Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › 2012.03–2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301574 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A7F-123  Hybrid Battery Pack Deterioration  


DESCRIPTION

The battery smart unit and the power management control ECU calculate the SOC (state of charge) of the HV battery through the accumulated amperage in the HV battery. The battery smart unit sends the condition of the HV battery to the power management control ECU. Then the power management control ECU calculates the SOC based on the information and controls HV battery charge and discharge according to the driving condition.

Based on the HV battery voltage and current, the battery smart unit calculates the resistance and judges the HV battery has deteriorated.

A379359E01
2.823,1.302 2.615,0.792 2.615,0.792 2.323,0.792 false 3.521,1.208 3.521,0.396 3.521,0.396 3.76,0.396 false 3.906,1.354 4.406,0.75 4.406,0.75 4.74,0.75 false 4.51,1.969 4.229,1.969 4.229,1.969 3.813,1.396 false 3.51,2.167 3.51,1.583 false 1.333,0.698 2.302,1.01 0.969,0.313 10 false Control Region 3.854,0.313 5.854,0.719 2,0.406 10 false Upper SOC Control Limit 4.792,0.667 6.927,1 2.135,0.333 10 false Example of Change in SOC 4.573,1.885 6.906,2.354 2.333,0.469 10 false Central SOC Level 2.833,2.229 4.552,2.521 1.719,0.292 10 false Lower SOC Control Limit 2.833,1.917 3.51,2.219 0.677,0.302 10 false Time 2.052,1.208 2.729,1.51 0.677,0.302 10 false SOC

DTC No. INF Code DTC Detection Condition Trouble Area
P0A7F 123
·

Internal resistance of the HV battery is higher than the standard (1 trip detection)

·

Difference in the capacity between battery blocks is larger than the standard (2 trip detection)


·

HV battery

·

Battery smart unit



HINT:
·

P0A7F-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC. (As 2 trip detection logic is used, check for DTCs including pending DTCs.)

·

In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary:

-

Make sure the air intake port is not blocked.

-

Make sure there are no gaps between the connecting parts of the ducts.





CAUTION / NOTICE / HINT

CAUTION:
·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)

A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Read output DTCs (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).

Result:
Result Proceed to
P0AFC-123 is not output. A
P0AFC-123 is also output. B



e.

Turn the power switch off.



A

3.READ VALUE USING GTS (VB1 - VB8)

B

3.READ VALUE USING GTS (VB1 - VB8)
a.

Ensure the safety of the areas in front and at the back of the vehicle.


b.

Apply the parking brake and secure the wheels using chocks.


c.

Connect the GTS to the DLC3.


d.

Turn the power switch on (READY).


e.

Fully warm up the engine and turn the air conditioning off.


f.

Enter the following menus: Powertrain / Hybrid Control / Data List / Battery Block Vol - V01 to V08.


g.

Firmly depress the brake pedal with your left foot.


h.

Move the select lever to D.


i.

Record each battery block Voltage from the Data List (Battery Block Vol -V01 to V08) while fully depressing the accelerator pedal.


j.

Compare the battery block voltages (Battery Block Vol -V01 to V08) between the even and odd number groups in each combination shown in the table below.


Table 1
Circuit A Battery Block Circuit B Battery Block Condition
Battery Block Vol-V01 (VB1) Battery Block Vol-V02 (VB2) "Battery Block Vol - V01" - "Battery Block Vol - V02" = 0.6 V or more
Battery Block Vol-V04 (VB4) Battery Block Vol-V03 (VB3) "Battery Block Vol - V04" - "Battery Block Vol - V03" = 0.6 V or more
Battery Block Vol-V05 (VB5) Battery Block Vol-V06 (VB6) "Battery Block Vol - V05" - "Battery Block Vol - V06" = 0.6 V or more
Battery Block Vol-V08 (VB8) Battery Block Vol-V07 (VB7) "Battery Block Vol - V08" - "Battery Block Vol - V07" = 0.6 V or more

