Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › 2014.11–2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301574 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A84-123  Hybrid Battery Pack Cooling Fan 1 Control Circuit Low  


DESCRIPTION

The speed of the battery cooling blower assembly is controlled by the power management control ECU. Battery cooling blower assembly power is supplied when the FCTL terminal of the power management control ECU turns on the battery blower relay. The power management control ECU sends command signals (SI) to the battery cooling blower assembly to get the fan speed corresponding to the HV battery temperature. Information about the voltage applied to the battery cooling blower assembly (VM) is sent to the power management control ECU as a monitor signal using serial communication via the battery smart unit.

A260101E03
0.487,0.093 2.559,0.256 2.073,0.163 10 Battery Cooling Blower Assembly 2.795,0.958 3.895,1.121 1.100,0.163 10 Command Signal 2.893,3.196 3.799,3.359 0.906,0.163 10 Monitor Signal 4.709,0.433 5.976,0.751 1.267,0.318 10 Power Management Control ECU 4.779,2.363 5.933,2.514 1.154,0.151 10 Battery Smart Unit 3.897,1.729 5.280,1.892 1.383,0.163 10 Serial Communication


DTC No. INF Code DTC Detection Condition Trouble Area
P0A84 123 When the output voltage of the battery cooling blower assembly (VM) is too low compared to the target control voltage range (1 trip detection)
·

Wire harness or connector

·

No. 2 integration relay

·

Battery cooling blower assembly

·

Battery smart unit

·

Power management control ECU



WIRING DIAGRAM

A255044E22
0.635,4.698 3.24,4.896 2.604,0.198 10 false Auxiliary Battery 0.521,3.885 1.135,4.083 0.615,0.198 10 false MAIN 0.51,3.115 1.281,3.313 0.771,0.198 10 false P/I 1 0.844,2.219 1,2.417 0.156,0.198 10 false 1 0.802,2.396 1.115,2.594 0.313,0.198 10 false 1C 1.135,2.833 2.75,3.083 1.615,0.25 10 false No. 2 Integration Relay 1.396,1.885 2.625,2.083 1.229,0.198 10 false BATT FAN 1.625,1.25 2.854,1.448 1.229,0.198 10 false BATT FAN 2.688,0.427 2.844,0.625 0.156,0.198 10 false 7 2.688,0.781 2.844,0.979 0.156,0.198 10 false 8 2.625,0.604 2.938,0.802 0.313,0.198 10 false 1A 2.625,0.948 2.938,1.146 0.313,0.198 10 false 1A 5.813,0.427 5.969,0.625 0.156,0.198 10 false 4 3.323,1.24 3.479,1.438 0.156,0.198 10 false 1 3.333,1.688 3.49,1.885 0.156,0.198 10 false 4 4.448,1.229 4.604,1.427 0.156,0.198 10 false 3 4.448,1.698 4.604,1.896 0.156,0.198 10 false 2 3.542,2.146 4.969,2.635 1.427,0.49 10 false Battery Cooling Blower Assembly 3.5,1.333 3.958,1.531 0.458,0.198 10 false IG0 3.49,1.792 4.104,1.99 0.615,0.198 10 false GND0 4.146,1.344 4.604,1.542 0.458,0.198 10 false SI0 4.073,1.802 4.531,2 0.458,0.198 10 false VM0 4.49,2.917 4.646,3.115 0.156,0.198 10 false 8 4.5,3.24 4.656,3.438 0.156,0.198 10 false 2 4.5,3.563 4.656,3.76 0.156,0.198 10 false 3 4.156,3.021 4.469,3.219 0.313,0.198 10 false VM 4.031,3.333 4.646,3.531 0.615,0.198 10 false BTH+ 4.052,3.646 4.667,3.844 0.615,0.198 10 false BTH- 3.063,4.073 3.521,4.271 0.458,0.198 10 false L144 3.479,4.073 4.792,4.323 1.313,0.25 10 false Battery Smart Unit 5.729,0.615 6.188,0.813 0.458,0.198 10 false A21 5.74,1.354 6.198,1.552 0.458,0.198 10 false A21 5.76,1.167 6.073,1.365 0.313,0.198 10 false 29 5.771,3.333 6.083,3.531 0.313,0.198 10 false L5 5.771,3.667 6.083,3.865 0.313,0.198 10 false L5 5.771,4.01 6.083,4.208 0.313,0.198 10 false L5 5.771,4.375 6.083,4.573 0.313,0.198 10 false L6 5.771,3.167 6.083,3.365 0.313,0.198 10 false 32 5.781,3.5 6.094,3.698 0.313,0.198 10 false 33 5.813,3.833 6.125,4.031 0.313,0.198 10 false 5 5.813,4.198 6.125,4.396 0.313,0.198 10 false 5 6.104,3.333 6.719,3.531 0.615,0.198 10 false BTH+ 6.104,3.667 6.719,3.865 0.615,0.198 10 false BTH- 6.104,4.01 6.563,4.208 0.458,0.198 10 false E01 6.104,4.365 6.563,4.563 0.458,0.198 10 false E02 6.115,0.615 6.729,0.813 0.615,0.198 10 false FCTL 6.125,1.354 6.583,1.552 0.458,0.198 10 false SI0 3.25,2.146 3.563,2.344 0.313,0.198 10 false S30 5.802,4.76 7.063,5.375 1.26,0.615 10 false Power Management Control ECU

