| Detection Item | Symptom | Trouble Area |
|---|---|---|
| Main Body ECU Communication Stop Mode | Either condition is met:
·
|
·
Main body ECU (multiplex network body ECU) branch line or connector ·
Power source circuit of main body ECU (multiplex network body ECU) ·
Main body ECU (multiplex network body ECU) ground circuit ·
Main body ECU (multiplex network body ECU) |
Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output (See page Power Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (w/ Central Gateway ECU)>HOW TO PROCEED WITH TROUBLESHOOTING).
After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
DTC check procedure: Turn the power switch on (IG) and wait at least 20 seconds.
After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed (See page Power Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (w/ Central Gateway ECU)>DIAGNOSIS SYSTEM).
Inspect the fuses for circuits related to this system before performing the following procedure.
Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.
When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the L201 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to Main Body ECU (Multiplex Network Body ECU)) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L201-14 (CANH) - L201-13 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
OK
NG
Remove the main body ECU (multiplex network body ECU) (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to Instrument Panel Junction Block Assembly) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| MB-11 (GND1) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
Perform this inspection with the wire harness connected to the instrument panel junction block assembly.
Reconnect the cable to the negative (-) auxiliary battery terminal.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| MB-30 (BECU) - Body ground | Power switch off | 11 to 14 V |
| MB-29 (ACC) - Body ground | Power switch on (ACC) | 11 to 14 V |
| MB-32 (IG) - Body ground | Power switch on (IG) | 11 to 14 V |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (BECU) | B |
| NG (ACC) | C |
| NG (IG) | D |
| NG (GND1) | E |
A
B
C
D
E
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the 2C instrument panel junction block assembly connector.
Reconnect the cable to the negative (-) auxiliary battery terminal.
Measure the voltage according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to Instrument Panel Junction Block Assembly) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2C-18 (BECU) - Body ground | Power switch off | 11 to 14 V |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the 2B instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to Instrument Panel Junction Block Assembly) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2B-4 (GND1) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
| 2B-6 (GND1) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
OK
NG