.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



ii.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


iii.

Disconnect the z32 battery smart unit connector.


iv.
U190742E02
2.729,3.135 2.354,3.531 true 2.74,3 2.969,3.146 true 2.74,2.938 2.99,2.865 true 2.656,3.135 2.094,3.385 true 2.646,3 2.042,2.854 true 2.646,2.938 2.25,2.594 true 2.656,3.063 2.083,3.125 true 2.75,3.073 2.969,3.375 true 2.531,2.167 2.948,2.354 0.417,0.188 10 false z32 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 3.021,2.771 3.385,2.938 0.365,0.167 10 false VA3 2.99,3.063 3.354,3.229 0.365,0.167 10 false VA2 1.74,2.75 2.052,2.917 0.313,0.167 10 false VA6 1.771,3.052 2.063,3.219 0.292,0.167 10 false VA5 1.781,3.333 2.094,3.5 0.313,0.167 10 false VA4 2.198,3.542 2.563,3.708 0.365,0.167 10 false GA0 1.927,2.469 2.229,2.667 0.302,0.198 10 false VA7 2.938,3.375 3.302,3.542 0.365,0.167 10 false VA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 0):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z32-13 (GA0) - z32-9 (VA1) 1 Power switch off 3.0 V or more
z32-9 (VA1) -z32-5 (VA2) 2 Power switch off 3.0 V or more
z32-5 (VA2) - z32-1 (VA3) 3 Power switch off 3.0 V or more
z32-1 (VA3) - z32-14 (VA4) 4 Power switch off 3.0 V or more
z32-14 (VA4) - z32-10 (VA5) 5 Power switch off 3.0 V or more
z32-10 (VA5) - z32-6 (VA6) 6 Power switch off 3.0 V or more
z32-6 (VA6) - z32-2 (VA7) 7 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



v.
U190743E02
2.51,3.135 2.229,3.531 true 2.604,3.073 2.938,3.281 true 2.5,3.063 2.052,3.333 true 2.667,2.938 2.979,2.771 true 2.594,3.135 2.865,3.51 true 2.51,2.938 2.021,2.875 true 2.51,3 1.938,3.125 true 2.594,3 2.927,3.021 true 2.542,2.167 2.927,2.354 0.385,0.188 10 false z32 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 2.958,3.229 3.323,3.396 0.365,0.167 10 false VA9 1.542,3.042 1.938,3.208 0.396,0.167 10 false VA13 1.646,3.292 2.021,3.458 0.375,0.167 10 false VA12 2.781,3.542 3.094,3.708 0.313,0.167 10 false VA8 2.021,3.542 2.385,3.708 0.365,0.167 10 false VA11 3.01,2.677 3.313,2.875 0.302,0.198 10 false VA7 1.635,2.781 2.031,2.948 0.396,0.167 10 false VA14 2.969,2.948 3.344,3.115 0.375,0.167 10 false VA10

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 1):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z32-2 (VA7) - z32-15 (VA8) 8 Power switch off 3.0 V or more
z32-15 (VA8) - z32-11 (VA9) 9 Power switch off 3.0 V or more
z32-11 (VA9) - z32-7 (VA10) 10 Power switch off 3.0 V or more
z32-7 (VA10) - z32-16 (VA11) 11 Power switch off 3.0 V or more
z32-16 (VA11) - z32-12 (VA12) 12 Power switch off 3.0 V or more
z32-12 (VA12) - z32-8 (VA13) 13 Power switch off 3.0 V or more
z32-8 (VA13) - z32-4 (VA14) 14 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



vi.

Reconnect the z32 battery smart unit connector.


vii.

Disconnect the z33 battery smart unit connector.