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

2.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.


d.

Select air volume mode 6 in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.

NOTICE:

If the Active Test cannot be performed, skip it and proceed to the next step to check fan operates and air is sucked. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.


HINT:

Change the air volume mode slowly. The battery cooling blower assembly speed will only increase in 1 mode steps, even if the air volume mode is rapidly changed from 1 to 6.



e.

Check that the fan operates and air is sucked into the inlet duct.

HINT:

The cooling fan may not stop even when turning the cooling fan off in the "Driving the Battery Cooling Fan" Active Test. This is due to HV system control and not a malfunction.


OK:

The fan operates.



f.

Turn the power switch off.



OK

3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

NG

7.CHECK FUSE (BATT FAN)
3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the front seat assembly RH.



c.

Turn over the front floor carpet.


d.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


e.

Disconnect the S30 battery cooling blower assembly connector.


f.
U190659E02
2.51,0.51 2.865,0.667 0.354,0.156 10 false L144

Disconnect the L144 battery smart unit connector.


g.
U190622E02
1.875,0.854 2.531,0.604 true 0.417,3.979 0.948,3.781 true 1.083,0.031 1.25,0.271 0.167,0.24 10 false *a 1.26,1.708 1.427,1.948 0.167,0.24 10 false *b 0.896,0.833 1.198,1.01 0.302,0.177 10 false S30 2.594,0.5 2.927,0.667 0.333,0.167 10 false VM0 0.167,3.906 0.5,4.073 0.333,0.167 10 false VM 1.771,3.479 2.156,3.656 0.385,0.177 10 false L144

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
S30-2 (VM0) - L144-8 (VM) Power switch off Below 1 Ω
S30-2 (VM0) or L144-8 (VM) - Body ground Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Battery Smart Unit)


h.

Connect the cable to the negative (-) auxiliary battery terminal.


i.

Turn the power switch on (IG).


j.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
S30-2 (VM0) - Body ground Power switch on (IG) Below 1 V


NOTICE:

If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.


HINT:

As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.

Check that each connector between the battery voltage sensor and battery cooling blower assembly is not loose or disconnected.



k.

Turn the power switch off.


l.

Disconnect the cable from the negative (-) auxiliary battery terminal.


m.

Reconnect the L144 battery smart unit connector.


n.

Reconnect the S30 battery cooling blower assembly connector.


o.

Install the No. 1 hybrid battery shield sub-assembly.


p.

Install the front floor carpet.


q.

Install the front seat assembly RH.



OK

4.READ VALUE USING GTS (VMF FAN MOTOR VOLTAGE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.READ VALUE USING GTS (VMF FAN MOTOR VOLTAGE)
a.

Remove the front seat assembly RH.



b.

Turn over the front floor carpet.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Connect the GTS to the DLC3.


e.

Turn the power switch on (IG).


f.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.



h.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.


i.

Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / VMF Fan Motor Voltage 1.


j.

Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.

NOTICE:

If the Active Test cannot be performed, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the hybrid vehicle control ECU assembly sends a command to operate the battery cooling fan assembly.



k.
U190644E02
2.792,0.385 2.031,1.198 true 2.792,0.771 2.031,1.333 true 0.177,0.104 0.344,0.26 0.167,0.156 10 false *a 1.448,0.635 1.615,0.792 0.167,0.156 10 false *b 2.823,0.271 3.125,0.427 0.302,0.156 10 false VM0 2.823,0.625 3.229,0.781 0.406,0.156 10 false GND0 0.354,1.865 0.635,2.021 0.281,0.156 10 false S30

While the cooling fan is operating, compare the value in the Data List (Cooling Fan Frequency1) with the frequency value that was actually measured at the battery cooling blower assembly connector.

Standard:
Tester Connection Condition
S30-2 (VM0) - S30-4 (GND0) Battery cooling blower assembly is operating


Text in Illustration
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Battery Cooling Blower Assembly)

Result:
Result Proceed to
The value in the Data List (VMF Fan Motor Voltage 1) and the actual measurement value at the battery cooling blower assembly connector are below 1 V. A
Other than above. B


HINT:

Compare the values in each air volume mode (1 to 6). If the Active Test cannot be performed, compare the values only in the current air volume mode.



l.

Turn the power switch off.


m.

Install the front floor carpet.


n.

Install the front seat assembly RH.



A

5.CHECK BATTERY SMART UNIT

B

6.CHECK BATTERY SMART UNIT (VOLTAGE)
5.CHECK BATTERY SMART UNIT
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.
U190659E02
2.51,0.51 2.865,0.667 0.354,0.156 10 false L144

Disconnect the L144 battery smart unit connector.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Connect the GTS to the DLC3.


f.

Turn the power switch on (IG).


g.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.


h.

Select air volume mode 6 in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.

NOTICE:

If the Active Test cannot be performed, skip it and proceed to the next step to check fan operates and air is sucked. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.



i.
U190650E02
1.26,1.5 0.865,1.75 true 1.281,1.333 0.875,1.021 true 0.177,0.073 0.365,0.313 0.188,0.24 10 false *a 0.552,0.938 1.052,1.188 0.5,0.25 10 false GND 1.927,1.281 2.281,1.448 0.354,0.167 10 false L144 0.625,1.698 1.125,1.948 0.5,0.25 10 false VM

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
L144-8 (VM) - L144-4 (GND) Battery cooling blower is operating 1 V or more


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)

NOTICE:

If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.



j.

Turn the power switch off.


k.

Disconnect the cable from the negative (-) auxiliary battery terminal.


l.

Reconnect the L144 battery smart unit connector.


m.

Install the No. 1 hybrid battery shield sub-assembly.



A

NG

REPLACE BATTERY COOLING BLOWER ASSEMBLY

6.CHECK BATTERY SMART UNIT (VOLTAGE)
a.

Remove the front seat assembly RH.



b.

Turn over the front floor carpet.


c.

Connect the GTS to the DLC3.


d.

Turn the power switch on (IG).


e.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.


f.

Enter the following menus: All Data / VMF Fan Motor Voltage 1.


g.

Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.

NOTICE:

If the Active Test cannot be performed, skip it and proceed to the next step to check voltage. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.



h.
U190644E02
2.792,0.385 2.031,1.198 true 2.792,0.771 2.031,1.333 true 0.177,0.104 0.344,0.26 0.167,0.156 10 false *a 1.448,0.635 1.615,0.792 0.167,0.156 10 false *b 2.823,0.271 3.125,0.427 0.302,0.156 10 false VM0 2.823,0.625 3.229,0.781 0.406,0.156 10 false GND0 0.354,1.865 0.635,2.021 0.281,0.156 10 false S30

While the cooling fan is operating, compare the value in the data list (VMF Fan Motor Voltage 1) with the voltage value that was actually measured at the battery cooling blower assembly connector.

Standard:
Tester Connection Condition Specified Condition
S30-2 (VM0) - S30-4 (GND0) Battery cooling blower is operating Difference between the value in the Data List (VMF Fan Motor Voltage 1) and the actual measurement value is 1 V or less.


