HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P308A-123  Hybrid Battery Voltage Sensor All Circuits Low  


DESCRIPTION

Refer to the description for DTC P0A80-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A80-123).

DTC No. INF Code DTC Detection Condition Trouble Area
P308A 123 When the voltage of all battery blocks becomes less than 2.8 V (open) for each connector
(1 trip detection)
·

HV battery

·

Battery smart unit



HINT:

Values smaller than 2.8 V may not be shown in the Data List because a fail-safe value is substituted.



CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of HV battery, make sure to return them through an authorized collection agent who is capable of handling them safely. If they are returned via the manufacturer specified route, they will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)

A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)

A

3.CHECK CONNECTOR CONNECTION CONDITION (BATTERY SMART UNIT CONNECTOR)

B

3.CHECK CONNECTOR CONNECTION CONDITION (BATTERY SMART UNIT CONNECTOR)

OK

4.REPLACE BATTERY SMART UNIT

NG

CONNECT SECURELY

4.REPLACE BATTERY SMART UNIT

NEXT

5.CLEAR DTC (HV)
6.RECONFIRM DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Read output DTCs (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).

Result:
Result Proceed to
P308A-123 is not output A
P308A-123 is output B



e.

Turn the power switch off.



A

RETURNS TO NORMAL OPERATION