viii.
U190738E02
2.156,2.833 2.156,2.313 true 2.24,2.844 2.688,2.323 true 2.24,2.906 2.688,2.906 true 2.083,2.844 1.406,2.51 false 2.073,2.844 1.396,2.51 true 2.083,2.906 1.406,3.24 false 2.083,2.906 1.406,3.24 true 2.156,2.906 2.375,3.417 true 2.146,2.979 1.698,3.5 true 2.24,2.969 2.667,3.188 true 2,3.802 2.375,3.99 0.375,0.188 10 false z33 0.177,0.104 0.344,0.271 0.167,0.167 10 false *a 2,2.125 2.365,2.292 0.365,0.167 10 false VA19 2.615,2.146 2.979,2.313 0.365,0.167 10 false VA16 2.719,2.844 3.083,3.01 0.365,0.167 10 false VA15 1.01,2.417 1.375,2.583 0.365,0.167 10 false VA21 1.031,3.177 1.396,3.344 0.365,0.167 10 false VA20 2.26,3.438 2.625,3.604 0.365,0.167 10 false VA18 1.448,3.531 1.813,3.698 0.365,0.167 10 false VA17 2.708,3.135 3.073,3.302 0.365,0.167 10 false GA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 2):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z33-11 (GA1) - z33-6 (VA15) 15 Power switch off 3.0 V or more
z33-6 (VA15) - z33-1 (VA16) 16 Power switch off 3.0 V or more
z33-1 (VA16) - z33-12 (VA17) 17 Power switch off 3.0 V or more
z33-12 (VA17) - z33-7 (VA18) 18 Power switch off 3.0 V or more
z33-7 (VA18) - z33-2 (VA19) 19 Power switch off 3.0 V or more
z33-2 (VA19) - z33-13 (VA20) 20 Power switch off 3.0 V or more
z33-13 (VA20) - z33-8 (VA21) 21 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



ix.
U190739E02
2,2.833 2,2.313 true 2.094,2.844 2.542,2.323 true 2,2.927 2.583,3.271 true 1.917,2.844 1.469,2.323 true 1.927,2.906 1.25,2.573 true 1.917,2.969 1.24,3.302 true 2.083,2.906 2.729,2.688 true 2,2.969 1.552,3.49 true 2.01,3.802 2.479,3.99 0.469,0.188 10 false z33 0.177,0.104 0.344,0.271 0.167,0.167 10 false *a 1.833,2.094 2.198,2.26 0.365,0.167 10 false VA25 2.458,2.125 2.823,2.292 0.365,0.167 10 false VA22 2.625,3.198 2.99,3.365 0.365,0.167 10 false VA24 1.188,2.125 1.552,2.292 0.365,0.167 10 false VA28 0.875,2.458 1.24,2.625 0.365,0.167 10 false VA27 0.875,3.281 1.24,3.448 0.365,0.167 10 false VA26 2.76,2.552 3.198,2.771 0.438,0.219 10 false VA21 1.271,3.51 1.635,3.677 0.365,0.167 10 false VA23

Measure the voltage according to the value(s) in the table below .

Standard Voltage (Battery Block 3):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z33-8 (VA21) - z33-3 (VA22) 22 Power switch off 3.0 V or more
z33-3 (VA22) - z33-14 (VA23) 23 Power switch off 3.0 V or more
z33-14 (VA23) - z33-9 (VA24) 24 Power switch off 3.0 V or more
z33-9 (VA24) - z33-4 (VA25) 25 Power switch off 3.0 V or more
z33-4 (VA25) - z33-15 (VA26) 26 Power switch off 3.0 V or more
z33-15 (VA26) - z33-10 (VA27) 27 Power switch off 3.0 V or more
z33-10 (VA27) - z33-5 (VA28) 28 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



x.

Reconnect the z33 battery smart unit connector.


xi.

Disconnect the z30 battery smart unit connector.


xii.
U190734E02
1.698,2.844 1.958,2.542 true 1.542,2.906 0.865,2.781 true 1.531,2.969 0.854,3.24 true 1.615,2.896 2.094,2.802 true 1.615,2.979 1.167,3.5 true 1.698,2.906 2.115,3.177 true 1.625,2.833 1.188,2.458 true 1.698,2.979 1.865,3.458 true 1.458,2.115 1.76,2.302 0.302,0.188 10 false z30 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 0.833,2.344 1.198,2.51 0.365,0.167 10 false VA33 1.979,2.406 2.344,2.573 0.365,0.167 10 false VA30 2.135,3.135 2.5,3.302 0.365,0.167 10 false VA29 0.479,2.656 0.844,2.823 0.365,0.167 10 false VA35 0.49,3.167 0.854,3.333 0.365,0.167 10 false VA34 2.125,2.698 2.49,2.865 0.365,0.167 10 false VA32 0.906,3.5 1.271,3.667 0.365,0.167 10 false VA31 1.792,3.479 2.156,3.646 0.365,0.167 10 false GA2