Text in Illustration
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Front view of wire harness connector
(to Battery Cooling Blower Assembly)


HINT:

Compare the values in each air volume mode (1 to 6). If the active test cannot be performed, compare the values only in the current air volume mode.


i.

Turn the power switch off.


j.

Install the front floor carpet.


k.

Install the front seat assembly RH.



OK

REPLACE BATTERY COOLING BLOWER ASSEMBLY

NG

7.CHECK FUSE (BATT FAN)
a.

Remove the BATT FAN fuse from the engine room relay block and junction block assembly


b.
A253700E01
0.157,0.102 0.378,0.286 0.221,0.184 10 *1 3.074,1.059 3.294,1.242 0.221,0.184 10 *2 2.481,1.272 3.053,1.151 false

Measure the resistance of the BATT FAN fuse.

Standard Resistance:
Tester Connection Condition Specified Condition
BATT FAN fuse Always Below 1 Ω

Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 BATT FAN Fuse



c.

Install the BATT FAN fuse.



OK

8.CHECK NO. 2 INTEGRATION RELAY (BATT FAN)

NG

19.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BATTERY COOLING BLOWER ASSEMBLY)
8.CHECK NO. 2 INTEGRATION RELAY (BATT FAN)
a.

Remove the No. 2 integration relay from the engine room relay block and junction block assembly.


b.

Measure the resistance according to the value(s) in the table below.

U110592E04
3.917,0 4.25,0.188 0.333,0.188 10 false *1 0.281,0.542 0.615,0.729 0.333,0.188 10 false *1 0.51,1.063 0.74,1.229 0.229,0.167 10 false 1C 2.083,1.063 2.313,1.229 0.229,0.167 10 false 1A 3.198,0.521 3.427,0.688 0.229,0.167 10 false 1C 6.625,0.219 6.854,0.385 0.229,0.167 10 false 1A 3.406,1.021 3.656,1.24 0.25,0.219 10 false 1 6.563,0.583 6.813,0.802 0.25,0.219 10 false 5 6.563,1.021 6.813,1.24 0.25,0.219 10 false 8 6.563,1.292 6.813,1.51 0.25,0.219 10 false 7 6.563,1.813 6.813,2.031 0.25,0.219 10 false 6 4.146,1.198 4.479,1.385 0.333,0.188 10 false *2 4.927,1.625 5.26,1.813 0.333,0.188 10 false *3

Text in Illustration
*1 No. 2 Integration Relay *2 BATT FAN Fuse
*3 BATT FAN Relay - -

Standard Resistance:
Tester Connection Condition Specified Condition
1C-1 - 1A-8 Battery voltage is applied across terminals 1A-6 and 1A-7 Below 1 Ω
No battery voltage is applied across terminals 1A-6 and 1A-7 10 kΩ or higher



c.

Install the No. 2 integration relay.



OK

9.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BATTERY COOLING BLOWER ASSEMBLY) (VOLTAGE)

NG

9.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BATTERY COOLING BLOWER ASSEMBLY) (VOLTAGE)
a.

Remove the front seat assembly RH.



b.

Turn over the front floor carpet.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Connect the GTS to the DLC3.


e.

Turn the power switch on (IG).


f.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.



h.
U190645E03
1.208,0.875 1.844,1.156 true 2.021,1.375 2.469,1.823 true 0.177,0.104 0.344,0.26 0.167,0.156 10 false *a 1.5,0.635 1.667,0.792 0.167,0.156 10 false *b 0.979,0.781 1.25,0.938 0.271,0.156 10 false IG0 0.344,1.865 0.625,2.021 0.281,0.156 10 false S30 2.396,1.885 2.938,2.313 0.542,0.427 10 false GND0

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
S30-1 (IG0) - S30-4 (GND0) Power switch on (IG) 11 to 14 V


Text in Illustration
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Front view of wire harness connector
(to Battery Cooling Blower Assembly)

HINT:

Measure the voltage on the wire side of the connector that is part of the battery cooling blower.



i.

Turn the power switch off.


j.