Table 2
Circuit A Battery Block Circuit B Battery Block Condition
Battery Block Vol-V01 (VB1) Battery Block Vol-V02 (VB2) "Battery Block Vol - V02" - "Battery Block Vol - V01" = 0.6 V or more
Battery Block Vol-V04 (VB4) Battery Block Vol-V03 (VB3) "Battery Block Vol - V03" - "Battery Block Vol - V04" = 0.6 V or more
Battery Block Vol-V05 (VB5) Battery Block Vol-V06 (VB6) "Battery Block Vol - V06" - "Battery Block Vol - V05" = 0.6 V or more
Battery Block Vol-V08 (VB8) Battery Block Vol-V07 (VB7) "Battery Block Vol - V07" - "Battery Block Vol - V08" = 0.6 V or more

A309350E10
0.969,2.031 1.427,2.229 0.458,0.198 10 false VB2 2.229,2.031 2.688,2.229 0.458,0.198 10 false VB3 2.583,2.031 3.042,2.229 0.458,0.198 10 false VB4 3.854,2.031 4.313,2.229 0.458,0.198 10 false VB5 4.198,2.031 4.656,2.229 0.458,0.198 10 false VB6 5.479,2.031 5.938,2.229 0.458,0.198 10 false VB7 5.833,2.031 6.292,2.229 0.458,0.198 10 false VB8 0.625,2.031 1.083,2.229 0.458,0.198 10 false VB1 0.635,4.427 1.094,4.625 0.458,0.198 10 false VB1 0.99,4.427 1.448,4.625 0.458,0.198 10 false VB2 2.25,4.427 2.708,4.625 0.458,0.198 10 false VB3 2.604,4.427 3.063,4.625 0.458,0.198 10 false VB4 3.865,4.427 4.323,4.625 0.458,0.198 10 false VB5 4.219,4.427 4.677,4.625 0.458,0.198 10 false VB6 5.479,4.427 5.938,4.625 0.458,0.198 10 false VB7 5.844,4.427 6.302,4.625 0.458,0.198 10 false VB8 1.594,3.177 1.958,3.792 0.365,0.615 10 false 0.6 V or more 3.188,3.177 3.563,3.781 0.375,0.604 10 false 0.6 V or more 4.802,3.188 5.177,3.833 0.375,0.646 10 false 0.6 V or more 6.427,3.177 6.802,3.792 0.375,0.615 10 false 0.6 V or more 6.427,0.802 6.813,1.375 0.385,0.573 10 false 0.6 V or more 4.823,0.813 5.219,1.448 0.396,0.635 10 false 0.6 V or more 3.24,0.802 3.615,1.385 0.375,0.583 10 false 0.6 V or more 1.594,0.813 1.969,1.458 0.375,0.646 10 false 0.6 V or more 0.083,0.073 4.792,0.344 4.708,0.271 10 false Example: When difference in voltage of all 4 pairs of blocks is 0.6 V or more 0.542,0.375 2.896,0.573 2.354,0.198 10 false All conditions in table 1 are met. 4.938,0.115 7.052,0.333 2.115,0.219 10 false A: Circuit A Battery Block Voltage 4.948,0.438 7.052,0.698 2.104,0.26 10 false B: Circuit B Battery Block Voltage 0.563,2.781 2.771,3.042 2.208,0.26 10 false All conditions in table 2 are met. 0.74,2.198 1.198,2.396 0.458,0.198 10 false A 2.635,2.198 3.094,2.396 0.458,0.198 10 false A 3.979,2.188 4.438,2.385 0.458,0.198 10 false A 5.875,2.198 6.333,2.396 0.458,0.198 10 false A 0.74,4.583 1.198,4.781 0.458,0.198 10 false A 2.646,4.583 3.104,4.781 0.458,0.198 10 false A 3.979,4.583 4.438,4.781 0.458,0.198 10 false A 5.885,4.583 6.344,4.781 0.458,0.198 10 false A 1.01,2.198 1.469,2.396 0.458,0.198 10 false B 2.354,2.198 2.813,2.396 0.458,0.198 10 false B 4.26,2.198 4.719,2.396 0.458,0.198 10 false B 5.594,2.208 6.052,2.406 0.458,0.198 10 false B 5.604,4.583 6.01,4.792 0.406,0.208 10 false B 4.271,4.583 4.688,4.792 0.417,0.208 10 false B 2.365,4.583 2.781,4.792 0.417,0.208 10 false B 1.031,4.583 1.448,4.792 0.417,0.208 10 false B 0.313,3.094 0.729,3.302 0.417,0.208 10 false V 0.313,0.698 0.729,0.906 0.417,0.208 10 false V