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 4):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z30-11 (GA2) - z30-6 (VA29) 29 Power switch off 3.0 V or more
z30-6 (VA29) - z30-1 (VA30) 30 Power switch off 3.0 V or more
z30-1 (VA30) - z30-12 (VA31) 31 Power switch off 3.0 V or more
z30-12 (VA31) - z30-7 (VA32) 32 Power switch off 3.0 V or more
z30-7 (VA32) - z30-2 (VA33) 33 Power switch off 3.0 V or more
z30-2 (VA33) - z30-13 (VA34) 34 Power switch off 3.0 V or more
z30-13 (VA34) - z30-8 (VA35) 35 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xiii.
U190735E02
1.375,2.896 0.802,2.781 true 1.469,2.906 1.271,3.281 true 1.469,2.979 1.906,3.365 true 1.552,2.906 2.021,3.094 true 1.552,2.844 2.156,2.677 true 1.375,2.969 0.875,3.083 true 1.375,2.833 1,2.542 true 1.469,2.844 1.958,2.458 true 1.458,2.104 1.802,2.292 0.344,0.188 10 false z30 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 2.208,2.583 2.573,2.75 0.365,0.167 10 false VA36 2.073,3.021 2.5,3.208 0.427,0.188 10 false VA35 0.615,2.417 0.979,2.583 0.365,0.167 10 false VA42 0.417,2.688 0.781,2.854 0.365,0.167 10 false VA41 0.5,3.01 0.865,3.177 0.365,0.167 10 false VA40 1.052,3.292 1.417,3.458 0.365,0.167 10 false VA38 1.948,3.323 2.313,3.49 0.365,0.167 10 false VA37 2,2.354 2.365,2.552 0.365,0.198 10 false VA39

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 5):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z30-8 (VA35) - z30-3 (VA36) 36 Power switch off 3.0 V or more
z30-3 (VA36) - z30-14 (VA37) 37 Power switch off 3.0 V or more
z30-14 (VA37) - z30-9 (VA38) 38 Power switch off 3.0 V or more
z30-9 (VA38) - z30-4 (VA39) 39 Power switch off 3.0 V or more
z30-4 (VA39) - z30-15 (VA40) 40 Power switch off 3.0 V or more
z30-15 (VA40) - z30-10 (VA41) 41 Power switch off 3.0 V or more
z30-10 (VA41) - z30-5 (VA42) 42 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xiv.

Reconnect the z30 battery smart unit connector.


xv.

Disconnect the z31 battery smart unit connector.


xvi.
U190730E02
1.031,3.135 0.688,3.51 true 1.031,3.063 0.49,3.302 true 1.135,3.01 1.573,3.146 true 1.125,2.938 1.646,2.823 true 1.042,3.01 0.583,3.01 true 1.031,2.938 0.604,2.719 true 1.125,3.073 1.542,3.396 true 1.125,3.135 1.26,3.563 true 0.906,2.208 1.25,2.396 0.344,0.188 10 false z31 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 1.688,2.719 2.052,2.885 0.365,0.167 10 false VA45 1.635,3.073 2,3.24 0.365,0.167 10 false VA44 0.208,2.927 0.573,3.094 0.365,0.167 10 false VA48 1.583,3.344 1.948,3.51 0.365,0.167 10 false VA43 0.479,3.531 0.844,3.698 0.365,0.167 10 false VA46 0.125,3.24 0.49,3.406 0.365,0.167 10 false VA47 0.24,2.615 0.604,2.813 0.365,0.198 10 false VA49 1.135,3.573 1.5,3.74 0.365,0.167 10 false GA3

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 6):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z31-13 (GA3) - z31-9 (VA43) 43 Power switch off 3.0 V or more
z31-9 (VA43) - z31-5 (VA44) 44 Power switch off 3.0 V or more
z31-5 (VA44) - z31-1 (VA45) 45 Power switch off 3.0 V or more
z31-1 (VA45) - z31-14 (VA46) 46 Power switch off 3.0 V or more
z31-14 (VA46) - z31-10 (VA47) 47 Power switch off 3.0 V or more
z31-10 (VA47) - z31-6 (VA48) 48 Power switch off 3.0 V or more
z31-6 (VA48) - z31-2 (VA49) 49 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



xvii.
U190731E02
0.885,3 0.625,2.854 true 0.885,3.135 0.625,3.365 true 0.969,3.135 0.854,3.656 true 0.979,3.073 1.417,3.385 true 0.875,3.073 0.563,3.135 true 0.896,2.938 1.438,2.594 true 0.969,3.01 1.521,3.104 true 1.052,2.948 1.458,2.875 true 0.917,2.198 1.24,2.385 0.323,0.188 10 false z31 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 1.406,3.406 1.771,3.583 0.365,0.177 10 false VA51 1.469,2.49 1.833,2.656 0.365,0.167 10 false VA56 0.25,2.771 0.615,2.938 0.365,0.167 10 false VA55 0.188,3.063 0.552,3.229 0.365,0.167 10 false VA54 0.271,3.354 0.635,3.521 0.365,0.167 10 false VA53 0.667,3.667 1.031,3.833 0.365,0.167 10 false VA50 1.552,3.042 1.917,3.24 0.365,0.198 10 false VA52 1.49,2.771 1.854,2.938 0.365,0.167 10 false VA49