Install the front floor carpet.


k.

Install the front seat assembly RH.



OK

10.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - POWER MANAGEMENT CONTROL ECU)

NG

14.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER ASSEMBLY - BODY GROUND)
10.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - POWER MANAGEMENT CONTROL ECU)
a.

Remove the front seat assembly RH.



b.

Turn over the front floor carpet.


c.

Disconnect the S30 battery cooling blower assembly connector.


d.

Disconnect the A21 power management control ECU connector.


e.
U190587E02
1.635,0.927 0.781,1.177 false 1.531,3.698 2.156,3.99 false 0.958,0.083 1.115,0.365 0.156,0.281 10 false *a 0.521,1.094 1.021,1.323 0.5,0.229 10 false SI0 0.688,1.552 0.844,1.833 0.156,0.281 10 false *b 2.208,3.938 2.708,4.167 0.5,0.229 10 false SI0 2.406,0.646 2.708,0.813 0.302,0.167 10 false S30 1.917,3.333 2.219,3.5 0.302,0.167 10 false A21

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
S30-3 (SI0) - A21-29 (SI0) Power switch off Below 1 Ω
S30-3 (SI0) or A21-29 (SI0) - Body ground Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Power Management Control ECU)


f.

Turn the power switch on (IG).


g.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
S30-3 (SI0) - Body ground Power switch on (IG) Below 1 V



NOTICE:

If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.


h.

Turn the power switch off.


i.

Reconnect the A21 power management control ECU connector.


j.

Reconnect the S30 battery cooling blower assembly connector.


k.

Install the front floor carpet.


l.

Install the front seat assembly RH.



OK

11.CHECK POWER MANAGEMENT CONTROL ECU

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

11.CHECK POWER MANAGEMENT CONTROL ECU
a.

Remove the power management control ECU (See page Power Source / Network>POWER DISTRIBUTION>POWER MANAGEMENT CONTROL ECU>COMPONENTS).


b.
A409192C46
0.594,0.354 1.01,0.615 0.417,0.26 1.875,0.396 2.292,0.656 0.417,0.26 0.969,1.76 0.969,1.271 true 2.49,1.875 2.25,1.875 2.25,1.875 1.896,1.031 true 0.167,0.052 0.531,0.417 0.365,0.365 10 false *a 0.854,1.813 1.51,2.125 0.656,0.313 10 false SI0 2.542,1.813 3.198,2.125 0.656,0.313 10 false E01 0.698,0.417 1.354,0.729 0.656,0.313 10 false A21 1.99,0.448 2.646,0.76 0.656,0.313 10 false L5
*a Component without harness connected
(Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Specified Condition
A21-29 (SI0) - L5-5 (E01) 10 kΩ or higher



c.

Install the power management control ECU.



OK

12.CHECK POWER MANAGEMENT CONTROL ECU (SI0 VOLTAGE)

NG

12.CHECK POWER MANAGEMENT CONTROL ECU (SI0 VOLTAGE)
a.

Turn the power switch on (IG).


b.
A413847C14
1.844,0.979 2.271,1.271 0.427,0.292 0.563,0.969 0.99,1.26 0.427,0.292 0.635,2.917 0.958,1.917 true 2.458,2.917 1.885,1.698 true 1.979,1.042 2.438,1.24 0.458,0.198 10 false L5 0.542,2.958 0.979,3.292 0.438,0.333 10 false SI0 2.396,2.948 2.833,3.281 0.438,0.333 10 false E01 0.135,0.073 0.802,0.729 0.667,0.656 10 false *a 0.635,1.021 1.094,1.219 0.458,0.198 10 false A21
*a Component with harness connected
(Power Management Control ECU)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A21-29 (SI0) - L5-5 (E01) Power switch on (IG) 4.5 to 5.5 V



c.

Turn the power switch off.



OK

13.CHECK BATTERY COOLING BLOWER ASSEMBLY

NG

REPLACE BATTERY COOLING BLOWER ASSEMBLY

13.CHECK BATTERY COOLING BLOWER ASSEMBLY
a.

Remove the front seat assembly RH.



b.

Turn over the front floor carpet.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Connect the GTS to the DLC3.


e.

