A battery current sensor, which is mounted on the positive cable side of each hybrid battery junction block assembly, detects the current flowing to or from the battery pack. The battery current sensor sends a voltage, which varies between 0 and 5 V in proportion to the amperage, to the IB0 terminal of the battery smart unit. Similarly, it sends a voltage, which varies between 0 and 5 V in inverse proportion to the amperage, into the IB1 terminal of the battery smart unit. When the voltage of the IB0 terminal is below 2.8 V and the voltage of the IB1 terminal is above 2.2 V, this indicates that the HV battery is being discharged. Meanwhile, when the voltage of the IB0 terminal is above 2.8 V and the voltage of the IB1 terminal is below 2.2 V, this indicates that the HV battery is being charged. The battery smart unit sends the signals from its IB0 and IB1 terminals to the power management control ECU. The power management control ECU determines the charging and discharging amperage of the HV battery based on the received signals and calculates the SOC of the HV battery using the cumulative amperage value.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0ABF
P0AC1 P0AC2 P0B10 P0B11 |
123 | When the battery current sensor is abnormal (1 trip detection) | ·
Hybrid battery junction block assembly ·
Battery smart unit ·
Wire harness or connector ·
HV battery |
Refer to the wiring diagram for DTC U0A29-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>U029A-123).
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
If a short to +B occurs in the battery temperature sensor, battery current sensor or intake air temperature sensor, the following DTCs may be output simultaneously.
| DTC No. | Relevant Diagnosis |
|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High |
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High |
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High |
| P0AEB-123 | Hybrid Battery Temperature Sensor "D" Circuit High |
| P0BC5-123 | Hybrid Battery Temperature Sensor "E" Circuit High |
| P0C36-123 | Hybrid Battery Temperature Sensor "F" Circuit High |
| P0AAF-123 | Hybrid Battery Pack Air Temperature Sensor "A" Circuit High |
| P0AB4-123 | Hybrid Battery Pack Air Temperature Sensor "B" Circuit High |
A
B
OK
NG
OK
NG
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| z24-11 (IB1) - z24-12 (GIB) | Power switch on (IG) | 2.16 to 2.24 V |
| z24-23 (IB0) - z24-12 (GIB) | Power switch on (IG) | 2.76 to 2.84 V |
| *a | Component with harness connected
(Battery Smart Unit) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery shield sub-assembly.
OK
NG