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 7):
Tester Connection Hybrid Battery Cell Switch Condition Specified Condition
z31-2 (VA49) - z31-15 (VA50) 50 Power switch off 3.0 V or more
z31-15 (VA50) - z31-11 (VA51) 51 Power switch off 3.0 V or more
z31-11 (VA51) - z31-7 (VA52) 52 Power switch off 3.0 V or more
z31-7 (VA52) - z31-16 (VA53) 53 Power switch off 3.0 V or more
z31-16 (VA53) - z31-12 (VA54) 54 Power switch off 3.0 V or more
z31-12 (VA54) - z31-8 (VA55) 55 Power switch off 3.0 V or more
z31-8 (VA55) - z31-4 (VA56) 56 Power switch off 3.0 V or more


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.


Result:
Result Proceed to
The difference between the highest and lowest value is less than 0.3 V and every measured value is 3.0 V or more. A
Other than above. B



xviii.

Reconnect the z31 battery smart unit connector.


xix.

Install the No. 1 hybrid battery shield sub-assembly.




A

B

12.CHECK BATTERY SMART UNIT
12.CHECK BATTERY SMART UNIT
NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance.


a.

2012/05 - 2013/12:


ii.

Measure the resistance according to the value(s) in the table below.

HINT:
·

If the voltage of any cell of the HV battery was less than 3.0 V, measure the resistance of the battery smart unit at the terminals which relate to that battery cell.

·

If the difference between the highest and lowest measured cell voltage of each battery block is 0.3 V or more, measure the resistance of the battery smart unit at the terminals which relate to the cell with the lowest measured voltage.



A417508C02
1.156,2.229 1.594,2.521 0.438,0.292 1.885,2.229 2.323,2.521 0.438,0.292 2.563,2.24 3,2.531 0.438,0.292 3.271,2.25 3.708,2.542 0.438,0.292 0.344,0.115 1,0.729 0.656,0.615 10 false *a 1.271,2.271 1.854,2.615 0.583,0.344 10 false z23 2.01,2.271 2.594,2.615 0.583,0.344 10 false z22 2.667,2.281 3.25,2.625 0.583,0.344 10 false z27 3.385,2.302 3.969,2.646 0.583,0.344 10 false z26
*a Component without harness connected
(Battery Smart Unit)
- -


Standard Resistance (Battery Block 0):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z26-13 (GA0) (-) - z26-9 (VA1) (+) 1 Always 50 kΩ or higher
z26-9 (VA1) (-) - z26-5 (VA2) (+) 2 Always 50 kΩ or higher
z26-5 (VA2) (-) - z26-1 (VA3) (+) 3 Always 50 kΩ or higher
z26-1 (VA3) (-) - z26-14 (VA4) (+) 4 Always 50 kΩ or higher
z26-14 (VA4) (-) - z26-10 (VA5) (+) 5 Always 50 kΩ or higher
z26-10 (VA5) (-) - z26-6 (VA6) (+) 6 Always 50 kΩ or higher
z26-6 (VA6) (-) - z26-2 (VA7) (+) 7 Always 50 kΩ or higher
z26-13 (GA0) (-) -z26-2 (VA7) (+)
·

1

·

2

·

3

·

4

·

5

·

6

·

7


Always 350 kΩ or higher


Standard Resistance (Battery Block 1):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z26-2 (VA7) (-) - z26-15 (VA8) (+) 8 Always 50 kΩ or higher
z26-15 (VA8) (-) - z26-11 (VA9) (+) 9 Always 50 kΩ or higher
z26-11 (VA9) (-) - z26-7 (VA10) (+) 10 Always 50 kΩ or higher
z26-7 (VA10) (-) - z26-16 (VA11) (+) 11 Always 50 kΩ or higher
z26-16 (VA11) (-) - z26-12 (VA12) (+) 12 Always 50 kΩ or higher
z26-12 (VA12) (-) - z26-8 (VA13) (+) 13 Always 50 kΩ or higher
z26-8 (VA13) (-) - z26-4 (VA14) (+) 14 Always 50 kΩ or higher
z26-2 (VA7) (-) - z26-4 (VA14) (+)
·