Turn the power switch on (IG).


f.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.



h.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.


i.

Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.

NOTICE:

If the Active Test cannot be performed, skip it and proceed to the next step to check fan operates and air is sucked. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.



j.
U190647E02
1.031,0.594 1.823,1.333 true 2.792,0.771 2.031,1.333 true 0.177,0.104 0.344,0.26 0.167,0.156 10 false *a 1.448,0.646 1.615,0.802 0.167,0.156 10 false *b 0.792,0.479 1.333,0.875 0.542,0.396 10 false SI0 2.823,0.625 3.229,0.781 0.406,0.156 10 false GND0 0.365,1.865 0.646,2.021 0.281,0.156 10 false S30

Connect an oscilloscope to the S30 battery cooling blower assembly connector and check the waveform.

Item Content
Tester Connection S30-3 (SI0) - S30-4 (GND0)
Equipment Setting 10 V/DIV., 1 ms/DIV.
Condition Power switch on (IG) during Active Test

Text in Illustration
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Battery Cooling Blower Assembly)


HINT:
·

Perform this inspection with the battery cooling blower assembly connector connected.

·

If DTCs are output after the check, clear the DTCs using the GTS.



k.

Turn the power switch off.


l.

Install the front floor carpet.


m.

Install the front seat assembly RH.


A284431E07
0.125,0.135 0.438,0.292 0.313,0.156 10 false *a 2.938,1.01 3.292,1.177 0.354,0.167 10 false GND

Text in Illustration
*a Waveform 1

Result:
Result Proceed to
Normal (The pulse output of waveform 1) A
No pulse generation B



A

REPLACE BATTERY COOLING BLOWER ASSEMBLY

B

14.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER ASSEMBLY - BODY GROUND)
a.

Remove the front seat assembly RH.



b.
U190645C03
2.021,1.375 2.469,1.823 true 0.177,0.104 0.344,0.26 0.167,0.156 10 false *a 1.5,0.635 1.667,0.792 0.167,0.156 10 false *b 0.344,1.865 0.625,2.021 0.281,0.156 10 false S30 2.427,1.875 2.927,2.25 0.5,0.375 10 false GND0
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Front view of wire harness connector
(to Battery Cooling Blower Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
S30-4 (GND0) - Body ground Power switch off Below 1 Ω



c.

Install the front seat assembly RH.



OK

15.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - POWER MANAGEMENT CONTROL ECU)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

15.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - POWER MANAGEMENT CONTROL ECU)
a.

Disconnect the A21 power management control ECU connector.


b.

Remove the No. 2 integration relay.


c.

Measure the resistance according to the value(s) in the table below.

A398187E01
2.833,1.833 3.25,2.083 0.417,0.25 3.917,1.833 4.333,2.083 0.417,0.25 4.781,2.063 5.365,1.927 false 0.271,0.177 0.583,0.375 0.313,0.198 10 false *a 3.833,0.188 4.146,0.385 0.313,0.198 10 false *b 2.948,1.865 3.26,2.063 0.313,0.198 10 false 1A 4,1.865 4.313,2.063 0.313,0.198 10 false A21 5.406,1.844 5.906,2.073 0.5,0.229 10 false FCTL

Standard Resistance:
Tester Connection Condition Specified Condition
1A-7 - A21-4 (FCTL) Power switch off Below 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to No. 2 Integration Relay)
*b Rear view of wire harness connector
(to Power Management Control ECU)

NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.



d.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A21-4 (FCTL) - Body ground Power switch off Below 1 V
Power switch on (IG) Below 1 V


NOTICE:

If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.



e.

Turn the power switch off.


f.

Reconnect the A21 power management control ECU connector.


g.

Install the No. 2 integration relay.



OK

16.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

16.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
a.

Disconnect the L5 power management control ECU connector.


b.
U154264E03
1.885,2.656 1.333,2.958 true 0.573,0.51 1,0.802 0.427,0.292 10 false *a 2.542,2.625 2.854,2.885 0.313,0.26 10 false L5 1.042,2.896 1.427,3.104 0.385,0.208 10 false E01

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L5-5 (E01) - Body ground Power switch off Below 1 Ω


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)

NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.



c.