Result:
Result Proceed to
All conditions in table 1 are met. A
All conditions in table 2 are met.
Other than above. B


k.

Turn the power switch off.



A

B

4.CHECK BATTERY SMART UNIT
4.CHECK BATTERY SMART UNIT
NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance.


a.

2012/05 - 2013/12:


ii.

Measure the resistance according to the value(s) in the table below.

HINT:

It is only necessary to measure the resistance of the battery smart unit at the terminals which relate to the lower voltage battery block of pairs of battery blocks for which the difference in voltage in the Data List was 0.6 V or more.


A417508C02
1.156,2.229 1.594,2.521 0.438,0.292 1.885,2.229 2.323,2.521 0.438,0.292 2.563,2.24 3,2.531 0.438,0.292 3.271,2.25 3.708,2.542 0.438,0.292 0.344,0.115 1,0.729 0.656,0.615 10 false *a 1.271,2.271 1.854,2.615 0.583,0.344 10 false z23 2.01,2.271 2.594,2.615 0.583,0.344 10 false z22 2.667,2.281 3.25,2.625 0.583,0.344 10 false z27 3.385,2.302 3.969,2.646 0.583,0.344 10 false z26
*a Component without harness connected
(Battery Smart Unit)
- -


Standard Resistance (When Value of Battery Block Vol-V01 (VB1) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z26-13 (GA0) (-) - z26-9 (VA1) (+) Always 50 kΩ or higher
z26-9 (VA1) (-) - z26-5 (VA2) (+) Always 50 kΩ or higher
z26-5 (VA2) (-) - z26-1 (VA3) (+) Always 50 kΩ or higher
z26-1 (VA3) (-) - z26-14 (VA4) (+) Always 50 kΩ or higher
z26-14 (VA4) (-) - z26-10 (VA5) (+) Always 50 kΩ or higher
z26-10 (VA5) (-) - z26-6 (VA6) (+) Always 50 kΩ or higher
z26-6 (VA6) (-) - z26-2 (VA7) (+) Always 50 kΩ or higher
z26-13 (GA0) (-) -z26-2 (VA7) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V02 (VB2) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z26-2 (VA7) (-) - z26-15 (VA8) (+) Always 50 kΩ or higher
z26-15 (VA8) (-) - z26-11 (VA9) (+) Always 50 kΩ or higher
z26-11 (VA9) (-) - z26-7 (VA10) (+) Always 50 kΩ or higher
z26-7 (VA10) (-) - z26-16 (VA11) (+) Always 50 kΩ or higher
z26-16 (VA11) (-) - z26-12 (VA12) (+) Always 50 kΩ or higher
z26-12 (VA12) (-) - z26-8 (VA13) (+) Always 50 kΩ or higher
z26-8 (VA13) (-) - z26-4 (VA14) (+) Always 50 kΩ or higher
z26-2 (VA7) (-) - z26-4 (VA14) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V03 (VB3) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z27-11 (GA1) (-) - z27-6 (VA15) (+) Always 50 kΩ or higher
z27-6 (VA15) (-) - z27-1 (VA16) (+) Always 50 kΩ or higher
z27-1 (VA16) (-) - z27-12 (VA17) (+) Always 50 kΩ or higher
z27-12 (VA17) (-) - z27-7 (VA18) (+) Always 50 kΩ or higher
z27-7 (VA18) (-) - z27-2 (VA19) (+) Always 50 kΩ or higher
z27-2 (VA19) (-) - z27-13 (VA20) (+) Always 50 kΩ or higher
z27-13 (VA20) (-) - z27-8 (VA21) (+) Always 50 kΩ or higher
z27-11 (GA1) (-) - z27-8 (VA21) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V04 (VB4) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z27-8 (VA21) (-) - z27-3 (VA22) (+) Always 50 kΩ or higher