8

·

9

·

10

·

11

·

12

·

13

·

14


Always 350 kΩ or higher


Standard Resistance (Battery Block 2):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z27-11 (GA1) (-) - z27-6 (VA15) (+) 15 Always 50 kΩ or higher
z27-6 (VA15) (-) - z27-1 (VA16) (+) 16 Always 50 kΩ or higher
z27-1 (VA16) (-) - z27-12 (VA17) (+) 17 Always 50 kΩ or higher
z27-12 (VA17) (-) - z27-7 (VA18) (+) 18 Always 50 kΩ or higher
z27-7 (VA18) (-) - z27-2 (VA19) (+) 19 Always 50 kΩ or higher
z27-2 (VA19) (-) - z27-13 (VA20) (+) 20 Always 50 kΩ or higher
z27-13 (VA20) (-) - z27-8 (VA21) (+) 21 Always 50 kΩ or higher
z27-11 (GA1) (-) - z27-8 (VA21) (+)
·

15

·

16

·

17

·

18

·

19

·

20

·

21


Always 350 kΩ or higher


Standard Resistance (Battery Block 3):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z27-8 (VA21) (-) - z27-3 (VA22) (+) 22 Always 50 kΩ or higher
z27-3 (VA22) (-) - z27-14 (VA23) (+) 23 Always 50 kΩ or higher
z27-14 (VA23) (-) - z27-9 (VA24) (+) 24 Always 50 kΩ or higher
z27-9 (VA24) (-) - z27-4 (VA25) (+) 25 Always 50 kΩ or higher
z27-4 (VA25) (-) - z27-15 (VA26) (+) 26 Always 50 kΩ or higher
z27-15 (VA26) (-) - z27-10 (VA27) (+) 27 Always 50 kΩ or higher
z27-10 (VA27) (-) - z27-5 (VA28) (+) 28 Always 50 kΩ or higher
z27-8 (VA21) (-) - z27-5 (VA28) (+)
·

22

·

23

·

24

·

25

·

26

·

27

·

28


Always 350 kΩ or higher


Standard Resistance (Battery Block 4):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z22-11 (GA2) (-) - z22-6 (VA29) (+) 29 Always 50 kΩ or higher
z22-6 (VA29) (-) - z22-1 (VA30) (+) 30 Always 50 kΩ or higher
z22-1 (VA30) (-) - z22-12 (VA31) (+) 31 Always 50 kΩ or higher
z22-12 (VA31) (-) - z22-7 (VA32) (+) 32 Always 50 kΩ or higher
z22-7 (VA32) (-) - z22-2 (VA33) (+) 33 Always 50 kΩ or higher
z22-2 (VA33) (-) - z22-13 (VA34) (+) 34 Always 50 kΩ or higher
z22-13 (VA34) (-) - z22-8 (VA35) (+) 35 Always 50 kΩ or higher
z22-11 (GA2) (-) - z22-8 (VA35) (+)
·

29

·

30

·

31

·

32

·

33

·

34

·

35


Always 350 kΩ or higher


Standard Resistance (Battery Block 5):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z22-8 (VA35) (-) - z22-3 (VA36) (+) 36 Always 50 kΩ or higher
z22-3 (VA36) (-) - z22-14 (VA37) (+) 37 Always 50 kΩ or higher
z22-14 (VA37) (-) - z22-9 (VA38) (+) 38 Always 50 kΩ or higher
z22-9 (VA38) (-) - z22-4 (VA39) (+) 39 Always 50 kΩ or higher
z22-4 (VA39) (-) - z22-15 (VA40) (+) 40 Always 50 kΩ or higher
z22-15 (VA40) (-) - z22-10 (VA41) (+) 41 Always 50 kΩ or higher
z22-10 (VA41) (-) - z22-5 (VA42) (+) 42 Always 50 kΩ or higher
z22-8 (VA35) (-) - z22-5 (VA42) (+)
·

36

·

37

·

38

·

39

·

40

·

41

·

42


Always 350 kΩ or higher


Standard Resistance (Battery Block 6):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z23-13 (GA3) (-) - z23-9 (VA43) (+) 43 Always 50 kΩ or higher
z23-9 (VA43) (-) - z23-5 (VA44) (+) 44 Always 50 kΩ or higher
z23-5 (VA44) (-) - z23-1 (VA45) (+) 45 Always 50 kΩ or higher
z23-1 (VA45) (-) - z23-14 (VA46) (+) 46 Always 50 kΩ or higher
z23-14 (VA46) (-) - z23-10 (VA47) (+) 47 Always 50 kΩ or higher
z23-10 (VA47) (-) - z23-6 (VA48) (+) 48 Always 50 kΩ or higher
z23-6 (VA48) (-) - z23-2 (VA49) (+) 49 Always 50 kΩ or higher
z23-13 (GA3) (-) - z23-2 (VA49) (+)
·