Reconnect the L5 power management control ECU connector.



OK

17.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

17.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
a.

Disconnect the L6 power management control ECU connector.


b.
U154265E03
2.521,2.479 1.646,2.667 true 0.583,0.458 1,0.708 0.417,0.25 10 false *a 3.073,2.427 3.333,2.656 0.26,0.229 10 false L6 1.333,2.583 1.646,2.781 0.313,0.198 10 false E02

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L6-5 (E02) - Body ground Power switch off Below 1 Ω


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)

NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.



c.

Reconnect the L6 power management control ECU connector.



OK

18.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BATTERY COOLING BLOWER ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

18.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BATTERY COOLING BLOWER ASSEMBLY)
a.

Remove the No. 2 integration relay.


b.

Remove the front seat assembly RH.



c.

Turn over the front floor carpet.


d.

Disconnect the S30 battery cooling blower assembly connector.


e.
U190617E02
1.604,0.99 0.771,0.823 true 0.771,0.042 0.948,0.281 0.177,0.24 10 false *a 2.365,0.792 2.656,1 0.292,0.208 10 false S30 0.542,0.719 0.958,0.958 0.417,0.24 10 false IG0 0.729,1.906 0.906,2.146 0.177,0.24 10 false *b 2.625,3.969 2.917,4.177 0.292,0.208 10 false 1A

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1A-8 - S30-1 (IG0) Power switch off Below 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)
*b Front view of wire harness connector
(to No. 2 Integration Relay)


NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.


f.

Reconnect the S30 battery cooling blower assembly connector.


g.

Install the front floor carpet.


h.

Install the front seat assembly RH.


i.

Install the No. 2 integration relay.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

19.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BATTERY COOLING BLOWER ASSEMBLY)
a.

Remove the No. 2 integration relay.


b.

Remove the front seat assembly RH.



c.

Turn over the front floor carpet.


d.

Disconnect the S30 battery cooling blower assembly connector.


e.
U190617E02
1.604,0.99 0.771,0.823 true 0.771,0.042 0.948,0.281 0.177,0.24 10 false *a 2.365,0.792 2.656,1 0.292,0.208 10 false S30 0.542,0.719 0.958,0.958 0.417,0.24 10 false IG0 0.729,1.906 0.906,2.146 0.177,0.24 10 false *b 2.625,3.969 2.917,4.177 0.292,0.208 10 false 1A

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
S30-1 (IG0) - Terminals other than 1A-8 and body ground Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)
*b Front view of wire harness connector
(to No. 2 Integration Relay)


NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.


f.

Reconnect the S30 battery cooling blower assembly connector.


g.

Install the front floor carpet.


h.

Install the front seat assembly RH.


i.

Install the No. 2 integration relay.



OK

20.CHECK BATTERY COOLING BLOWER ASSEMBLY

NG

21.REPAIR OR REPLACE HARNESS OR CONNECTOR
20.CHECK BATTERY COOLING BLOWER ASSEMBLY
a.

Remove the front seat assembly RH.



b.

Turn over the front floor carpet.


c.

Disconnect the S30 battery cooling blower assembly connector.


d.
U190598E02
1.792,1.146 2.417,0.656 true 1.51,1.344 0.906,1.625 true 0.177,0.094 0.344,0.302 0.167,0.208 10 false *a 0.635,0.625 0.917,0.813 0.281,0.188 10 false S30 2.458,0.531 2.75,0.74 0.292,0.208 10 false IG0 0.51,1.563 0.948,1.771 0.438,0.208 10 false GND0

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
S30-1(IG0) - S30-4(GND0) and body ground Power switch off 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Battery Cooling Blower Assembly)


NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.


e.

Reconnect the S30 battery cooling blower assembly connector.


f.

Install the front floor carpet.


g.

Install the front seat assembly RH.



OK

REPLACE FUSE (BATT FAN)

NG

22.REPLACE BATTERY COOLING BLOWER ASSEMBLY
21.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (BATT FAN)

22.REPLACE BATTERY COOLING BLOWER ASSEMBLY

NEXT

REPLACE FUSE (BATT FAN)