z27-3 (VA22) (-) - z27-14 (VA23) (+) Always 50 kΩ or higher
z27-14 (VA23) (-) - z27-9 (VA24) (+) Always 50 kΩ or higher
z27-9 (VA24) (-) - z27-4 (VA25) (+) Always 50 kΩ or higher
z27-4 (VA25) (-) - z27-15 (VA26) (+) Always 50 kΩ or higher
z27-15 (VA26) (-) - z27-10 (VA27) (+) Always 50 kΩ or higher
z27-10 (VA27) (-) - z27-5 (VA28) (+) Always 50 kΩ or higher
z27-8 (VA21) (-) - z27-5 (VA28) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V05 (VB5) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z22-11 (GA2) (-) - z22-6 (VA29) (+) Always 50 kΩ or higher
z22-6 (VA29) (-) - z22-1 (VA30) (+) Always 50 kΩ or higher
z22-1 (VA30) (-) - z22-12 (VA31) (+) Always 50 kΩ or higher
z22-12 (VA31) (-) - z22-7 (VA32) (+) Always 50 kΩ or higher
z22-7 (VA32) (-) - z22-2 (VA33) (+) Always 50 kΩ or higher
z22-2 (VA33) (-) - z22-13 (VA34) (+) Always 50 kΩ or higher
z22-13 (VA34) (-) - z22-8 (VA35) (+) Always 50 kΩ or higher
z22-11 (GA2) (-) - z22-8 (VA35) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V06 (VB6) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z22-8 (VA35) (-) - z22-3 (VA36) (+) Always 50 kΩ or higher
z22-3 (VA36) (-) - z22-14 (VA37) (+) Always 50 kΩ or higher
z22-14 (VA37) (-) - z22-9 (VA38) (+) Always 50 kΩ or higher
z22-9 (VA38) (-) - z22-4 (VA39) (+) Always 50 kΩ or higher
z22-4 (VA39) (-) - z22-15 (VA40) (+) Always 50 kΩ or higher
z22-15 (VA40) (-) - z22-10 (VA41) (+) Always 50 kΩ or higher
z22-10 (VA41) (-) - z22-5 (VA42) (+) Always 50 kΩ or higher
z22-8 (VA35) (-) - z22-5 (VA42) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V07 (VB7) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z23-13 (GA3) (-) - z23-9 (VA43) (+) Always 50 kΩ or higher
z23-9 (VA43) (-) - z23-5 (VA44) (+) Always 50 kΩ or higher
z23-5 (VA44) (-) - z23-1 (VA45) (+) Always 50 kΩ or higher
z23-1 (VA45) (-) - z23-14 (VA46) (+) Always 50 kΩ or higher
z23-14 (VA46) (-) - z23-10 (VA47) (+) Always 50 kΩ or higher
z23-10 (VA47) (-) - z23-6 (VA48) (+) Always 50 kΩ or higher
z23-6 (VA48) (-) - z23-2 (VA49) (+) Always 50 kΩ or higher
z23-13 (GA3) (-) - z23-2 (VA49) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V08 (VB8) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z23-2 (VA49) (-) - z23-15 (VA50) (+) Always 50 kΩ or higher
z23-15 (VA50) (-) - z23-11 (VA51) (+) Always 50 kΩ or higher
z23-11 (VA51) (-) - z23-7 (VA52) (+) Always 50 kΩ or higher
z23-7 (VA52) (-) - z23-16 (VA53) (+) Always 50 kΩ or higher
z23-16 (VA53) (-) - z23-12 (VA54) (+) Always 50 kΩ or higher
z23-12 (VA54) (-) - z23-8 (VA55) (+) Always 50 kΩ or higher
z23-8 (VA55) (-) - z23-4 (VA56) (+) Always 50 kΩ or higher
z23-2 (VA49) (-) - z23-4 (VA56) (+) Always 350 kΩ or higher


NOTICE:
·

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.