43

·

44

·

45

·

46

·

47

·

48

·

49


Always 350 kΩ or higher


Standard Resistance (Battery Block 7):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z23-2 (VA49) (-) - z23-15 (VA50) (+) 50 Always 50 kΩ or higher
z23-15 (VA50) (-) - z23-11 (VA51) (+) 51 Always 50 kΩ or higher
z23-11 (VA51) (-) - z23-7 (VA52) (+) 52 Always 50 kΩ or higher
z23-7 (VA52) (-) - z23-16 (VA53) (+) 53 Always 50 kΩ or higher
z23-16 (VA53) (-) - z23-12 (VA54) (+) 54 Always 50 kΩ or higher
z23-12 (VA54) (-) - z23-8 (VA55) (+) 55 Always 50 kΩ or higher
z23-8 (VA55) (-) - z23-4 (VA56) (+) 56 Always 50 kΩ or higher
z23-2 (VA49) (-) - z23-4 (VA56) (+)
·

50

·

51

·

52

·

53

·

54

·

55

·

56


Always 350 kΩ or higher


NOTICE:
·

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.

·

Read the resistance after the value has stabilized.

·

In order to avoid damaging the terminals of the battery smart unit, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery smart unit.




iii.

Install the battery smart unit.

Result:
Result Proceed to
All measured values were within specified range. A
Other than above. B




b.

2013/12 -:


ii.

Measure the resistance according to the value(s) in the table below.

HINT:
·

If the voltage of any cell of the HV battery was less than 3.0 V, measure the resistance of the battery smart unit at the terminals which relate to that battery cell.

·

If the difference between the highest and lowest measured cell voltage of each battery block is 0.3 V or more, measure the resistance of the battery smart unit at the terminals which relate to the cell with the lowest measured voltage.



A417508C03
1.156,2.229 1.594,2.521 0.438,0.292 1.885,2.229 2.323,2.521 0.438,0.292 2.563,2.24 3,2.531 0.438,0.292 3.271,2.25 3.708,2.542 0.438,0.292 0.344,0.115 1,0.729 0.656,0.615 10 false *a 1.271,2.271 1.854,2.615 0.583,0.344 10 false z31 2.01,2.271 2.594,2.615 0.583,0.344 10 false z30 2.667,2.281 3.25,2.625 0.583,0.344 10 false z33 3.365,2.302 3.948,2.646 0.583,0.344 10 false z32
*a Component without harness connected
(Battery Smart Unit)
- -


Standard Resistance (Battery Block 0):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z32-13 (GA0) (-) - z32-9 (VA1) (+) 1 Always 50 kΩ or higher
z32-9 (VA1) (-) - z32-5 (VA2) (+) 2 Always 50 kΩ or higher
z32-5 (VA2) (-) - z32-1 (VA3) (+) 3 Always 50 kΩ or higher
z32-1 (VA3) (-) - z32-14 (VA4) (+) 4 Always 50 kΩ or higher
z32-14 (VA4) (-) - z32-10 (VA5) (+) 5 Always 50 kΩ or higher
z32-10 (VA5) (-) - z32-6 (VA6) (+) 6 Always 50 kΩ or higher
z32-6 (VA6) (-) - z32-2 (VA7) (+) 7 Always 50 kΩ or higher
z32-13 (GA0) (-) -z32-2 (VA7) (+)
·

1

·

2

·

3

·

4

·

5

·

6

·

7


Always 350 kΩ or higher


Standard Resistance (Battery Block 1):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z32-2 (VA7) (-) - z32-15 (VA8) (+) 8 Always 50 kΩ or higher
z32-15 (VA8) (-) - z32-11 (VA9) (+) 9 Always 50 kΩ or higher
z32-11 (VA9) (-) - z32-7 (VA10) (+) 10 Always 50 kΩ or higher
z32-7 (VA10) (-) - z32-16 (VA11) (+) 11 Always 50 kΩ or higher
z32-16 (VA11) (-) - z32-12 (VA12) (+) 12 Always 50 kΩ or higher
z32-12 (VA12) (-) - z32-8 (VA13) (+) 13 Always 50 kΩ or higher
z32-8 (VA13) (-) - z32-4 (VA14) (+) 14 Always 50 kΩ or higher
z32-2 (VA7) (-) - z32-4 (VA14) (+)
·

8

·

9

·

10

·

11

·

12

·

13

·

14


Always 350 kΩ or higher


Standard Resistance (Battery Block 2):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z33-11 (GA1) (-) - z33-6 (VA15) (+) 15 Always 50 kΩ or higher
z33-6 (VA15) (-) - z33-1 (VA16) (+) 16 Always 50 kΩ or higher
z33-1 (VA16) (-) - z33-12 (VA17) (+) 17 Always 50 kΩ or higher
z33-12 (VA17) (-) - z33-7 (VA18) (+) 18 Always 50 kΩ or higher
z33-7 (VA18) (-) - z33-2 (VA19) (+) 19 Always 50 kΩ or higher
z33-2 (VA19) (-) - z33-13 (VA20) (+) 20 Always 50 kΩ or higher
z33-13 (VA20) (-) - z33-8 (VA21) (+) 21 Always 50 kΩ or higher
z33-11 (GA1) (-) - z33-8 (VA21) (+)
·

15

·

16

·

17

·

18

·

19

·

20

·

21


Always 350 kΩ or higher


Standard Resistance (Battery Block 3):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z33-8 (VA21) (-) - z33-3 (VA22) (+) 22 Always 50 kΩ or higher
z33-3 (VA22) (-) - z33-14 (VA23) (+) 23 Always 50 kΩ or higher
z33-14 (VA23) (-) - z33-9 (VA24) (+) 24 Always 50 kΩ or higher
z33-9 (VA24) (-) - z33-4 (VA25) (+) 25 Always 50 kΩ or higher
z33-4 (VA25) (-) - z33-15 (VA26) (+) 26 Always 50 kΩ or higher
z33-15 (VA26) (-) - z33-10 (VA27) (+) 27 Always 50 kΩ or higher
z33-10 (VA27) (-) - z33-5 (VA28) (+) 28 Always 50 kΩ or higher
z33-8 (VA21) (-) - z33-5 (VA28) (+)
·

22

·

23

·

24

·

25

·

26

·

27

·

28


Always 350 kΩ or higher


Standard Resistance (Battery Block 4):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z30-11 (GA2) (-) - z30-6 (VA29) (+) 29 Always 50 kΩ or higher
z30-6 (VA29) (-) - z30-1 (VA30) (+) 30 Always 50 kΩ or higher
z30-1 (VA30) (-) - z30-12 (VA31) (+) 31 Always 50 kΩ or higher
z30-12 (VA31) (-) - z30-7 (VA32) (+) 32 Always 50 kΩ or higher
z30-7 (VA32) (-) - z30-2 (VA33) (+) 33 Always 50 kΩ or higher
z30-2 (VA33) (-) - z30-13 (VA34) (+) 34 Always 50 kΩ or higher
z30-13 (VA34) (-) - z30-8 (VA35) (+) 35 Always 50 kΩ or higher
z30-11 (GA2) (-) - z30-8 (VA35) (+)
·

29

·

30

·

31

·

32

·

33

·

34

·

35


Always 350 kΩ or higher


Standard Resistance (Battery Block 5):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z30-8 (VA35) (-) - z30-3 (VA36) (+) 36 Always 50 kΩ or higher
z30-3 (VA36) (-) - z30-14 (VA37) (+) 37 Always 50 kΩ or higher
z30-14 (VA37) (-) - z30-9 (VA38) (+) 38 Always 50 kΩ or higher
z30-9 (VA38) (-) - z30-4 (VA39) (+) 39 Always 50 kΩ or higher
z30-4 (VA39) (-) - z30-15 (VA40) (+) 40 Always 50 kΩ or higher
z30-15 (VA40) (-) - z30-10 (VA41) (+) 41 Always 50 kΩ or higher
z30-10 (VA41) (-) - z30-5 (VA42) (+) 42 Always 50 kΩ or higher
z30-8 (VA35) (-) - z30-5 (VA42) (+)
·

36

·

37

·

38

·

39

·

40

·

41

·

42


Always 350 kΩ or higher


Standard Resistance (Battery Block 6):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z31-13 (GA3) (-) - z31-9 (VA43) (+) 43 Always 50 kΩ or higher
z31-9 (VA43) (-) - z31-5 (VA44) (+) 44 Always 50 kΩ or higher
z31-5 (VA44) (-) - z31-1 (VA45) (+) 45 Always 50 kΩ or higher
z31-1 (VA45) (-) - z31-14 (VA46) (+) 46 Always 50 kΩ or higher
z31-14 (VA46) (-) - z31-10 (VA47) (+) 47 Always 50 kΩ or higher
z31-10 (VA47) (-) - z31-6 (VA48) (+) 48 Always 50 kΩ or higher
z31-6 (VA48) (-) - z31-2 (VA49) (+) 49 Always 50 kΩ or higher
z31-13 (GA3) (-) - z31-2 (VA49) (+)
·