·

Read the resistance after the value has stabilized.

·

In order to avoid damaging the terminals of the battery smart unit, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery smart unit.




iii.

Install the battery smart unit.

Result:
Result Proceed to
All measured values were within specified range. A
Other than above. B




b.

2013/12 -:


ii.

Measure the resistance according to the value(s) in the table below.

HINT:

It is only necessary to measure the resistance of the battery smart unit at the terminals which relate to the lower voltage battery block of pairs of battery blocks for which the difference in voltage in the Data List was 0.6 V or more.


A417508C03
1.156,2.229 1.594,2.521 0.438,0.292 1.885,2.229 2.323,2.521 0.438,0.292 2.563,2.24 3,2.531 0.438,0.292 3.271,2.25 3.708,2.542 0.438,0.292 0.344,0.115 1,0.729 0.656,0.615 10 false *a 1.271,2.271 1.854,2.615 0.583,0.344 10 false z31 2.01,2.271 2.594,2.615 0.583,0.344 10 false z30 2.667,2.281 3.25,2.625 0.583,0.344 10 false z33 3.365,2.302 3.948,2.646 0.583,0.344 10 false z32
*a Component without harness connected
(Battery Smart Unit)
- -


Standard Resistance (When Value of Battery Block Vol-V01 (VB1) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z32-13 (GA0) (-) - z32-9 (VA1) (+) Always 50 kΩ or higher
z32-9 (VA1) (-) - z32-5 (VA2) (+) Always 50 kΩ or higher
z32-5 (VA2) (-) - z32-1 (VA3) (+) Always 50 kΩ or higher
z32-1 (VA3) (-) - z32-14 (VA4) (+) Always 50 kΩ or higher
z32-14 (VA4) (-) - z32-10 (VA5) (+) Always 50 kΩ or higher
z32-10 (VA5) (-) - z32-6 (VA6) (+) Always 50 kΩ or higher
z32-6 (VA6) (-) - z32-2 (VA7) (+) Always 50 kΩ or higher
z32-13 (GA0) (-) -z32-2 (VA7) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V02 (VB2) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z32-2 (VA7) (-) - z32-15 (VA8) (+) Always 50 kΩ or higher
z32-15 (VA8) (-) - z32-11 (VA9) (+) Always 50 kΩ or higher
z32-11 (VA9) (-) - z32-7 (VA10) (+) Always 50 kΩ or higher
z32-7 (VA10) (-) - z32-16 (VA11) (+) Always 50 kΩ or higher
z32-16 (VA11) (-) - z32-12 (VA12) (+) Always 50 kΩ or higher
z32-12 (VA12) (-) - z32-8 (VA13) (+) Always 50 kΩ or higher
z32-8 (VA13) (-) - z32-4 (VA14) (+) Always 50 kΩ or higher
z32-2 (VA7) (-) - z32-4 (VA14) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V03 (VB3) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z33-11 (GA1) (-) - z33-6 (VA15) (+) Always 50 kΩ or higher
z33-6 (VA15) (-) - z33-1 (VA16) (+) Always 50 kΩ or higher
z33-1 (VA16) (-) - z33-12 (VA17) (+) Always 50 kΩ or higher
z33-12 (VA17) (-) - z33-7 (VA18) (+) Always 50 kΩ or higher
z33-7 (VA18) (-) - z33-2 (VA19) (+) Always 50 kΩ or higher
z33-2 (VA19) (-) - z33-13 (VA20) (+) Always 50 kΩ or higher
z33-13 (VA20) (-) - z33-8 (VA21) (+) Always 50 kΩ or higher
z33-11 (GA1) (-) - z33-8 (VA21) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V04 (VB4) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z33-8 (VA21) (-) - z33-3 (VA22) (+) Always 50 kΩ or higher
z33-3 (VA22) (-) - z33-14 (VA23) (+) Always 50 kΩ or higher
z33-14 (VA23) (-) - z33-9 (VA24) (+) Always 50 kΩ or higher
z33-9 (VA24) (-) - z33-4 (VA25) (+) Always 50 kΩ or higher
z33-4 (VA25) (-) - z33-15 (VA26) (+) Always 50 kΩ or higher
z33-15 (VA26) (-) - z33-10 (VA27) (+) Always 50 kΩ or higher
z33-10 (VA27) (-) - z33-5 (VA28) (+) Always 50 kΩ or higher
z33-8 (VA21) (-) - z33-5 (VA28) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V05 (VB5) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z30-11 (GA2) (-) - z30-6 (VA29) (+) Always 50 kΩ or higher
z30-6 (VA29) (-) - z30-1 (VA30) (+) Always 50 kΩ or higher
z30-1 (VA30) (-) - z30-12 (VA31) (+) Always 50 kΩ or higher
z30-12 (VA31) (-) - z30-7 (VA32) (+) Always 50 kΩ or higher
z30-7 (VA32) (-) - z30-2 (VA33) (+) Always 50 kΩ or higher
z30-2 (VA33) (-) - z30-13 (VA34) (+) Always 50 kΩ or higher
z30-13 (VA34) (-) - z30-8 (VA35) (+) Always 50 kΩ or higher
z30-11 (GA2) (-) - z30-8 (VA35) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V06 (VB6) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z30-8 (VA35) (-) - z30-3 (VA36) (+) Always 50 kΩ or higher
z30-3 (VA36) (-) - z30-14 (VA37) (+) Always 50 kΩ or higher
z30-14 (VA37) (-) - z30-9 (VA38) (+) Always 50 kΩ or higher
z30-9 (VA38) (-) - z30-4 (VA39) (+) Always 50 kΩ or higher
z30-4 (VA39) (-) - z30-15 (VA40) (+) Always 50 kΩ or higher
z30-15 (VA40) (-) - z30-10 (VA41) (+) Always 50 kΩ or higher
z30-10 (VA41) (-) - z30-5 (VA42) (+) Always 50 kΩ or higher
z30-8 (VA35) (-) - z30-5 (VA42) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V07 (VB7) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z31-13 (GA3) (-) - z31-9 (VA43) (+) Always 50 kΩ or higher
z31-9 (VA43) (-) - z31-5 (VA44) (+) Always 50 kΩ or higher
z31-5 (VA44) (-) - z31-1 (VA45) (+) Always 50 kΩ or higher
z31-1 (VA45) (-) - z31-14 (VA46) (+) Always 50 kΩ or higher
z31-14 (VA46) (-) - z31-10 (VA47) (+) Always 50 kΩ or higher
z31-10 (VA47) (-) - z31-6 (VA48) (+) Always 50 kΩ or higher
z31-6 (VA48) (-) - z31-2 (VA49) (+) Always 50 kΩ or higher
z31-13 (GA3) (-) - z31-2 (VA49) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V08 (VB8) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z31-2 (VA49) (-) - z31-15 (VA50) (+) Always 50 kΩ or higher
z31-15 (VA50) (-) - z31-11 (VA51) (+) Always 50 kΩ or higher
z31-11 (VA51) (-) - z31-7 (VA52) (+) Always 50 kΩ or higher
z31-7 (VA52) (-) - z31-16 (VA53) (+) Always 50 kΩ or higher
z31-16 (VA53) (-) - z31-12 (VA54) (+) Always 50 kΩ or higher
z31-12 (VA54) (-) - z31-8 (VA55) (+) Always 50 kΩ or higher
z31-8 (VA55) (-) - z31-4 (VA56) (+) Always 50 kΩ or higher
z31-2 (VA49) (-) - z31-4 (VA56) (+) Always 350 kΩ or higher


NOTICE:
·

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.

·

Read the resistance after the value has stabilized.

·

In order to avoid damaging the terminals of the battery smart unit, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery smart unit.




iii.

Install the battery smart unit.

Result:
Result Proceed to
All measured values were within specified range. A
Other than above. B





A

B

5.REPLACE BATTERY SMART UNIT