43

·

44

·

45

·

46

·

47

·

48

·

49


Always 350 kΩ or higher


Standard Resistance (Battery Block 7):
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z31-2 (VA49) (-) - z31-15 (VA50) (+) 50 Always 50 kΩ or higher
z31-15 (VA50) (-) - z31-11 (VA51) (+) 51 Always 50 kΩ or higher
z31-11 (VA51) (-) - z31-7 (VA52) (+) 52 Always 50 kΩ or higher
z31-7 (VA52) (-) - z31-16 (VA53) (+) 53 Always 50 kΩ or higher
z31-16 (VA53) (-) - z31-12 (VA54) (+) 54 Always 50 kΩ or higher
z31-12 (VA54) (-) - z31-8 (VA55) (+) 55 Always 50 kΩ or higher
z31-8 (VA55) (-) - z31-4 (VA56) (+) 56 Always 50 kΩ or higher
z31-2 (VA49) (-) - z31-4 (VA56) (+)
·

50

·

51

·

52

·

53

·

54

·

55

·

56


Always 350 kΩ or higher


NOTICE:
·

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.

·

Read the resistance after the value has stabilized.

·

In order to avoid damaging the terminals of the battery smart unit, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery smart unit.




iii.

Install the battery smart unit.

Result:
Result Proceed to
All measured values were within specified range. A
Other than above. B





A

B

30.REPLACE BATTERY SMART UNIT
13.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Record the output DTCs.

NOTICE:

Make a note of the DTCs that will be used in step 16.


HINT:

The DTCs will be cleared by disconnecting the cable from the negative (-) auxiliary battery terminal in steps 14 and 15.



e.

Turn the power switch off.



NEXT

14.REPLACE HV BATTERY
14.REPLACE HV BATTERY

NEXT

15.REPLACE BATTERY SMART UNIT
15.REPLACE BATTERY SMART UNIT

NEXT

16.RECONFIRM DTC OUTPUT (HYBRID CONTROL)
16.RECONFIRM DTC OUTPUT (HYBRID CONTROL)
a.

Check the DTCs recorded in step 13.

Result:
Result Proceed to
P31B3-123 is not output. A
DTCs shown in P31B3-123 and Table 1 are output simultaneously. B
DTCs shown in P31B3-123 and Table 1 are not output simultaneously. C


Table 1
DTC No. Relevant Diagnosis
P0A78-266, 267, 565, 586 Drive Motor "A" Inverter Performance
P0A94-564, 585, 587, 589, 590 DC/DC Converter Performance


HINT:

DTC P31B3-123 may be output simultaneously. In this case, troubleshoot the DTCs listed above first. Then, perform a reproduction test to check that no DTCs are output.



A

17.Utility

B

C

17.Utility
CAUTION:

Before repairing or replacing the malfunctioning part, do not perform "HV Batt Cell Low Volt READY ON Prevention Cancel".


a.

Perform "HV Batt Cell Low Volt READY ON Prevention Cancel" (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY).



NEXT

18.CLEAR DTC (HYBRID CONTROL)
18.CLEAR DTC (HYBRID CONTROL)

NEXT

19.RECONFIRM DTC OUTPUT (HYBRID CONTROL)
19.RECONFIRM DTC OUTPUT (HYBRID CONTROL)
a.

Perform a driving test for about 10 minutes to allow the ECU to store DTCs. If the hybrid system does not start, turn the power switch off and on (READY).

HINT:

Because 2-trip detection logic is used, the DTC detection conditions need to be met twice.



b.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


c.

Read output DTCs.

Result:
Result Proceed to
P31AB-123 is not output A
P31AB-123 is output B
P3004-131 is output C



d.

Turn the power switch off.



A

RETURNS TO NORMAL OPERATION

B

20.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

C

20.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

21.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY SIDE)

NG

CONNECT SECURELY

21.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY SIDE)

A

22.CHECK FRAME WIRE (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY SIDE)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

22.CHECK FRAME WIRE (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY SIDE)

A

23.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

23.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

OK

24.CHECK CONNECTOR CONNECTION CONDITION (HV BATTERY HIGH VOLTAGE CONNECTOR)

NG

24.CHECK CONNECTOR CONNECTION CONDITION (HV BATTERY HIGH VOLTAGE CONNECTOR)

A

25.CHECK HV BATTERY

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

25.CHECK HV BATTERY

OK

26.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

NG

26.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

OK

27.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

27.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

OK

28.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)

NG

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

28.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)

OK

29.CHECK FOR INTERMITTENT PROBLEMS

NG

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY